A highly sensitive colorimetric metalloimmunoassay based on copper-mediated etching of gold nanorods

被引:15
作者
Cheng, Fangbin [1 ]
Chen, Zhaopeng [2 ]
Zhang, Zhiyang [2 ]
Chen, Lingxin [2 ,3 ]
机构
[1] Yantai Univ, Ocean Sch, Yantai 264005, Peoples R China
[2] Chinese Acad Sci, Yantai Inst Coastal Zone Res, Key Lab Coastal Environm Proc & Ecol Remediat, Yantai 264003, Peoples R China
[3] Yantai Univ, Coll Chem & Chem Engn, Yantai 264005, Peoples R China
关键词
PEROXIDASE-LIKE ACTIVITY; IMMUNOSORBENT-ASSAY; VISUAL DETECTION; HUMAN SERUM; IMMUNOASSAY; NANOPARTICLES; PROTEINS; ELISA; IONS; NANOSTRUCTURES;
D O I
10.1039/c5an02276b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive colorimetric metalloimmunoassay with a detection limit of 0.15 ng ml(-1) for human IgG based on coppermediated etching of gold nanorods was proposed. The assay is more sensitive than traditional ELISA, electrochemical metalloimmunoassay and HRP mimic nanomaterial tag-based immunoassay.
引用
收藏
页码:1918 / 1921
页数:4
相关论文
共 43 条
  • [1] Double-codified gold nanolabels for enhanced immunoanalysis
    Ambrosi, Adriano
    Castaneda, Maria Teresa
    Killard, Anthony J.
    Smyth, Malcolm R.
    Alegret, Salvador
    Merkoci, Arben
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (14) : 5232 - 5240
  • [2] Blumenthal S, 2009, PERSPECT BIOL MED, V52, P343, DOI 10.1353/pbm.0.0091
  • [3] Colorimetric Assay for Lead Ions Based on the Leaching of Gold Nanoparticles
    Chen, Yi-You
    Chang, Huan-Tsung
    Shiang, Yen-Chun
    Hung, Yu-Lun
    Chiang, Cheng-Kang
    Huang, Chih-Ching
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (22) : 9433 - 9439
  • [4] ELISA SOLID-PHASE - PARTIAL DENATURATION OF COATING ANTIBODY YIELDS A MORE EFFICIENT SOLID-PHASE
    CONRADIE, JD
    GOVENDER, M
    VISSER, L
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1983, 59 (03) : 289 - 299
  • [5] An electrochemical metalloimmunoassay based on a colloidal gold label
    Dequaire, M
    Degrand, C
    Limoges, B
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (22) : 5521 - 5528
  • [6] Single-Molecule ELISA
    Ekins, Roger
    Kelso, David
    [J]. CLINICAL CHEMISTRY, 2011, 57 (03) : 372 - 375
  • [7] ENZYME-AMPLIFIED LANTHANIDE LUMINESCENCE FOR ENZYME DETECTION IN BIOANALYTICAL ASSAYS
    EVANGELISTA, RA
    POLLAK, A
    TEMPLETON, EFG
    [J]. ANALYTICAL BIOCHEMISTRY, 1991, 197 (01) : 213 - 224
  • [8] Colorimetric filtrations of metal chelate precipitations for the quantitative determination of nickel(II) and lead(II)
    Feng, Liang
    Zhang, Yue
    Wen, Liying
    Chen, Liang
    Shen, Zheng
    Guan, Yafeng
    [J]. ANALYST, 2011, 136 (20) : 4197 - 4203
  • [9] Enzyme Immunoassay and Enzyme-Linked Immunosorbent Assay
    Gan, Stephanie D.
    Patel, Kruti R.
    [J]. JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2013, 133 (09) : E10 - E12
  • [10] Magnetite Nanoparticle-Linked Immunosorbent Assay
    Gao, Lizeng
    Wu, Jiamin
    Lyle, Sarah
    Zehr, Keith
    Cao, Liangliang
    Gao, Di
    [J]. JOURNAL OF PHYSICAL CHEMISTRY C, 2008, 112 (44) : 17357 - 17361