Optimization of experimental parameters in single-drop microextraction-gas chromatography-mass spectrometry for the determination of periodate by the Malaprade reaction, and its application to ethylene glycol

被引:18
作者
Gupta, Manju [1 ]
Jain, Archana [1 ]
Verma, Krishna K. [1 ]
机构
[1] Rani Durgavati Univ, Dept Chem, Jabalpur 482001, Madhya Pradesh, India
关键词
single-drop microextraction; immersion; headspace; periodate; ethylene glycol; GC-MS;
D O I
10.1016/j.talanta.2006.05.083
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The aim of present work was to optimize the experimental parameters in single drop microextraction under solution immersion (SDME) and headspace (HS-SDME) extraction modes for the determination of periodate using guaifenesine [3-(2'-methoxyphenoxy)-1,2-propane diol] and norephedrine (phenylpropanolamine) as new and alternative reagents for the Malaprade reaction. The reactions were complete within 5 min resulting in the formation of 2-(2'-methoxyphenoxy)-acetaldehyde and benzaldehyde, respectively. SDME/HS-SDME of oxidation products with 2 mu l of anisole or 1 mu l of toluene, respectively, has permitted the determination of periodate at mu g l(-1) concentration levels. The results indicated that HS-SDME (range 0.01-10 mg l(-1), r(2) = 0.9990; limit of detection 1.55 mu g l(-1)) was more sensitive than SDME (range 0.05-50 mg l(-1), r(2) = 0.9984; limit of detection 3.42 mu g l(-1)), and was inexpensive, rapid and convenient. Tolerance of excess of iodate has permitted the application of this method in the determination of ethylene glycol in motor oil; the average recovery on spiked sample was 98.6% with R.S.D. of 4.2%. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1039 / 1046
页数:8
相关论文
共 59 条
[1]   Simultaneous kinetic-spectrophotometric determination of periodate-bromate and iodate-bromate mixtures using the H-point standard addition method [J].
Afkhami, A ;
Zarei, AR .
TALANTA, 2003, 60 (01) :63-71
[2]   Kinetic determination of periodate based on its reaction with ferroin and its application to the indirect determination of ethylene glycol and glycerol [J].
Afkhami, A ;
Mosaed, F .
MICROCHEMICAL JOURNAL, 2001, 68 (01) :35-40
[3]   Spectrophotometric determination of periodate and iodate by a differential kinetic method [J].
Afkhami, A ;
Zarei, AR .
TALANTA, 2001, 53 (04) :815-821
[4]  
[Anonymous], TRENDS ANAL CHEM
[5]   Immersed solvent microextraction of phenol and chlorophenols from water samples followed by gas chromatography-mass spectrometry [J].
Bagheri, H ;
Saber, A ;
Mousavi, SR .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1046 (1-2) :27-33
[6]   Trace analysis of explosives in seawater using solid-phase microextraction and gas chromatography ion trap mass spectrometry [J].
Barshick, SA ;
Griest, WH .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :3015-3020
[7]  
BRUICE PY, 2001, ORGANIC CHEM, P805
[8]  
CANWELL FF, 2002, WILSON WILSONS COMPR, V37, P297
[9]   Headspace single-drop microextration for the detection of organotin compounds [J].
Colombini, V ;
Bancon-Montigny, C ;
Yang, L ;
Maxwell, P ;
Sturgeon, RE ;
Mester, Z .
TALANTA, 2004, 63 (03) :555-560
[10]   Single drop microextraction or solid phase microextraction-gas chromatography-mass spectrometry for the determination of iodine in pharmaceuticals, iodized salt, milk powder and vegetables involving conversion into 4-iodo-N,N-dimethylaniline [J].
Das, P ;
Gupta, M ;
Jain, A ;
Verma, KK .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1023 (01) :33-39