Optimizing the signal-to-noise ratio of biphoton distribution measurements

被引:14
|
作者
Reichert, Matthew [1 ]
Defienne, Hugo [1 ]
Fleischer, Jason W. [1 ]
机构
[1] Princeton Univ, Dept Elect Engn, Princeton, NJ 08544 USA
关键词
PODOLSKY-ROSEN PARADOX; ENHANCED SENSITIVITY; LIGHT; EMCCDS; PAIRS;
D O I
10.1103/PhysRevA.98.013841
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Single-photon-sensitive cameras can now be used as massively parallel coincidence counters for entangled photon pairs. This enables measurement of biphoton joint probability distributions with orders-of-magnitude greater dimensionality and faster acquisition speeds than traditional raster scanning of point detectors; to date, however, there has been no general formula available to optimize data collection. Here we analyze the dependence of such measurements on count rate, detector noise properties, and threshold levels. We derive expressions for the biphoton joint probability distribution and its signal-to-noise ratio (SNR), valid beyond the low-count regime up to detector saturation. The analysis gives operating parameters for global optimum SNR that may be specified prior to measurement. We find excellent agreement with experimental measurements within the range of validity and discuss discrepancies with the theoretical model for high thresholds. This work enables optimized measurement of the biphoton joint probability distribution in high-dimensional joint Hilbert spaces.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Optimizing the signal-to-noise ratio for the PELAN system
    Womble, PC
    Vourvopoulos, G
    Paschal, J
    Novikov, I
    Chen, GY
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 470 - 473
  • [2] A model of the probability distribution of the signal-to-noise ratio estimated from BER measurements
    Matricciani, Emilio
    2011 IEEE VEHICULAR TECHNOLOGY CONFERENCE (VTC FALL), 2011,
  • [3] SIGNAL-TO-NOISE RATIO OPTIMIZATION OF ATOMIC SPECTROMETRIC MEASUREMENTS
    INGLE, JD
    BOWER, NW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1976, 172 (SEP3): : 11 - 11
  • [4] Optimizing the signal-to-noise ratio for direct-detection BOTDA
    Wang, Sheng
    Yang, Zhisheng
    Soto, Marcelo A.
    Thevenaz, Luc
    SEVENTH EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS (EWOFS 2019), 2019, 11199
  • [5] Optimizing the intrinsic signal-to-noise ratio of MRI strip detectors
    Kumar, Ananda
    Bottomley, Paul A.
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (01) : 157 - 166
  • [6] ON OPTIMIZING SIGNAL-TO-NOISE RATIO OF 2-STATE EXPERIMENTS
    BOWMAN, JD
    VANDERLEEDEN, JC
    NUCLEAR INSTRUMENTS & METHODS, 1970, 85 (01): : 19 - +
  • [7] Optimizing the Signal-to-Noise Ratio for Biosensing with Carbon Nanotube Transistors
    Heller, Iddo
    Mannik, Jaan
    Lemay, Serge G.
    Dekker, Cees
    NANO LETTERS, 2009, 9 (01) : 377 - 382
  • [8] 'Signal-to-Noise Ratio'
    McCooey, D
    POETRY REVIEW, 1999, 89 (01): : 73 - 73
  • [9] Influence of the signal-to-noise ratio on the accuracy of IOLMaster measurements
    Suto, Chikako
    Sato, Chdaki
    Shimarnura, Erniko
    Toshida, Hiroshi
    Ichikawa, Kazuo
    Hori, Sadao
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (12): : 2062 - 2066