The impact of manual threshold selection in medical additive manufacturing

被引:52
作者
van Eijnatten, Maureen [1 ]
Koivisto, Juha [1 ,2 ]
Karhu, Kalle [2 ]
Forouzanfar, Tymour [1 ]
Wolff, Jan [1 ]
机构
[1] Vrije Univ Amsterdam Med Ctr, Dept Oral & Maxillofacial Surg Oral Pathol, Innovat Lab 3D, De Boelelaan 1118, NL-1081 HV Amsterdam, Netherlands
[2] Planmeca Ltd, Res & Technol, Helsinki, Finland
关键词
Additive manufacturing; Three-dimensional (3D) printing; Computed tomography (CT); Medical imaging; Segmentation; Thresholding; HOUNSFIELD UNITS; BEAM; ACCURACY; RECONSTRUCTIONS; DENSITY;
D O I
10.1007/s11548-016-1490-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Medical additive manufacturing requires standard tessellation language (STL) models. Such models are commonly derived from computed tomography (CT) images using thresholding. Threshold selection can be performed manually or automatically. The aim of this study was to assess the impact of manual and default threshold selection on the reliability and accuracy of skull STL models using different CT technologies. One female and one male human cadaver head were imaged using multi-detector row CT, dual-energy CT, and two cone-beam CT scanners. Four medical engineers manually thresholded the bony structures on all CT images. The lowest and highest selected mean threshold values and the default threshold value were used to generate skull STL models. Geometric variations between all manually thresholded STL models were calculated. Furthermore, in order to calculate the accuracy of the manually and default thresholded STL models, all STL models were superimposed on an optical scan of the dry female and male skulls ("gold standard"). The intra- and inter-observer variability of the manual threshold selection was good (intra-class correlation coefficients > 0.9). All engineers selected grey values closer to soft tissue to compensate for bone voids. Geometric variations between the manually thresholded STL models were 0.13 mm (multi-detector row CT), 0.59 mm (dual-energy CT), and 0.55 mm (cone-beam CT). All STL models demonstrated inaccuracies ranging from -0.8 to +1.1 mm (multi-detector row CT), -0.7 to +2.0 mm (dual-energy CT), and -2.3 to +4.8 mm (cone-beam CT). This study demonstrates that manual threshold selection results in better STL models than default thresholding. The use of dual-energy CT and cone-beam CT technology in its present form does not deliver reliable or accurate STL models for medical additive manufacturing. New approaches are required that are based on pattern recognition and machine learning algorithms.
引用
收藏
页码:607 / 615
页数:9
相关论文
共 27 条
[1]   Computer-guided rapid-prototyped templates for segmental mandibular osteotomies: a preliminary report [J].
Abou-ElFetouh, Adel ;
Barakat, Ahmed ;
Abdel-Ghany, Khaled .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2011, 7 (02) :187-192
[2]   INTRACLASS CORRELATION COEFFICIENT AS A MEASURE OF RELIABILITY [J].
BARTKO, JJ .
PSYCHOLOGICAL REPORTS, 1966, 19 (01) :3-&
[3]  
CLACK R, 1991, LECT NOTES COMPUT SC, V511, P45, DOI 10.1007/BFb0033741
[4]  
Silva IMDC, 2012, BRAZ ORAL RES, V26, P550
[5]   Effect of scattered radiation on image noise in cone beam CT [J].
Endo, M ;
Tsunoo, T ;
Nakamori, N ;
Yoshida, K .
MEDICAL PHYSICS, 2001, 28 (04) :469-474
[6]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[7]  
Gibson I., 2021, Additive Manufacturing Technologies, V17
[8]   Inaccuracies in additive manufactured medical skull models caused by the DICOM to STL conversion process [J].
Huotilainen, Eero ;
Jaanimets, Risto ;
Valasek, Jiri ;
Marcian, Petr ;
Salmi, Mika ;
Tuomi, Jukka ;
Makitie, Antti ;
Wolff, Jan .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2014, 42 (05) :E259-E265
[9]   Imaging requirements for medical applications of additive manufacturing [J].
Huotilainen, Eero ;
Paloheimo, Markku ;
Salmi, Mika ;
Paloheimo, Kaija-Stiina ;
Bjorkstrand, Roy ;
Tuomi, Jukka ;
Markkola, Antti ;
Makitie, Antti .
ACTA RADIOLOGICA, 2014, 55 (01) :78-85
[10]   Dual-Energy CT: General Principles [J].
Johnson, Thorsten R. C. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) :S3-S8