Does the apodized diffractive intraocular lens Acrysof ReSTOR Natural™ interfere with FDT Matrix perimetry results?

被引:6
作者
Bojikian, Karine Duarte [1 ]
Vita, Joao Brasil [1 ]
Dal Forno, Catia Potira [1 ]
Tranjan Neto, Alfredo [1 ]
de Moura, Christiane Rolim [1 ]
机构
[1] Univ Fed Sao Paulo, Dept Oftalmol, Sao Paulo, Brazil
关键词
Cataract; Lenses; intraocular; Perimetry; Glaucoma; Lens implantation; Contrast sensibility; Phacoemulsification; DOUBLING-TECHNOLOGY PERIMETRY; CONTRAST SENSITIVITY; HUMPHREY-MATRIX; CATARACT; GLAUCOMA; FOCUS; CLEAR; IOL;
D O I
10.1590/S0004-27492009000600003
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the effect of an apodized diffractive intraocular lens (IOL) (Acrysof ReSTOR Natural (TM)) and its yellow counterpart (Natural IQ (TM)) on frequency doubling technology (FDT) perimetry results. Methods: This study included 37 eyes from 22 patients at the "Centro Oftalmologico Tranjan" who had undergone uncomplicated phacoemulsification and intraocular lens implantation (17 Acrysof ReSTOR Natural (TM), 20 Natural IQ (TM)) performed by the same surgeon, at least three months prior to the study. Patients were subject to frequency doubling technology Matrix Perimeter testing. Results: The patients were between 41 to 79 years old (mean, 70.78 +/- 9.83) in the Natural IQ (TM) and 49 to 81 years old (mean, 67.11 +/- 11.48) in the Acrysof ReSTOR Natural (TM) group, and the mean IOP was 13.64 +/- 2.02 mmHg in the Natural IQ (TM) 12.94 +/- 1.39 mmHg in the Acrysof ReSTOR Natural (TM) group. The mean pupillary diameter under scotopic conditions was 6.63 +/- 1.16 mm in the Natural IQ (TM) group and 7.20 +/- 1.8 mm in the Acrysof ReSTOR Natural (TM) group (p = 0.20). The mean deviation was -1.83 +/- 3.46 dB in the Natural IQ (TM) group and -1.77 +/- 3.94 dB in the Acrysof ReSTOR Natural (TM) group (p = 0.28). The pattern standard deviation was 3.49 +/- 0.79 dB in the Natural IQ (TM) group and 3.20 +/- 0.86 dB in the Acrysof ReSTOR Natural (TM) group (p = 0.27). Conclusion: There was no difference in the results of FDT Matrix perimetry in eyes that received apodized diffractive IOLs implant or eyes that received monofocal intraocular lens implant.
引用
收藏
页码:755 / 759
页数:5
相关论文
共 26 条
[1]   Frequency doubling technology perimetry for the detection of glaucomatous visual field loss [J].
Alward, WLM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (03) :376-378
[2]   Frequency Doubling technology staging system 2 [J].
Brusini, Paolo .
JOURNAL OF GLAUCOMA, 2006, 15 (04) :315-320
[3]   Visual field testing with the new Humphrey Matrix: a comparison between the FDT N-30 and Matrix N-30-F tests [J].
Brusini, Paolo ;
Salvetat, Maria Letizia ;
Zeppieri, Marco ;
Tosoni, Claudia ;
Parisi, Lucia ;
Felletti, Mirella .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2006, 84 (03) :351-356
[4]   Learning effect of Humphrey Matrix Frequency Doubling Technology perimetry in patients with ocular hypertension [J].
Centofanti, Marco ;
Fogagnolo, Paolo ;
Oddone, Francesco ;
Orzalesi, Nicola ;
Vetrugno, Michele ;
Manni, Gianluca ;
Rossetti, Luca .
JOURNAL OF GLAUCOMA, 2008, 17 (06) :436-441
[5]   Early glaucoma detection using the Humphrey Matrix perimeter, GDx VCC, stratus OCT, and retinal nerve fiber layer photography [J].
Hong, Samin ;
Ahn, Hyunseok ;
Ha, Seung Joo ;
Yeom, Ho Yeop ;
Seong, Gong Je ;
Hong, Young Jae .
OPHTHALMOLOGY, 2007, 114 (02) :210-215
[6]   Effect of the AcrySof Natural intraocular lens on blue-yellow perimetry [J].
Kara-Junior, Newton ;
Jardim, Juliana Lopes ;
Leme, Eliana de Oliveira ;
Dall'Col, Marcelo ;
Susanna Junior, Remo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (08) :1328-1330
[7]  
KATZ J, 1988, OPHTHALMIC SURG LAS, V19, P585
[8]   FREQUENCY DOUBLING IN VISUAL RESPONSES [J].
KELLY, DH .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1966, 56 (11) :1628-&
[9]   European multicenter study of the AcrySof ReSTOR apodized diffractive intraocular lens [J].
Kohnen, T ;
Allen, D ;
Boureau, C ;
Dublineau, P ;
Hartmann, C ;
Mehdorn, E ;
Rozot, P ;
Tassinari, G .
OPHTHALMOLOGY, 2006, 113 (04) :578-584
[10]   Effect of cataract extraction on frequency doubling technology perimetry [J].
Kook, MS ;
Yang, SJ ;
Kim, S ;
Chung, J ;
Kim, ST ;
Tchah, H .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 138 (01) :85-90