Optimal port placement and enhanced guidance in robotically assisted cardiac surgery

被引:20
作者
Bauernschmitt, R. [1 ]
Feuerstein, M.
Traub, J.
Schirmbeck, Eva U.
Klinker, G.
Lange, R.
机构
[1] German Heart Ctr, Clin Cardiovasc Surg, Munich, Germany
[2] Tech Univ Munich, Munich, Germany
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2007年 / 21卷 / 04期
关键词
surgical navigation; port placement; computer assisted heart surgery;
D O I
10.1007/s00464-006-9057-z
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Optimal port placement and enhanced guidance in robotically assisted cardiac surgery is required to improve preoperative planning and intraoperative navigation. Methods: Offline optimal port placement is planned on a three-dimensional virtual reconstruction of the patient's computed tomography scan. Using this data, an accurate in vivo port placement can be performed, which is achieved by augmented reality techniques superimposing virtual models of the thorax and the teleoperator arms on top of the real worldview. Results: A new system incorporating both port placement planning and intraoperative navigation in robotically assisted minimally invasive heart surgery was established to aid the operative workflow. A significant reduction of operation time by improved planning and intraoperative support is anticipated. Conclusions: The enhanced intraciperative orientation possibilities may lead to further decrease in operation time and have the continuing ability to improve quality.
引用
收藏
页码:684 / 687
页数:4
相关论文
共 7 条
[1]   Design of a component-based augmented reality framework [J].
Bauer, M ;
Bruegge, B ;
Klinker, G ;
MacWilliams, A ;
Reicher, T ;
Riss, S ;
Sandor, C ;
Wagner, M .
IEEE AND ACM INTERNATIONAL SYMPOSIUM ON AUGMENTED REALITY, PROCEEDINGS, 2001, :45-54
[2]   The Janus syndrome: A perspective computer-enhanced robotic cardiac on a new era of surgery [J].
Boyd, WD ;
Stahl, KD .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (03) :625-630
[3]  
COSTEMANIERE E, 2002, LECT NOTES CONTROL I, V8, P424
[4]   Minimally invasive abdominal surgery: lux et veritas past, present, and future [J].
Harrell, AG ;
Heniford, BT .
AMERICAN JOURNAL OF SURGERY, 2005, 190 (02) :239-243
[5]   Computer-enhanced "robotic" cardiac surgery: Experience in 148 patients [J].
Mohr, FW ;
Falk, V ;
Diegeler, A ;
Walther, T ;
Gummert, JF ;
Bucerius, J ;
Jacobs, S ;
Autschbach, R .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 121 (05) :842-853
[6]   Clinical utility and cost-effectiveness of interactive image-guided craniotomy: Clinical comparison between conventional and image-guided meningioma surgery [J].
Paleologos, TS ;
Wadley, JP ;
Kitchen, ND ;
Thomas, DGT .
NEUROSURGERY, 2000, 47 (01) :40-47
[7]   Clinical use of stereoscopic X-ray positioning of patients treated with conformal radiotherapy for prostate cancer [J].
Soete, G ;
Verellen, D ;
Michielsen, D ;
Vinh-Hung, V ;
Van de Steene, J ;
Van den Berge, D ;
De Roover, P ;
Keuppens, F ;
Storme, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 54 (03) :948-952