Reference values for structure emissions measured on site in new residential buildings in Finland

被引:38
作者
Jarnstrom, H.
Saarela, K.
Kalliokoski, P.
Pasanen, A. -L.
机构
[1] VTT, FIN-02044 Espoo, Finland
[2] Univ Kuopio, Dept Environm Sci, FIN-70211 Kuopio, Finland
[3] Finnish Inst Occupat Hlth, FIN-70701 Kuopio, Finland
基金
芬兰科学院;
关键词
material emission; VOC ammonia; formaldehyde; reference value;
D O I
10.1016/j.atmosenv.2006.11.033
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A 3-year research project was established in 1999 to create numerical reference data for material emissions during the time of construction and during the first year. Seven buildings, representing the present construction practice in Finland, were investigated. Material emissions were measured by using the field and laboratory cell (FLEC) during the time of construction, in the newly finished, and in the 6- and 12-month-old buildings. The emission rates for volatile organic compounds (VOCs), formaldehyde, and ammonia were determined. The highest total VOCs (TVOC) emissions were measured in the newly finished buildings from the ceiling structure and from some of the PVC floor coverings. These emissions were up to 1300-2000 mu g m(-2) h(-1). Individual VOCs with emission rates above 50 mu g m(-2) h(-1) included 2-(2-butoxyethoxy) ethanol and its acetate, C4-C16-substituted alkylbenzenes, and xylenes. The mean TVOC emission decreased at least to the Finnish M1-class level (200 mu g m(-2) h(-1)) from all surfaces and in all the buildings in 6-12 months. The ammonia and formaldehyde emissions from the ceiling structure were 20-60 mu g m(-2) h(-1) in the newly finished buildings and the M1-levels (30/50 mu g m(-2) h(-1)) were exceeded in some cases. These emissions even increased in some buildings during the follow-up period indicating the difference between emissions measured in the laboratory and on site from real structures. Reference values based on the means and 95th percentile are presented to be utilised in both quality control and while investigating indoor air quality problems which are Suspected to be caused by a defect structure. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2290 / 2302
页数:13
相关论文
共 39 条
[1]  
[Anonymous], 2006, ISO 16000-9
[2]  
ASTM, 1997, D511697 ASTM
[3]  
BORNEHAG CG, 1991, INDOOR CLIMATE DALEN
[4]   Volatile organic pollutants in new and established buildings in Melbourne, Australia [J].
Brown, SK .
INDOOR AIR, 2002, 12 (01) :55-63
[5]  
*EUR COLL ACT, 1993, 13 EUR COLL ACT COMM
[6]  
*EUR COLL ACT, 1991, 8 EUR COLL ACT COM E
[7]  
*FIS1AQ, 2001, CLASS IND CLIM 2000
[8]  
GUNNARSEN L, 1993, P 6 INT C IND AIR QU, V2, P501
[9]  
GUSTAFSSON H, 1990, KEMISK EMISSION FRAN, P25
[10]   MODELS FOR ESTIMATING ORGANIC EMISSIONS FROM BUILDING-MATERIALS - FORMALDEHYDE EXAMPLE [J].
HAWTHORNE, AR ;
MATTHEWS, TG .
ATMOSPHERIC ENVIRONMENT, 1987, 21 (02) :419-424