The accuracy of pharmacokinetic parameter measurement in DCE-MRI of the breast at 3 T

被引:76
作者
Di Giovanni, P. [1 ]
Azlan, C. A. [1 ,2 ]
Ahearn, T. S. [1 ]
Semple, S. I. [3 ]
Gilbert, F. J. [1 ]
Redpath, T. W. [1 ]
机构
[1] Univ Aberdeen, Aberdeen Biomed Imaging Ctr, Aberdeen, Scotland
[2] Univ Malaya, Fac Med, Dept Biomed Imaging, Kuala Lumpur, Malaysia
[3] Univ Edinburgh, Edinburgh, Midlothian, Scotland
关键词
CONTRAST-ENHANCED MRI; TEMPORAL SAMPLING REQUIREMENTS; TRACER KINETICS; CANCER; TUMORS; CHEMOTHERAPY; PERMEABILITY; SEQUENCES; VOLUME;
D O I
10.1088/0031-9155/55/1/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this work is to quantify the accuracy of pharmacokinetic parameter measurement in DCE-MRI of breast cancer at 3 T in relation to three sources of error. Individually, T1 measurement error, temporal resolution and transmitted RF field inhomogeneity are considered. Dynamic contrast enhancement curves were simulated using standard acquisition parameters of a DCE-MRI protocol. Errors on pre-contrast T1 due to incorrect RF spoiling were considered. Flip angle errors were measured and introduced into the fitting routine, and temporal resolution was also varied. The error in fitted pharmacokinetic parameters, K(trans) and v(e), was calculated. Flip angles were found to be reduced by up to 55% of the expected value. The resultant errors in our range of K(trans) and v(e) were found to be up to 66% and 74%, respectively. Incorrect T1 estimation results in K(trans) and v(e) errors up to 531% and 233%, respectively. When the temporal resolution is reduced from 10 to 70 s K(trans) drops by up to 48%, while v(e) shows negligible variation. In combination, uncertainties in tissue T1 map and applied flip angle were shown to contribute to errors of up to 88% in K(trans) and 73% in v(e). These results demonstrate the importance of high temporal resolution, accurate T1 measurement and good B1 homogeneity.
引用
收藏
页码:121 / 132
页数:12
相关论文
共 30 条
[1]   The effects of renal variation upon measurements of perfusion and leakage volume in breast tumours [J].
Ahearn, TS ;
Staff, RT ;
Redpath, TW ;
Semple, SIK .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (10) :2041-2051
[2]  
AZLAN CA, 2009, P ISMRM 17 ANN M HON, P2106
[3]   Microcirculation and microvasculature in breast tumors: Pharmacokinetic analysis of dynamic MR image series [J].
Brix, G ;
Kiessling, F ;
Lucht, R ;
Darai, S ;
Wasser, K ;
Delorme, S ;
Griebel, J .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (02) :420-429
[4]  
Brookes JA, 1999, JMRI-J MAGN RESON IM, V9, P163, DOI 10.1002/(SICI)1522-2586(199902)9:2<163::AID-JMRI3>3.0.CO
[5]  
2-L
[6]   Artifacts in 3-T MRI: Physical background and reduction strategies [J].
Dietrich, Olaf ;
Reiser, Maximilian F. ;
Schoenberg, Stefan O. .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 65 (01) :29-35
[7]   Non-invasive methods of assessing angiogenesis and their value in predicting response to treatment in colorectal cancer [J].
George, ML ;
Dzik-Jurasz, ASK ;
Padhani, AR ;
Brown, G ;
Tait, DM ;
Eccles, SA ;
Swift, RI .
BRITISH JOURNAL OF SURGERY, 2001, 88 (12) :1628-1636
[8]   Assessing changes in tumour vascular function using dynamic contrast-enhanced magnetic resonance imaging [J].
Hayes, C ;
Padhani, AR ;
Leach, MO .
NMR IN BIOMEDICINE, 2002, 15 (02) :154-163
[9]   Temporal sampling requirements for the tracer kinetics modeling of breast disease [J].
Henderson, E ;
Rutt, BK ;
Lee, TY .
MAGNETIC RESONANCE IMAGING, 1998, 16 (09) :1057-1073
[10]   International investigation of breast MRI:: results of a multicentre study (11 sites) concerning diagnostic parameters for contrast-enhanced MRI based on 519 histopathologically correlated lesions [J].
Heywang-Körunner, SH ;
Bick, U ;
Bradley, WG ;
Boné, B ;
Casselman, J ;
Coulthard, A ;
Fischer, U ;
Müller-Schimpfle, M ;
Oellinger, H ;
Patt, R ;
Teubner, J ;
Friedrich, M ;
Newstead, G ;
Holland, R ;
Schauer, A ;
Sickles, EA ;
Tabar, L ;
Waisman, J ;
Wernecke, KD .
EUROPEAN RADIOLOGY, 2001, 11 (04) :531-546