RF plasma-polymerization of acetylene:: Correlation between plasma diagnostics and deposit characteristics

被引:56
|
作者
Le Du, Gwenaelle
Celini, Natacha
Bergaya, Faiza
Poncin-Epaillard, Fabienne
机构
[1] Univ Maine, CNRS, UMR 6120, Lab Polymeres Colloides & Interfaces, F-72085 Le Mans, France
[2] Univ Orleans, CRMD, UMR 6619, F-45071 Orleans 2, France
来源
SURFACE & COATINGS TECHNOLOGY | 2007年 / 201卷 / 12期
关键词
acetylene plasma; hydrophobic coating; optical emission spectroscopy;
D O I
10.1016/j.surfcoat.2006.10.025
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Clay-polymer nanocomposites are developed to obtain better mechanical, electrical or permeability properties controlled by the interaction energy between polymer chains and filler dispersed in polymeric blend. The dispersion of clay particles in polymers was achieved by chemical pre-treatment of the individual clay layers. The technique of acetylene plasma deposition is proposed as an alternative route to alter hydrophilic character of the clay. Since the clay is a complex material, plasma-polymer, coated silicon wafer was used as reference and characterized by different surface techniques. Different plasma parameters were chosen to lead to the most hydrophobic coating. Optical Emission Spectroscopy (OES) was also used to establish the relationship between the plasma chemistry and the properties of the deposit layer. (c) 2006 Elsevier B.V All rights reserved.
引用
收藏
页码:5815 / 5821
页数:7
相关论文
共 50 条
  • [31] Spectroscopic diagnostics of a pulsed arc plasma in the presence of acetylene
    Smyaglikov, I. P.
    Chekan, N. M.
    Akula, I. P.
    Pobol, I. L.
    Rajczyk, J.
    VACUUM, 2013, 90 : 165 - 169
  • [32] A correlation between particle growth and spatiotemporal RF plasma structure
    Kamata, T.
    Kakuta, S.
    Yamaguchi, Y.
    Makabe, T.
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 1994, 3 (03): : 310 - 313
  • [33] STUDY OF A RF PLANAR MAGNETRON SPUTTERING DISCHARGE - DISCHARGE CHARACTERISTICS AND PLASMA DIAGNOSTICS
    JOUAN, PY
    LEMPERIERE, G
    VACUUM, 1994, 45 (01) : 89 - 95
  • [34] DEPOSITION OF PLASMA-POLYMERIZED ACETYLENE BY AN INTENSE PULSED RF PLASMA SOURCE
    PEDROW, PD
    NASIRUDDIN, AM
    MAHALINGAM, R
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1990, 18 (06) : 945 - 947
  • [35] Recovery of the characteristics of plasma turbulence from the radial correlation backscattering diagnostics
    Gusakov, E. Z.
    Krutkin, O. L.
    PLASMA PHYSICS REPORTS, 2017, 43 (06) : 605 - 613
  • [36] Recovery of the characteristics of plasma turbulence from the radial correlation backscattering diagnostics
    E. Z. Gusakov
    O. L. Krutkin
    Plasma Physics Reports, 2017, 43 : 605 - 613
  • [37] Macroscopic techniques for RF plasma reactor diagnostics
    Chazot, O
    Diemiaszonek, R
    Garnier, M
    Trassy, C
    PROGRESS IN PLASMA PROCESSING OF MATERIALS 1997, 1997, : 239 - 246
  • [38] Tuned Electrostatic Probe for RF Plasma Diagnostics
    Cirino, Giuseppe A.
    Castro, Raul M.
    Pisani, Marcelo B.
    Verdonck, Patrick
    2013 28TH SYMPOSIUM ON MICROELECTRONICS TECHNOLOGY AND DEVICES (SBMICRO 2013), 2013,
  • [39] ACOUSTOOPTIC RF SPECTRUM ANALYZER FOR PLASMA DIAGNOSTICS
    IRBY, JH
    BEALS, D
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1985, 56 (05): : 993 - 993
  • [40] Correlation measurements for fusion plasma diagnostics
    Pazsit, I
    FUSION TECHNOLOGY, 1996, 30 (03): : 326 - 336