Variation in the amount of petrolatum preparation applied at patch testing

被引:32
作者
Bruze, Magnus [1 ]
Frick-Engfeldt, Malin [1 ]
Gruvberger, Birgitta [1 ]
Isaksson, Marlene [1 ]
机构
[1] Lund Univ, Malmo Univ Hosp, Dept Occupat & Environm Dermatol, SE-20502 Malmo, Sweden
关键词
allergic contact dermatitis; contact allergy; dose/area; Finn Chamber (R); inter-individual; intra-individual; standard series; weighing;
D O I
10.1111/j.1600-0536.2007.00985.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
The elicitation of a positive patch test reaction in a given individual depends upon the dose of the sensitizer applied, the patch test technique and the occlusion time. The dose is determined by the concentration and volume/amount of test preparation applied. If the same amount/volume of a test preparation is applied all the time with the same test technique (same area of skin) and occlusion time, it is appropriate to use concentration as a dose parameter. Most contact sensitizers are incorporated in petrolatum (pet.). With pet. as vehicle, it is impossible to repeatedly apply an exact volume/amount. This study was performed to investigate the inter- and intra-individual variation of pet. preparation applied at patch testing by 3 technicians. Weighing demonstrated that the 3 technicians had about the same precision in their pet. application. The investigation demonstrates that there is both an inter-individual (statistically significant) and intra-individual variation in the amounts of pet. applied at patch testing for the 3 technicians. Presently, there is no recommendation on what amount of pet. preparation to apply, which merits a decision to be taken based on thorough investigations on the appropriate volumes of pet. preparation to be applied in various patch test systems.
引用
收藏
页码:38 / 42
页数:5
相关论文
共 14 条
[1]  
Andersen KE, 1996, ACTA DERM-VENEREOL, V76, P136
[2]  
Antoine J L, 1988, Derm Beruf Umwelt, V36, P191
[3]   HIGH-FREQUENCY OF CONTACT ALLERGY TO GOLD SODIUM THIOSULFATE - AN INDICATION OF GOLD ALLERGY [J].
BJORKNER, B ;
BRUZE, M ;
MOLLER, H .
CONTACT DERMATITIS, 1994, 30 (03) :144-151
[4]   Recommendation to include methyldibromo glutaronitrile in the European standard patch test series [J].
Bruze, M ;
Goossens, A ;
Gruvberger, B .
CONTACT DERMATITIS, 2005, 52 (01) :24-28
[5]  
BRUZE M, 1988, ACTA DERM-VENEREOL, V68, P361
[6]   Thoughts on sensitizers in a standard patch test series [J].
Bruze, M ;
Condé-Salazar, L ;
Goossens, A ;
Kanerva, L ;
White, IR .
CONTACT DERMATITIS, 1999, 41 (05) :241-250
[7]   STUDIES ON PURITY AND STABILITY OF PHOTOPATCH TEST SUBSTANCES [J].
BRUZE, M ;
FREGERT, S .
CONTACT DERMATITIS, 1983, 9 (01) :33-39
[8]   FINN CHAMBER PATCH TEST TECHNIQUE [J].
FISCHER, T ;
MAIBACH, H .
CONTACT DERMATITIS, 1984, 11 (03) :137-140
[9]  
FRIEDMANN PS, 1983, CLIN EXP IMMUNOL, V53, P709
[10]   Stability of corticosteroid patch test preparations [J].
Isaksson, M ;
Gruvberger, B ;
Persson, L ;
Bruze, M .
CONTACT DERMATITIS, 2000, 42 (03) :144-148