Evaluating a protocol for testing a fire-resistant oil-spill containment boom

被引:9
作者
Bitting, KR [1 ]
机构
[1] US Coast Guard Res & Dev, Groton, CT 06340 USA
关键词
in situ burning; diesel fuel; fire-resistant booms; oil spills; pool fires;
D O I
10.1016/S1353-2561(00)00050-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Most response plans for in situ burning of oil at sea call for the use of a fire-resistant boom to contain the oil during a burn. Presently, there is no standard method for the user of a fire-resistant boom to evaluate the anticipated performance of different booms. The ASTM F-20 committee has developed a draft standard, "Standard Guide for in situ Burning of Oil Spills on Water: Fire-Resistant Containment Boom"; however, the draft provides only general guidelines and does not specify the details of the test procedure. Utilizing the guidelines in the draft standard, a series of experiments were conducted to evaluate a protocol for testing the ability of fire-resistant booms to withstand both fire and waves. (C) 2000 Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:337 / 339
页数:3