Forensic 3D printing from micro-CT for court use- process validation

被引:12
|
作者
Baier, Waltraud [1 ]
Norman, Danielle G. [1 ]
Donnelly, Michael J. [1 ]
Williams, Mark A. [1 ]
机构
[1] Univ Warwick, Coventry CV4 7AL, W Midlands, England
关键词
3D printing; Additive manufacturing; Forensic evidence; Micro-CT; Surface comparison; COMPUTED-TOMOGRAPHY; DIMENSIONAL ACCURACY; TRAUMA; VOLUME; AGE;
D O I
10.1016/j.forsciint.2020.110560
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Forensic application of 3D scanning and printing technology is gaining momentum with 3D printed evidence starting to be produced for court. However, the processes for creating these forensic 3D models requires still rigorous assessment to ensure they adhere to the relevant legal standards. Although, previous work has examined the accuracy of 3D prints created from medical grade Computed Tomography (CT), no such assessment has been carried out for Micro Computed Tomography (micro-CT) which offers superior resolution and the ability to capture forensically relevant injuries. This study aimed to quantify the error rates associated with forensic 3D printed models and toolmarks, created using three different printing technologies, based on micro-CT data. Overall, 3D printed models, based on micro-CT scans, replicate bone surface geometry to sub-millimetre accuracy (<0.62 mm for overall shape and <0.36 mm for toolmarks). However, there were significant differences between the printing technology employed (mean errors of -0.3%, -0.8%, and 0.7% for shape geometry and -0.8%, 14.1%, and 0.7% for toolmark geometry for Printers 1-3 respectively). Where possible, the authors recommend micro-CT imaging for producing forensic 3D printed bone models particularly when injuries are present. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Bioceramic granulates for use in 3D printing:: Process engineering aspects
    Irsen, St. H.
    Leukers, B.
    Hoeckling, Chr.
    Tille, C.
    Seitz, H.
    MATERIALWISSENSCHAFT UND WERKSTOFFTECHNIK, 2006, 37 (06) : 533 - 537
  • [42] High-resolution 3D micro-CT imaging of breast microcalcifications: a preliminary analysis
    Willekens, Inneke
    Van de Casteele, Elke
    Buls, Nico
    Temmermans, Frederik
    Jansen, Bart
    Deklerck, Rudi
    de Mey, Johan
    BMC CANCER, 2014, 14
  • [43] Effect of weaving parameters on fiber structure of 3D woven preforms: A Micro-CT investigation
    Yang, Zhi
    Jiao, Yanan
    Xie, Junbo
    Jiao, Wei
    Chen, Li
    Zhu, Liping
    Du, Xuefei
    JOURNAL OF COMPOSITE MATERIALS, 2022, 56 (16) : 2609 - 2620
  • [44] 3D geometric modeling of three-thread fleece fabric based on micro-CT
    Yu, Yuelin
    Wu, Weili
    Chen, Weilai
    Shao, Yiqin
    Zhu, Chunhong
    Gu, Xuefeng
    Hu, Shengchao
    TEXTILE RESEARCH JOURNAL, 2023, 93 (9-10) : 1928 - 1937
  • [45] Anatomical Study of the Retrodural Space of Okada in the Cervical Region: 3D Micro-CT Findings
    Cho, Tae-Hyeon
    Jun, Byongnam
    Kim, Shin Hyung
    Yang, Hun-Mu
    CLINICAL ANATOMY, 2025,
  • [46] 3D visualization of the human anterior cruciate ligament combining micro-CT and histological analysis
    Annapaola Parrilli
    Alberto Grassi
    Federica Orellana
    Roberta Lolli
    Gregorio Marchiori
    Matteo Berni
    Milena Fini
    Nicola Francesco Lopomo
    Stefano Zaffagnini
    Surgical and Radiologic Anatomy, 2024, 46 : 249 - 258
  • [47] 3D Reconstruction of Peripheral Nerves Based on Calcium Chloride Enhanced Micro-CT Images
    Zhong, Yingchun
    Luo, Peng
    Gao, Junli
    Qi, Jian
    Li, Fang
    Yan, Liwei
    Wang, Liping
    ANALYTICAL AND QUANTITATIVE CYTOPATHOLOGY AND HISTOPATHOLOGY, 2019, 41 (05): : 159 - 168
  • [48] 3D visualization of the human anterior cruciate ligament combining micro-CT and histological analysis
    Parrilli, Annapaola
    Grassi, Alberto
    Orellana, Federica
    Lolli, Roberta
    Marchiori, Gregorio
    Berni, Matteo
    Fini, Milena
    Lopomo, Nicola Francesco
    Zaffagnini, Stefano
    SURGICAL AND RADIOLOGIC ANATOMY, 2024, 46 (02) : 249 - 258
  • [49] Micro-CT 3D Visualization Method of Different Species' Osseous Lacuna Morphological Structure
    Zhu Y.
    Xie R.
    Zhang H.
    Gao B.
    Liu X.
    Han L.
    Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2022, 53 (09): : 374 - 381
  • [50] Micro-CT imaging of Thiel-embalmed and iodine-stained human temporal bone for 3D modeling
    Halm, Sebastian
    Haberthuer, David
    Eppler, Elisabeth
    Djonov, Valentin
    Arnold, Andreas
    JOURNAL OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2021, 50 (01)