PRE-COATED MERCURY FILM ON GLASSY-CARBON ELECTRODE FOR THE SIMULTANEOUS DETERMINATION OF Cu2+, Zn2+, Cd2+, AND Pb2+ IN WATER

被引:1
|
作者
Pei, Jingxuan [1 ]
Yu, Xiang [1 ]
Liu, Xingju [2 ]
Zhang, Chao [3 ]
机构
[1] Univ Geosci Beijing, Sch Mat Sci & Technol, Beijing Key Lab Mat Utilisat Nonmetall Minerals, Natl Lab Mineral Mat, 29 Xueyuan Rd, Beijing 100083, Peoples R China
[2] China Univ Geosci Beijing, Sch Engn & Technol, 29 Xueyuan Rd, Beijing 100083, Peoples R China
[3] Univ Sci & Technol Beijing, Sch Mech Engn, 1 North Ring Rd, Tianjin 100083, Peoples R China
来源
STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA | 2019年 / 64卷 / 03期
基金
中国国家自然科学基金;
关键词
Glassy-Carbon Electrode; Mercury Film; Heavy Metal Ions; Anodic Stripping Voltammetry; STRIPPING VOLTAMMETRIC DETERMINATION; CU(II); LEAD; CADMIUM; CD(II); ZN(II);
D O I
10.24193/subbchem.2019.3.17
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A mercury film was pre-coated on glassy-carbon electrodes to improve the precision and detection limit of the electrodes in anodic stripping voltammetry. A mixed solution containing 0.1 mg/l Zn2+, 0.01 mg/l Pb2+, 0.01 mg/l Cd2+, and 0.5 mg/l Cu2+ was used to investigate the simultaneous detection of these ions by the electrode. The influence of the base solution pH and the accumulation time on the electrochemical reactions of Cu2+, Zn2+, Cd2+, and Pb2+ were investigated, as well as the effect of the concentration of the film coating solution and the number of mercury coating step on the stripping signals of the four ions. Optimizing the parameters of the pre-coated mercury film improved the precision of the glassy-carbon electrode in evidence. When the base solution pH was 4.68, and the accumulation time was 300 s, the positions of the stripping peaks were optimal, and the peak signals were at a maximum. When the concentration of the film coating solution was 0.03 mol/l HgCl2 and the mercury coating step was repeated three times, the prepared electrode showed a moderately high elution peak with little noise. The optimized electrode demonstrated superior precision and detection limits in the simultaneous detection of Zn2+, Cd2+, Pb2+, and Cu2+, compared with the uncoated electrode. The calibration curves were highly linear with determination coefficients (R-2 ) of 0.9913 (Cu2+), 0.9939 (Pb2+), 0.9933 (Cd2+), and 0.9962 (Zn2+); the detection limits (mu g/l) were 5 for Cu2+, 1 for Pb2+, 0.1 for Cd2+, and 10 for Zn2+, and the relative standard deviations obtained from five replicate experiments were 4.1% (Cu2+), 2.1% (Pb2+), 2.7% (Cd2+), and 3.4% (Zn2+). It is reasonable to suppose that the precision and detection limits of this mercury film electrode may meet the requirements for the simultaneous detection of multiple heavy metal ions in water in the natural environment.
引用
收藏
页码:203 / 216
页数:14
相关论文
共 50 条
  • [1] Optimization of Zn2+, Cd2+, Pb2+ and Cu2+ determination in the coastal water by using voltammetry
    Mohamed, Khairul Nizam
    Ramjam, Nur Jannati
    Qing, Ng Li
    Junairi, Aleef Syamim
    Ruzahan, Nur Izzati
    Razak, Abdul Rahman Hashimi Abdul
    Ghani, Mohamad Azrul
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (03):
  • [2] SIMULTANEOUS DETERMINATION OF THE ZN2+, CD2+, PB2+ AND CU2+ TRACES BY ANODIC-STRIPPING VOLTAMETRIC
    VARTIRES, I
    BORDA, M
    BONCIOCAT, N
    TOTIR, N
    REVISTA DE CHIMIE, 1979, 30 (08): : 791 - 798
  • [3] Immobilization of Cu2+, Zn2+, Pb2+, and Cd2+ during geopolymerization
    Lei Zheng
    Wei Wang
    Wei Qiao
    Yunchun Shi
    Xiao Liu
    Frontiers of Environmental Science & Engineering, 2015, 9 : 642 - 648
  • [4] Immobilization of Cu2+, Zn2+, Pb2+, and Cd2+ during geopolymerization
    Zheng, Lei
    Wang, Wei
    Qiao, Wei
    Shi, Yunchun
    Liu, Xiao
    FRONTIERS OF ENVIRONMENTAL SCIENCE & ENGINEERING, 2015, 9 (04) : 642 - 648
  • [5] Effects of Pb2+, Cd2+ and Cu2+ on the Aqueous Zn2+ Sorption by Hydroxyapatite
    QI Yong and LIU Yu School of Material Science and Technology
    Acta Geologica Sinica(English Edition), 2006, (02) : 226 - 229
  • [6] Effects of Pb2+, Cd2+ and Cu2+ on the aqueous Zn2+ sorption by hydroxyapatite
    Qi, Yong
    Liu, Yu
    ACTA GEOLOGICA SINICA-ENGLISH EDITION, 2006, 80 (02) : 226 - 229
  • [7] Remove of heavy metals(Cu2+, Pb2+, Zn2+ and Cd2+) in water through modified diatomite
    Jia Liu
    Hong-liang Wang
    Chun-xin Lü
    Han-fei Liu
    Zhi-xin Guo
    Chun-li Kang
    Chemical Research in Chinese Universities, 2013, 29 : 445 - 448
  • [8] Remove of Heavy Metals(Cu2+, Pb2+, Zn2+ and Cd2+) in Water Through Modified Diatomite
    Liu Jia
    Wang Hong-liang
    Lu Chun-xin
    Liu Han-fei
    Guo Zhi-xin
    Kang Chun-li
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2013, 29 (03) : 445 - 448
  • [9] Simultaneous determination of Cu2+, Zn2+, Cd2+, Hg2+ and Pb2+ by using second-derivative spectrophotometry method
    Han, Yanyan
    Li, Yan
    Si, Wei
    Wei, Dong
    Yao, Zhenxing
    Zheng, Xianpeng
    Du, Bin
    Wei, Qin
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2011, 79 (05) : 1546 - 1551
  • [10] Simultaneous Determination of Pb2+ and Cd2+ in Isatis Root by a Bismuth/ Graphene Composite Film Modified Glassy Carbon Electrode
    Wu Min
    Li Hui
    Wang Xue
    Wang Qing-Jiang
    He Pin-Gang
    Fang Yu-Zhi
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (04) : 525 - 529