Background: The increasing use of dual-energy computed tomography (CT) and of reduced kVp protocols exposes the marked energy dependence of the Hounsfield unit (HU) as a measure of X-ray attenuation. This dependence of HU on energy limits its use as a quantitative diagnostic parameter, potentially leading to inaccurate diagnoses. Purpose: To describe a method for annotating the HU using superscripts and subscripts that inform the observer of the origin of the unit. Methods: First, we review the HU and describe its use and limitations with variable energy CT. Examples of energy dependence and measureable curve effects are then discussed. The significance of HU value variation and its effects on diagnostic criteria will be presented. Improved annotation based on superscript and subscript methods that are derived from international nomenclature guidelines is proposed. Conclusion: The increasing use of variable energy CT allows for improved diagnostic techniques, and reduced radiation exposure, but at the expense of increasing the complexity of interpreting the meaning of HU values in various diagnostic contexts. A method for precise HU description is presented, streamlining diagnostic criteria.
引用
收藏
页码:766 / 771
页数:6
相关论文
共 8 条
[1]  
[Anonymous], 2008, National Institute of Standards and Technology
[2]   Dual-Energy Computed Tomographic Scanners: Principles, Comparisons, and Contrasts [J].
Bolus, David N. .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (06) :944-947
[3]   COMPUTERIZED TRANSVERSE AXIAL SCANNING (TOMOGRAPHY) .1. DESCRIPTION OF SYSTEM [J].
HOUNDFIELD, GN .
BRITISH JOURNAL OF RADIOLOGY, 1973, 46 (552) :1016-1022
[4]   COMPUTED MEDICAL IMAGING [J].
HOUNSFIELD, GN .
MEDICAL PHYSICS, 1980, 7 (04) :283-290
[5]  
Hubbell J. H., 2004, X-Ray Mass Attenuation Coefficients, V126, DOI [10.18434/T4D01F, DOI 10.18434/T4D01F]
[6]   CT Hounsfield Numbers of Soft Tissues on Unenhanced Abdominal CT Scans: Variability Between Two Different Manufacturers' MDCT Scanners [J].
Lamba, Ramit ;
McGahan, John P. ;
Corwin, Michael T. ;
Li, Chin-Shang ;
Tran, Tien ;
Seibert, J. Anthony ;
Boone, John M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (05) :1013-1020
[7]   THE UNRELIABILITY OF CT-NUMBERS AS ABSOLUTE VALUES [J].
LEVI, C ;
GRAY, JE ;
MCCULLOUGH, EC ;
HATTERY, RR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 139 (03) :443-447
[8]   White Paper of the Society of Computed Body Tomography and Magnetic Resonance on Dual-Energy CT, Part 1: Technology and Terminology [J].
Siegel, Marilyn J. ;
Kaza, Ravi K. ;
Bolus, David N. ;
Boll, Daniel T. ;
Rofsky, Neil M. ;
De Cecco, Carlo N. ;
Foley, W. Dennis ;
Morgan, Desiree E. ;
Schoepf, U. Joseph ;
Sahani, Dushyant V. ;
Shuman, William P. ;
Vrtiska, Terri J. ;
Yeh, Benjamin M. ;
Berland, Lincoln L. .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (06) :841-845