The "pull-push" technique to deal with a redundant Eustachian valve interfering with placement of a PFO occluder

被引:10
作者
Butera, Gianfranco
Montinaro, Antonio
Carminati, Mario
机构
[1] Ist Policlin San Donato, San Donato Milanese, MI, Italy
[2] Osped Vito Fazzi, Dept Invas Cardiol, Lecce, Italy
关键词
cardiac catheterization; heart; patent foramen ovale;
D O I
10.1002/ccd.20903
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To evaluate the role of a new technique to deal with a redundant Eustachian valve (EV) interfering with placement of a patent foramen ovale (PFO) occluder. Background: The EV is a remnant of the embryonic valve of the sinus venosus. In rare occasions, it is large and redundant and it may interfere with catheters and devices used in cardiac catheterization. Methods: We have developed a new technique to control the EV in order to avoid interferences with the device for closure of atrial septal defects and PFO's. This technique is called "pull-push" technique and consists in pulling down on the inferior vena cava the redundant EV by using a 6 Fr pigtail catheter while a second operator pushes the right atrial disc out of the long sheath. Results: Here, we report on two patients with a patent foramen ovale, in whom the EV prevented the right atrial disc of an Amplatzer PFO occluder to be completely flat against the interatrial septum. Finally, we used this technique in one more patient to avoid any interference of a very redundant EV during placement of a Starflex device. Conclusions: In conclusion. the so called "pull-push" technique is an alternative and easy technique to control the EV in order to avoid interferences with the device for closure of atrial septal defects and PFO's (C) 2006 Wiley-Liss, Inc.
引用
收藏
页码:961 / 964
页数:4
相关论文
共 7 条
[1]   Transcatheter closure as standard treatment for most interatrial defects:: experience in 200 patients treated with the Amplatzer™ Septal Occluder [J].
Berger, F ;
Ewert, P ;
Björnstad, PG ;
Dähnert, I ;
Krings, G ;
Brilla-Austgenat, I ;
Vogel, M ;
Lange, PE .
CARDIOLOGY IN THE YOUNG, 1999, 9 (05) :468-473
[2]   Chiari network entanglement and herniation into the left atrium by an atrial septal defect occluder device [J].
Cooke, JC ;
Gelman, JS ;
Harper, RW .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (07) :601-603
[3]  
McMahon CJ, 2000, CATHETER CARDIO INTE, V51, P455, DOI 10.1002/1522-726X(200012)51:4<455::AID-CCD17>3.0.CO
[4]  
2-E
[5]   Persistent redundant Eustachian valve interfering with amplatzer PFO occluder placement: Anatomico-clinical and technical implications [J].
Onorato, E ;
Pera, IG ;
Melzi, G ;
Rigatelli, G .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 55 (04) :521-524
[6]  
Salmeron O, 1966, Arch Inst Cardiol Mex, V36, P387
[7]   Entrapment of an ablation catheter in the cardiac venous system: A case report [J].
Sopher, SM ;
Grace, AA ;
Heald, SC ;
Rowland, E .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (06) :1306-1308