Effect of SSI on Vibration Control of Structures with Tuned Vibration Absorbers

被引:31
作者
Elias, Said [1 ,2 ]
机构
[1] Univ Iceland, Earthquake Engn Res Ctr, IS-101 Reykjavik, Iceland
[2] Herat Univ, Dept Civil Engn, Herat, Afghanistan
关键词
MASS DAMPERS; WIND RESPONSE; PARAMETERS; BUILDINGS;
D O I
10.1155/2019/7463031
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
is paper investigates the effect of considering soil-structure interaction (SSI) in seismic responses of reinforced concrete (RC) chimneys installed by distributed tuned vibration absorbers vertically (d-MTVAs). A multimode control approach is used to design the d-MTVAs. Two-dimensional (2D) RC chimney is the assembly of beam elements. Frequency-independent constants for the springs and dashpots are used for modeling the raft and the surrounding soil. (e equations of motion for nonclassically damped systems are derived and solved using Newmark's method. (e effectiveness of the d-MTVAs is weighed against the case of single tuned vibration absorber (STVA), d-MTVAs suppressing the first modal responses (d-MTVAs-1), and randomly distributed MTVAs (ad-MTVAs). Additionally, parametric studies are conducted for varying mass and damping ratios in the STVA, d-MTVAs-1, adMTVAs, and d-MTVAs. In order to show the efficiency in the STVA, d-MTVAs-1, ad-MTVAs, and d-MTVAs cases, responses (displacement and acceleration) at top of the RC chimney while subjected to different real earthquake excitations are computed. It is concluded that the STVA, d-MTVAs-1, ad-MTVAs, and d-MTVAs are effective in response mitigation of the RC chimney; however, d-MTVAs are more efficient while considering equal total mass of the TVA(s). Moreover, the soil type significantly influenced the design parameters of the STVA/d-MTVAs-1/ad-MTVAs/d-MTVAs and seismic response of the RC chimney.
引用
收藏
页数:12
相关论文
共 27 条
[1]  
Aly A. M., 2012, STRUCT DESIGN TALL S, V23, P664
[2]   Vibration control of high-rise buildings for wind: a robust passive and active tuned mass damper [J].
Aly, Aly Mousaad .
SMART STRUCTURES AND SYSTEMS, 2014, 13 (03) :473-500
[3]  
[Anonymous], 2011, SMART MAT RES
[4]   Across-wind aerodynamic parameters of tall chimneys with circular cross section - a new empirical model [J].
Arunachalam, S ;
Govindaraju, SP ;
Lakshmanan, N ;
Rao, TVSRA .
ENGINEERING STRUCTURES, 2001, 23 (05) :502-520
[5]  
Bandivadekar T., 2012, J VIB CONTROL, V19, P1854
[6]   FAULT TOLERANT CONTROL WITH DISTURBANCE REJECTION AND ATTENUATION PERFORMANCE FOR SYSTEMS WITH MULTIPLE DISTURBANCES [J].
Cao, Songyin ;
Guo, Lei ;
Wen, Xinyu .
ASIAN JOURNAL OF CONTROL, 2011, 13 (06) :1056-1064
[7]   Theoretical and experimental free vibrations of tall industrial chimney with flexibility of soil [J].
Chmielewski, T ;
Górski, P ;
Beirow, B ;
Kretzschmar, J .
ENGINEERING STRUCTURES, 2005, 27 (01) :25-34
[8]   AN ANALYTICAL STUDY OF THE ACROSS-WIND RESPONSE OF CYLINDERS DUE TO VORTEX SHEDDING [J].
DATTA, TK ;
JAIN, AK .
ENGINEERING STRUCTURES, 1987, 9 (01) :27-31
[9]  
Elias S., 2018, SHOCK VIB, P1
[10]  
Elias S., 2017, J EARTHQUAKE ENG