Measuring airway dimensions during bronchoscopy using anatomical optical coherence tomography

被引:55
作者
Williamson, J. P. [1 ,3 ]
Armstrong, J. J. [4 ]
McLaughlin, R. A. [4 ]
Noble, P. B. [6 ]
West, A. R. [5 ]
Becker, S. [4 ]
Curatolo, A. [4 ]
Noffsinger, W. J. [1 ]
Mitchell, H. W. [5 ]
Phillips, M. J. [2 ]
Sampson, D. D. [4 ]
Hillman, D. R. [1 ,7 ]
Eastwood, P. R. [1 ,3 ,7 ]
机构
[1] Sir Charles Gairdner Hosp, Dept Pulm Physiol, Perth, WA 6000, Australia
[2] Sir Charles Gairdner Hosp, Dept Resp Med, Perth, WA 6000, Australia
[3] Univ Western Australia, Sch Anat & Human Biol, Nedlands, WA 6009, Australia
[4] Univ Western Australia, Opt Biomed Engn Lab, Sch Elect Elect & Comp Engn, Nedlands, WA 6009, Australia
[5] Univ Western Australia, Sch Biomed Biomol & Chem Sci, Nedlands, WA 6009, Australia
[6] Telethon Inst Child Hlth Res, Div Clin Sci, Perth, WA, Australia
[7] W Australian Sleep Disorders Res Inst, Perth, WA, Australia
基金
英国医学研究理事会;
关键词
Airway dimensions; computed tomography; interventional bronchoscopy; optical coherence tomography; quantitative bronchoscopy; COMPUTED-TOMOGRAPHY; PHARYNGEAL SHAPE; SIZE; INDIVIDUALS; CALIBER; LUMEN; LUNG;
D O I
10.1183/09031936.00041809
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Airway dimensions are difficult to quantify bronchoscopically because of optical distortion and a limited ability to gauge depth. Anatomical optical coherence tomography (aOCT), a novel imaging technique, may overcome these limitations. This study evaluated the accuracy of aOCT against existing techniques in phantom, excised pig and in vivo human airways. Three comparative studies were performed: 1) micrometer-derived area measurements in 10 plastic tubes were compared with aOCT-derived area; 2) aOCT-derived airway compliance curves from excised pig airways were compared with curves derived using an endoscopic technique; and 3) airway dimensions from the trachea to subsegmental bronchi were measured using aOCT in four anaesthetised patients during bronchoscopy and compared with computed tomography (CT) measurements. Measurements in plastic tubes revealed aOCT to be accurate and reliable. In pig airways, aOCT-derived compliance measurements compared closely with endoscopic data. In human airways, dimensions measured with aOCT and CT correlated closely. Bland-Altman plots showed that aOCT diameter and area measurements were higher than CT measurements by 7.6% and 15.1%, respectively. Airway measurements using aOCT are accurate, reliable and compare favourably with existing imaging techniques. Using aOCT with conventional bronchoscopy allows real-time measurement of airway dimensions and could be useful clinically in settings where knowledge of airway calibre is required.
引用
收藏
页码:34 / 41
页数:8
相关论文
共 50 条
  • [41] Microscopic Small Airway Abnormalities Identified in Early Idiopathic Pulmonary Fibrosis In Vivo Using Endobronchial Optical Coherence Tomography
    Berigei, Sarita R.
    Nandy, Sreyankar
    Yamamoto, Satomi
    Raphaely, Rebecca A.
    DeCoursey, Amalia
    Lee, Jaeyul
    Sharma, Amita
    Auchincloss, Hugh G.
    Gaissert, Henning
    Lanuti, Michael
    Ott, Harald C.
    Sachdeva, Uma M.
    Wright, Cameron D.
    Zhao, Sophia H.
    Hallowell, Robert W.
    Shea, Barry S.
    Muniappan, Ashok
    Keyes, Colleen M.
    Hariri, Lida P.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 210 (04) : 473 - 483
  • [42] Extracting Features from Optical Coherence Tomography for Measuring Optical Nerve Thickness
    Lay-Ekuakille, A.
    Trabacca, A.
    De Santis, R.
    Ciccarelli, M.
    Mvemba, P. Kapita
    Morello, R.
    2018 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2018, : 880 - 884
  • [43] Optical Vaginal Biopsy Using Optical Coherence Tomography
    Sudol, Neha Talreja
    Miao, Yusi
    Li, Yan
    Chen, Jason J.
    Jing, Joseph C.
    Zhu, Jiang
    Tadir, Yona
    Chen, Zhongping
    Lane, Felicia
    FEMALE PELVIC MEDICINE AND RECONSTRUCTIVE SURGERY, 2020, 26 (02): : 155 - 158
  • [44] Non-Destructive Analysis of the Internal Anatomical Structures of Mosquito Specimens Using Optical Coherence Tomography
    Ravichandran, Naresh Kumar
    Wijesinghe, Ruchire Eranga
    Lee, Seung-Yeol
    Choi, Kwang Shik
    Jeon, Mansik
    Jung, Hee-Young
    Kim, Jeehyun
    SENSORS, 2017, 17 (08):
  • [45] Intraoperative long range optical coherence tomography as a novel method of imaging the pediatric upper airway before and after adenotonsillectomy
    Lazarow, Frances B.
    Ahuja, Gurpreet S.
    Loy, Anthony Chin
    Su, Erica
    Nguyen, Tony D.
    Sharma, Giriraj K.
    Wang, Alex
    Jing, Joseph
    Chen, Zhongping
    Wong, Brian J. F.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2015, 79 (01) : 63 - 70
  • [46] Using optical coherence tomography and optical coherence tomography angiography to delineate neurovascular homeostasis in migraine: a review
    Chaliha, Devahuti R.
    Vaccarezza, Mauro
    Charng, Jason
    Chen, Fred K.
    Lim, Amy
    Drummond, Peter
    Takechi, Ryusuke
    Lam, Virginie
    Dhaliwal, Satvinder S.
    Mamo, John C. L.
    FRONTIERS IN NEUROSCIENCE, 2024, 18
  • [47] Airway morphological abnormalities of bronchiolitis assessed by endobronchial optical coherence tomography
    Su, Zhu-Quan
    Zhong, Ming-Lu
    Fan, Ming-Yue
    Rao, Wan-Yuan
    Zhou, Zi-Qing
    Chen, Yu
    Chen, Xiao-Bo
    Tang, Chun-Li
    Zhong, Chang-Hao
    Li, Shi-Yue
    THERAPEUTIC ADVANCES IN RESPIRATORY DISEASE, 2023, 17
  • [48] Optical coherence elastography: Strain imaging in tissue using optical coherence tomography
    Kennedy, Brendan F.
    Kennedy, Kelsey M.
    Ford, Chris
    McLaughlin, Robert A.
    Bush, Mark B.
    Sampson, David D.
    22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3, 2012, 8421
  • [49] Optical coherence tomography for identification and quantification of human airway wall layers
    d'Hooghe, Julia N. S.
    Goorsenberg, Annika W. M.
    de Bruin, Daniel M.
    Roelofs, Joris J. T. H.
    Annema, Jouke T.
    Bonta, Peter I.
    PLOS ONE, 2017, 12 (10):
  • [50] A rapid method of measuring dispersion in low coherence interferometry and optical coherence tomography systems
    Meadway, Alexander
    Darbrazi, Seyed Hamid Hosseiny
    Dobre, George
    Rosen, Richard B.
    Podoleanu, Adrian Gh
    JOURNAL OF OPTICS, 2010, 12 (01)