Microcrystallography using single-bounce monocapillary optics

被引:12
作者
Gillilan, R. E. [1 ]
Cook, M. J. [1 ]
Cornaby, S. W. [2 ,3 ]
Bilderback, D. H. [1 ,2 ]
机构
[1] MacCHESS Macromol Diffract Facil CHESS, Ithaca, NY USA
[2] Cornell Univ, Sch Appl & Engn Phys, Ithaca, NY 14853 USA
[3] Cornell Univ, CHESS, Ithaca, NY USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
microbeam single-bounce capillary optics; GLASS-CAPILLARY OPTICS; ZINC TRANSPORTER CZRB; X-RAY REFLECTION; FILM WAVE-GUIDE; SYNCHROTRON-RADIATION; PROTEIN CRYSTALLOGRAPHY; DIFFRACTION DATA; THERMUS-THERMOPHILUS; DATA-COLLECTION; BEAM;
D O I
10.1107/S0909049509053564
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
X-ray microbeams have become increasingly valuable in protein crystallography. A number of synchrotron beamlines worldwide have adapted to handling smaller and more challenging samples by providing a combination of high-precision sample-positioning hardware, special visible-light optics for sample visualization, and small-diameter X-ray beams with low background scatter. Most commonly, X-ray microbeams with diameters ranging from 50 mm to 1 mm are produced by Kirkpatrick and Baez mirrors in combination with defining apertures and scatter guards. A simple alternative based on single-bounce glass monocapillary X-ray optics is presented. The basic capillary design considerations are discussed and a practical and robust implementation that capitalizes on existing beamline hardware is presented. A design for mounting the capillary is presented which eliminates parasitic scattering and reduces deformations of the optic to a degree suitable for use on next-generation X-ray sources. Comparison of diffraction data statistics for microcrystals using microbeam and conventional aperture-collimated beam shows that capillary-focused beam can deliver significant improvement. Statistics also confirm that the annular beam profile produced by the capillary optic does not impact data quality in an observable way. Examples are given of new structures recently solved using this technology. Single-bounce monocapillary optics can offer an attractive alternative for retrofitting existing beamlines for microcrystallography.
引用
收藏
页码:227 / 236
页数:10
相关论文
共 55 条
[1]  
[Anonymous], AIP C P
[2]   X-ray refractive planar lens with minimized absorption [J].
Aristov, V ;
Grigoriev, M ;
Kuznetsov, S ;
Shabelnikov, L ;
Yunkin, V ;
Weitkamp, T ;
Rau, C ;
Snigireva, I ;
Snigirev, A ;
Hoffmann, M ;
Voges, E .
APPLIED PHYSICS LETTERS, 2000, 77 (24) :4058-4060
[3]   FOCUSING OF X-RAYS BY TOTAL EXTERNAL REFLECTION FROM A PARABOLOIDALLY TAPERED GLASS-CAPILLARY [J].
BALAIC, DX ;
NUGENT, KA ;
BARNEA, Z ;
GARRETT, R ;
WILKINS, SW .
JOURNAL OF SYNCHROTRON RADIATION, 1995, 2 :296-299
[4]   High-flux hard X-ray microbeam using a single-bounce capillary with doubly focused undulator beam [J].
Barrea, Raul A. ;
Huang, Rong ;
Cornaby, Sterling ;
Bilderback, Donald H. ;
Irving, Thomas C. .
JOURNAL OF SYNCHROTRON RADIATION, 2009, 16 :76-82
[5]   X-RAY APPLICATIONS WITH GLASS-CAPILLARY OPTICS [J].
BILDERBACK, DH ;
THIEL, DJ ;
PAHL, R ;
BRISTER, KE .
JOURNAL OF SYNCHROTRON RADIATION, 1994, 1 :37-42
[6]   Measurement errors and their consequences in protein crystallography [J].
Borek, D ;
Minor, W ;
Otwinowski, Z .
ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 2003, 59 :2031-2038
[7]   RAY-TRACING OF X-RAY FOCUSING CAPILLARIES [J].
CHEN, GJ ;
CERRINA, F ;
VOSS, KF ;
KIM, KH ;
BROWN, FC .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 347 (1-3) :407-411
[8]   Insights into the mode of action of a putative zinc transporter CzrB in Thermus thermophilus [J].
Cherezov, Vadim ;
Hofer, Nicole ;
Szebenyi, Doletha M. E. ;
Kolaj, Olga ;
Wall, J. Gerard ;
Gillilan, Richard ;
Srinivasan, Vasundara ;
Jaroniec, Christopher P. ;
Caffrey, Martin .
STRUCTURE, 2008, 16 (09) :1378-1388
[9]  
CORNABY S, 2008, ADV XRAY ANAL, V52
[10]  
CORNABY SW, 2008, THESIS CORNELL U US