Measuring airway dimensions during bronchoscopy using anatomical optical coherence tomography

被引:55
作者
Williamson, J. P. [1 ,3 ]
Armstrong, J. J. [4 ]
McLaughlin, R. A. [4 ]
Noble, P. B. [6 ]
West, A. R. [5 ]
Becker, S. [4 ]
Curatolo, A. [4 ]
Noffsinger, W. J. [1 ]
Mitchell, H. W. [5 ]
Phillips, M. J. [2 ]
Sampson, D. D. [4 ]
Hillman, D. R. [1 ,7 ]
Eastwood, P. R. [1 ,3 ,7 ]
机构
[1] Sir Charles Gairdner Hosp, Dept Pulm Physiol, Perth, WA 6000, Australia
[2] Sir Charles Gairdner Hosp, Dept Resp Med, Perth, WA 6000, Australia
[3] Univ Western Australia, Sch Anat & Human Biol, Nedlands, WA 6009, Australia
[4] Univ Western Australia, Opt Biomed Engn Lab, Sch Elect Elect & Comp Engn, Nedlands, WA 6009, Australia
[5] Univ Western Australia, Sch Biomed Biomol & Chem Sci, Nedlands, WA 6009, Australia
[6] Telethon Inst Child Hlth Res, Div Clin Sci, Perth, WA, Australia
[7] W Australian Sleep Disorders Res Inst, Perth, WA, Australia
基金
英国医学研究理事会;
关键词
Airway dimensions; computed tomography; interventional bronchoscopy; optical coherence tomography; quantitative bronchoscopy; COMPUTED-TOMOGRAPHY; PHARYNGEAL SHAPE; SIZE; INDIVIDUALS; CALIBER; LUMEN; LUNG;
D O I
10.1183/09031936.00041809
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Airway dimensions are difficult to quantify bronchoscopically because of optical distortion and a limited ability to gauge depth. Anatomical optical coherence tomography (aOCT), a novel imaging technique, may overcome these limitations. This study evaluated the accuracy of aOCT against existing techniques in phantom, excised pig and in vivo human airways. Three comparative studies were performed: 1) micrometer-derived area measurements in 10 plastic tubes were compared with aOCT-derived area; 2) aOCT-derived airway compliance curves from excised pig airways were compared with curves derived using an endoscopic technique; and 3) airway dimensions from the trachea to subsegmental bronchi were measured using aOCT in four anaesthetised patients during bronchoscopy and compared with computed tomography (CT) measurements. Measurements in plastic tubes revealed aOCT to be accurate and reliable. In pig airways, aOCT-derived compliance measurements compared closely with endoscopic data. In human airways, dimensions measured with aOCT and CT correlated closely. Bland-Altman plots showed that aOCT diameter and area measurements were higher than CT measurements by 7.6% and 15.1%, respectively. Airway measurements using aOCT are accurate, reliable and compare favourably with existing imaging techniques. Using aOCT with conventional bronchoscopy allows real-time measurement of airway dimensions and could be useful clinically in settings where knowledge of airway calibre is required.
引用
收藏
页码:34 / 41
页数:8
相关论文
共 50 条
  • [21] In vivo imaging of the internal nasal valve during different conditions using optical coherence tomography
    Englhard, Anna S.
    Wiedmann, Maximilian
    Ledderose, Georg J.
    Lemieux, Bryan
    Badran, Alan
    Jing, Joseph C.
    Chen, Zhongping
    Volgger, Veronika
    Wong, Brian J. F.
    LARYNGOSCOPE, 2018, 128 (03) : E105 - E110
  • [22] Calcium evaluation using coronary computed tomography in combination with optical coherence tomography
    Kurogi, Kazumasa
    Ishii, Masanobu
    Ikebe, Sou
    Kaichi, Ryota
    Takae, Masafumi
    Mori, Takayuki
    Komaki, Soichi
    Yamamoto, Nobuyasu
    Tsujita, Kenichi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2023, 39 (09) : 1815 - 1824
  • [23] Calcium evaluation using coronary computed tomography in combination with optical coherence tomography
    Kazumasa Kurogi
    Masanobu Ishii
    Sou Ikebe
    Ryota Kaichi
    Masafumi Takae
    Takayuki Mori
    Soichi Komaki
    Nobuyasu Yamamoto
    Kenichi Tsujita
    The International Journal of Cardiovascular Imaging, 2023, 39 : 1815 - 1824
  • [24] Measuring Intracellular Motion in Cancer Cells using Optical Coherence Tomography
    Zam, Azhar
    Kolios, Michael C.
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS XIII, 2016, 9707
  • [25] Segmental airway phantom for endobronchial optical coherence tomography
    Fung, A.
    Malone, J.
    Tanskanen, A.
    Rehill, M.
    Brace, E.
    Lane, P.
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES XVII, 2024, 12833
  • [26] Distribution of airway narrowing responses across generations and at branching points, assessed in vitro by anatomical optical coherence tomography
    Noble, Peter B.
    McLaughlin, Robert A.
    West, Adrian R.
    Becker, Sven
    Armstrong, Julian J.
    McFawn, Peter K.
    Eastwood, Peter R.
    Hillman, David R.
    Sampson, David D.
    Mitchell, Howard W.
    RESPIRATORY RESEARCH, 2010, 11
  • [27] Imaging and anatomical parameters of the lacrimal punctum and vertical canaliculus using optical coherence tomography
    Hu, Jun
    Xiang, Nan
    Li, Gui Gang
    Luo, Ban
    Zhang, Yuan
    Zhu, Yingting
    Liu, Rong
    INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2021, 18 (12): : 2493 - 2499
  • [28] Measuring skin aging using optical coherence tomography in vivo: a validation study
    Trojahn, Carina
    Dobos, Gabor
    Richter, Claudia
    Blume-Peytavi, Ulrike
    Kottner, Jan
    JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (04)
  • [29] Measuring acquired ocular torsion with optical coherence tomography
    Borgman, Christopher J.
    Haynes, Jessica A.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2021, 104 (01) : 132 - 134
  • [30] Quantitative Evaluation of Adult Subglottic Stenosis Using Intraoperative Long-range Optical Coherence Tomography
    Sharma, Giriraj K.
    Loy, Anthony Chin
    Su, Erica
    Jing, Joe
    Chen, Zhongping
    Wong, Brian J-F.
    Verma, Sunil
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2016, 125 (10) : 815 - 822