Measuring airway dimensions during bronchoscopy using anatomical optical coherence tomography

被引:55
作者
Williamson, J. P. [1 ,3 ]
Armstrong, J. J. [4 ]
McLaughlin, R. A. [4 ]
Noble, P. B. [6 ]
West, A. R. [5 ]
Becker, S. [4 ]
Curatolo, A. [4 ]
Noffsinger, W. J. [1 ]
Mitchell, H. W. [5 ]
Phillips, M. J. [2 ]
Sampson, D. D. [4 ]
Hillman, D. R. [1 ,7 ]
Eastwood, P. R. [1 ,3 ,7 ]
机构
[1] Sir Charles Gairdner Hosp, Dept Pulm Physiol, Perth, WA 6000, Australia
[2] Sir Charles Gairdner Hosp, Dept Resp Med, Perth, WA 6000, Australia
[3] Univ Western Australia, Sch Anat & Human Biol, Nedlands, WA 6009, Australia
[4] Univ Western Australia, Opt Biomed Engn Lab, Sch Elect Elect & Comp Engn, Nedlands, WA 6009, Australia
[5] Univ Western Australia, Sch Biomed Biomol & Chem Sci, Nedlands, WA 6009, Australia
[6] Telethon Inst Child Hlth Res, Div Clin Sci, Perth, WA, Australia
[7] W Australian Sleep Disorders Res Inst, Perth, WA, Australia
基金
英国医学研究理事会;
关键词
Airway dimensions; computed tomography; interventional bronchoscopy; optical coherence tomography; quantitative bronchoscopy; COMPUTED-TOMOGRAPHY; PHARYNGEAL SHAPE; SIZE; INDIVIDUALS; CALIBER; LUMEN; LUNG;
D O I
10.1183/09031936.00041809
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Airway dimensions are difficult to quantify bronchoscopically because of optical distortion and a limited ability to gauge depth. Anatomical optical coherence tomography (aOCT), a novel imaging technique, may overcome these limitations. This study evaluated the accuracy of aOCT against existing techniques in phantom, excised pig and in vivo human airways. Three comparative studies were performed: 1) micrometer-derived area measurements in 10 plastic tubes were compared with aOCT-derived area; 2) aOCT-derived airway compliance curves from excised pig airways were compared with curves derived using an endoscopic technique; and 3) airway dimensions from the trachea to subsegmental bronchi were measured using aOCT in four anaesthetised patients during bronchoscopy and compared with computed tomography (CT) measurements. Measurements in plastic tubes revealed aOCT to be accurate and reliable. In pig airways, aOCT-derived compliance measurements compared closely with endoscopic data. In human airways, dimensions measured with aOCT and CT correlated closely. Bland-Altman plots showed that aOCT diameter and area measurements were higher than CT measurements by 7.6% and 15.1%, respectively. Airway measurements using aOCT are accurate, reliable and compare favourably with existing imaging techniques. Using aOCT with conventional bronchoscopy allows real-time measurement of airway dimensions and could be useful clinically in settings where knowledge of airway calibre is required.
引用
收藏
页码:34 / 41
页数:8
相关论文
共 50 条
  • [31] Anatomical optical coherence tomography - a safe and effective tool for quantitative long-term monitoring of airway size and shape
    Amstrong, J. J.
    Becker, S.
    McLaughlin, R. A.
    Leigh, M. S.
    Williamson, J.
    Walsh, J. H.
    Hillman, D. R.
    Eastwood, P. R.
    Sampson, D. D.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS IV, 2008, 6842
  • [32] Quantitative upper airway imaging with anatomic optical coherence tomography
    Armstrong, JJ
    Leigh, MS
    Sampson, DD
    Walsh, JH
    Hillman, DR
    Eastwood, PR
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2006, 173 (02) : 226 - 233
  • [33] The influence of reconstruction algorithm on the measurement of airway dimensions using computed tomography
    Wong, Jonathan C.
    Nakano, Yasutaka
    Coxson, Harvey O.
    Mueller, Nestor L.
    Pare, Peter D.
    Hogg, James C.
    MEDICAL IMAGING 2008: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES, 2008, 6916
  • [34] Significances of spirometry and impulse oscillometry for detecting small airway disorders assessed with endobronchial optical coherence tomography in COPD
    Su, Zhu-Quan
    Guan, Wei-Jie
    Li, Shi-Yue
    Ding, Ming
    Chen, Yu
    Jiang, Mei
    Chen, Xiao-Bo
    Zhong, Chang-Hao
    Tang, Chun-Li
    Zhong, Nan-Shan
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2018, 13 : 3031 - 3044
  • [35] Measuring the vibrational response of the mouse ear using coherently interleaved optical coherence tomography
    Shelton, Ryan
    Gao, Simon
    Oghalai, John S.
    Applegate, Brian E.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVI, 2012, 8213
  • [36] Measuring the thickness of the peritoneal membrane in mice with optical coherence tomography
    Alwafi, Reem
    Dickinson, Mark
    Brenchley, Paul
    Walkin, Louise
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES V, 2011, 8091
  • [37] Automatic proximal airway volume segmentation using optical coherence tomography for assessment of inhalation injury
    Miao, Yusi
    Choi, Jae Hyek
    Chou, Li-Dek
    Desai, Vineet
    Roberts, Teryn R.
    Beely, Brendan M.
    Wendorff, Daniel S.
    Espinoza, Mark
    Sieck, Kyle
    Cancio, Leopoldo C.
    Brenner, Matthew
    Batchinsky, Andriy I.
    Chen, Zhongping
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2019, 87 : S132 - S137
  • [38] Doppler optical coherence tomography for measuring flow in engineered tissue
    Mason, C
    Markusen, JF
    Town, MA
    Dunnill, P
    Wang, RK
    BIOSENSORS & BIOELECTRONICS, 2004, 20 (03) : 414 - 423
  • [39] Ventricular Fibrillation during Optical Coherence Tomography
    Martin, Paula Vela
    Serrano, Carlos Arellano
    Ros, Alvaro Lorente
    Oteo, Juan Francisco
    Garcia-Touchard, Arturo
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2024, 11 (07)
  • [40] Comparison of coronary arterial lumen dimensions on angiography and plaque characteristics on optical coherence tomography images and their changes induced by statin
    Dong, Nana
    Xie, Zulong
    Wang, Wei
    Dai, Jiannan
    Sun, Meng
    Pu, Zhongyue
    Tian, Jinwei
    Yu, Bo
    BMC MEDICAL IMAGING, 2016, 16