Indentation modulus and hardness of whisker-reinforced heat-cured dental resin composites

被引:46
作者
Xu, HHK [1 ]
Smith, DT
Schumacher, G
Eichmiller, FC
Antonucci, JM
机构
[1] Natl Inst Stand & Technol, Amer Dent Assoc Hlth Fdn, Paffenbarger Res Ctr, Gaithersburg, MD 20899 USA
[2] Natl Inst Stand & Technol, Div Ceram, Gaithersburg, MD 20899 USA
[3] Natl Inst Stand & Technol, Div Polymer, Gaithersburg, MD 20899 USA
关键词
ceramic whisker; heat cure; resin composite; filler level; indentation; elastic modulus; brittleness; fracture toughness;
D O I
10.1016/S0109-5641(00)00014-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Recent studies showed that ceramic whisker reinforcement imparted a two-fold increase in the strength of dental composites. The aim of this study was to investigate the indentation response and measure the elastic modulus, hardness, and brittleness of whisker-reinforced heat-cured resin composites as a function of filler level, heat-cure temperature, and heat-cure duration. Methods: Silica particles were fused onto silicon nitride whiskers to facilitate silanization and to roughen the whiskers for improved retention in matrix. Whisker filler mass fractions of 0, 20, 40, 60, 70, 74 and 79% were tested. Heat-cure temperature ranged from 100 to 180 degrees C, and duration from 10 min to 24 h. A nano-indentation system enabled the measurement of elastic modulus. Fracture toughness was measured and composite brittleness index was calculated. An inlay/onlay composite and a prosthetic composite were tested as controls. Results: Whisker filler level and heat-cure duration had significant effects on composite properties, while heat-cure temperature had nonsignificant effects. The whisker composite with 79% filler level had a modulus in GPa (mean (SD); n = 6) of 26.9 (1.0), significantly higher than 15.1 (0.2) of an inlay/onlay control, and 16.1 (0.3) of a prosthetic control (Tukey's multiple comparison test; family confidence coefficient = 0.95). The fracture toughness in MPa.m(1/2) was 2.22 (0.26) for the whisker composite, higher than 0.95 (0.11) for inlay/onlay control, and (1.13 +/- 0.19) for prosthetic control. The brittleness index was (0.49 +/- 0.07) for whisker composite, lower than (1.02 +/- 0.12) for inlay/onlay control and (0.63 +/- 0.13) for prosthetic control. Significance: Whisker filler level had a profound influence, heat-cure duration had significant effects, while temperature did not have significant effects, on the properties of whisker composite. The whisker composite had significantly higher elastic modulus and fracture toughness, and lower brittleness than the inlay/onlay and prosthetic controls. Published by Elsevier Science Ltd.
引用
收藏
页码:248 / 254
页数:7
相关论文
共 39 条
[1]  
[Anonymous], E39983 ASTM
[2]   INFLUENCE OF COLORANTS ON CRYSTALLIZATION AND MECHANICAL-PROPERTIES OF LITHIA-BASED GLASS-CERAMICS [J].
ANUSAVICE, KJ ;
ZHANG, NZ ;
MOORHEAD, JE .
DENTAL MATERIALS, 1994, 10 (02) :141-146
[3]  
ASMUSSEN E, 1990, SCAND J DENT RES, V98, P564
[4]   A characterization of first-generation flowable composites [J].
Bayne, SC ;
Thompson, JY ;
Swift, EJ ;
Stamatiades, P ;
Wilkerson, M .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1998, 129 (05) :567-577
[6]   MECHANICAL-PROPERTIES AND FILLER FRACTION OF DENTAL COMPOSITES [J].
BRAEM, M ;
FINGER, W ;
VANDOREN, VE ;
LAMBRECHTS, P ;
VANHERLE, G .
DENTAL MATERIALS, 1989, 5 (05) :346-349
[7]   In vitro wear of composite with varied cure, filler level, and filler treatment [J].
Condon, JR ;
Ferracane, JL .
JOURNAL OF DENTAL RESEARCH, 1997, 76 (07) :1405-1411
[8]   THE RELATIONSHIP BETWEEN FILLER LOADING AND PARTICLE-SIZE DISTRIBUTION IN COMPOSITE RESIN TECHNOLOGY [J].
CROSS, M ;
DOUGLAS, WH ;
FIELDS, RP .
JOURNAL OF DENTAL RESEARCH, 1983, 62 (07) :850-852
[9]  
Eick JD, 1979, ACAD DENT MAT T, V10, P89
[10]   Creep and visco-elastic recovery of cured and secondary-cured composites and resin-modified glass-ionomers [J].
El Hejazi, AA ;
Watts, DC .