Comparison between PRIMO and EGSnrc Monte Carlo models of the Varian True Beam linear accelerator

被引:8
作者
Aamri, Hussin [1 ,2 ]
Fielding, Andrew [2 ]
Aamry, Ali [3 ]
Sulieman, Abdelmoneim [4 ]
Tamam, Nissren [5 ]
Alkhorayef, Mohammed [6 ,7 ]
Bradley, David A. [7 ,8 ]
机构
[1] King Saud Univ Med City KSUMC, Med Phys Dept, Riyadh, Saudi Arabia
[2] Queensland Univ Technol, Sci & Engn Fac, Brisbane, Qld, Australia
[3] King Saud Med City, Nucl Med Dept, Riyadh, Saudi Arabia
[4] Prince Sattam Bin Abdulaziz Univ, Coll Appl Med Sci, Radiol & Med Imaging, Alkharj, Saudi Arabia
[5] Princess Nourah Bint Abdulrahman Univ, Coll Sci, Phys Dept, POB 84428, Riyadh 11671, Saudi Arabia
[6] King Saud Univ, Coll Appl Med Sci, Dept Radiol Sci, POB 10219, Riyadh 11433, Saudi Arabia
[7] Univ Surrey, Dept Phys, Ctr Nucl & Radiat Phys, Guildford GU2 7XH, Surrey, England
[8] Sunway Univ, Ctr Biomed Phys, Jalan Univ, Pj 46150, Malaysia
关键词
Monte Carlo simulation; Flattening-filter free (FFF); Linear accelerator (LINAC); EGSnrc; Dose in build-up region; PRIMO Code; SIMULATION; PHOTON; PENELOPE; LINAC;
D O I
10.1016/j.radphyschem.2020.109013
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The study objectives were to simulate a 6 MV flattening filter-free (FFF) photon beam of a TrueBeam Varian LINAC, using the PRIMO code. The depth-dose profiles for various jaw open fields and cross-beam profiles for various depths inside water phantoms were determined using PRIMO simulations and were compared with the EGSnrc simulation results. A 93% match between both codes has generally been obtained, with a systematic variation in agreement between the two models that increases with field size. The closest agreement, to within 94%, was obtained for a 6 x 6 cm(2) jaw open field at 5.0 cm and 10.0 cm depths, better at 10- than at 5.0 cm depth. The effects of how scatter is modelled has been shown to result in the differences.
引用
收藏
页数:9
相关论文
共 21 条
[1]  
Abuahmadeh O., 2014, SCI ENG FACULTY, P1
[2]   INFLUENCE OF ENERGY AND ANGULAR SPREAD ON STOPPING-POWER RATIOS FOR ELECTRON-BEAMS [J].
ANDREO, P ;
BRAHME, A ;
NAHUM, A ;
MATTSSON, O .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (06) :751-768
[3]  
[Anonymous], 2011, JACMP
[4]   Monte Carlo simulation of TrueBeam flattening-filter-free beams using Varian phase-space files: Comparison with experimental data [J].
Belosi, Maria F. ;
Rodriguez, Miguel ;
Fogliata, Antonella ;
Cozzi, Luca ;
Sempau, Josep ;
Clivio, Alessandro ;
Nicolini, Giorgia ;
Vanetti, Eugenio ;
Krauss, Harald ;
Khamphan, Catherine ;
Fenoglietto, Pascal ;
Puxeu, Josep ;
Fedele, David ;
Mancosu, Pietro ;
Brualla, Lorenzo .
MEDICAL PHYSICS, 2014, 41 (05)
[5]  
Capote R., 2006, INDCNDS0484
[6]   Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning [J].
Chetty, Indrin J. ;
Curran, Bruce ;
Cygler, Joanna E. ;
DeMarco, John J. ;
Ezzell, Gary ;
Faddegon, Bruce A. ;
Kawrakow, Iwan ;
Keall, Paul J. ;
Liu, Helen ;
Ma, C. -M. Charlie ;
Rogers, D. W. O. ;
Seuntjens, Jan ;
Sheikh-Bagheri, Daryoush ;
Siebers, Jeffrey V. .
MEDICAL PHYSICS, 2007, 34 (12) :4818-4853
[7]   Monte Carlo calculated correction factors for diodes and ion chambers in small photon fields [J].
Czarnecki, D. ;
Zink, K. .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (08) :2431-2444
[8]   Assessment of cone beam CT registration for prostate radiation therapy: Fiducial marker and soft tissue methods [J].
Deegan, Timothy ;
Owen, Rebecca ;
Holt, Tanya ;
Fielding, Andrew ;
Biggs, Jennifer ;
Parfitt, Matthew ;
Coates, Alicia ;
Roberts, Lisa .
JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2015, 59 (01) :91-98
[9]   Monte Carlo Simulation of 6 MV Flattening Filter Free Photon Beam of TrueBeam STx LINAC at Songklanagarind Hospital [J].
Efendi, M. Arif ;
Funsian, Amporn ;
Chittrakarn, Thawat ;
Bhongsuwan, Tripob .
SAINS MALAYSIANA, 2017, 46 (09) :1407-1411
[10]   Determination and verification of the x-ray spectrum of a CT scanner [J].
Hassan, Ahmad Ibrahim ;
Skalej, Martin ;
Schlattl, Helmut ;
Hoeschen, Christoph .
JOURNAL OF MEDICAL IMAGING, 2018, 5 (01)