Proton minibeam radiation therapy: Experimental dosimetry evaluation

被引:73
作者
Peucelle, C. [1 ,2 ,3 ]
Nauraye, C. [4 ]
Patriarca, A. [4 ]
Hierso, E. [4 ]
Fournier-Bidoz, N. [4 ]
Martinez-Rovira, I. [1 ,2 ,3 ]
Prezado, Y. [1 ,2 ,3 ]
机构
[1] CNRS, UMR 8165, IMNC, F-91406 Orsay, France
[2] Univ Paris 07, F-91406 Orsay, France
[3] Univ Paris 11, F-91406 Orsay, France
[4] Inst Curie, Ctr Protontherapie Orsay, F-91898 Orsay, France
关键词
proton therapy; minibeams; spatial fractionation of the dose; small field dosimetry; FORTHCOMING CLINICAL-TRIALS; RADIOCHROMIC FILM DOSIMETRY; GLIOMA-BEARING RATS; CALCULATION ENGINE; MICROPLANAR BEAMS; BRAIN; RADIOTHERAPY; PHOTON;
D O I
10.1118/1.4935868
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Proton minibeam radiation therapy (pMBRT) is a new radiotherapy (RT) approach that allies the inherent physical advantages of protons with the normal tissue preservation observed when irradiated with submillimetric spatially fractionated beams. This dosimetry work aims at demonstrating the feasibility of the technical implementation of pMBRT. This has been performed at the Institut Curie - Proton Therapy Center in Orsay. Methods: Proton minibeams (400 and 700 mu m-width) were generated by means of a brass multislit collimator. Center-to-center distances between consecutive beams of 3200 and 3500 mu m, respectively, were employed. The (passive scattered) beam energy was 100 MeV corresponding to a range of 7.7 cm water equivalent. Absolute dosimetry was performed with a thimble ionization chamber (IBA CC13) in a water tank. Relative dosimetry was carried out irradiating radiochromic films interspersed in a IBA RW3 slab phantom. Depth dose curves and lateral profiles at different depths were evaluated. Peak-to-valley dose ratios (PVDR), beam widths, and output factors were also assessed as a function of depth. Results: A pattern of peaks and valleys was maintained in the transverse direction with PVDR values decreasing as a function of depth until 6.7 cm. From that depth, the transverse dose profiles became homogeneous due to multiple Coulomb scattering. Peak-to-valley dose ratio values extended from 8.2 +/- 0.5 at the phantom surface to 1.08 +/- 0.06 at the Bragg peak. This was the first time that dosimetry in such small proton field sizes was performed. Despite the challenge, a complete set of dosimetric data needed to guide the first biological experiments was achieved. Conclusions: pMBRT is a novel strategy in order to reduce the side effects of RT. This works provides the experimental proof of concept of this new RT method: clinical proton beams might allow depositing a (high) uniform dose in a brain tumor located in the center of the brain (7.5 cm depth, the worst scenario), while a spatial fractionation of the dose is retained in the normal tissues in the beam path, potentially leading to a gain in tissue sparing. This is the first complete experimental implementation of this promising technique. Biological experiments are needed in order to confirm the clinical potential of pMBRT. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:7108 / 7113
页数:6
相关论文
共 28 条
[1]   Effects of pulsed, spatially fractionated, microscopic synchrotron X-ray beams on normal and tumoral brain tissue [J].
Braeuer-Krisch, E. ;
Serduc, R. ;
Siegbahn, E. A. ;
Le Duc, G. ;
Prezado, Y. ;
Bravin, A. ;
Blattmann, H. ;
Laissue, J. A. .
MUTATION RESEARCH-REVIEWS IN MUTATION RESEARCH, 2010, 704 (1-3) :160-166
[2]   TIME-RELATED AND DOSE-RELATED CHANGES IN THE WHITE MATTER OF THE RAT-BRAIN AFTER SINGLE DOSES OF X-RAYS [J].
CALVO, W ;
HOPEWELL, JW ;
REINHOLD, HS ;
YEUNG, TK .
BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (731) :1043-1052
[3]  
Curtis H J, 1967, Radiat Res Suppl, V7, P250, DOI 10.2307/3583718
[4]   Monochromatic Minibeams Radiotherapy: From Healthy Tissue-Sparing Effect Studies Toward First Experimental Glioma Bearing Rats Therapy [J].
Deman, Pierre ;
Vautrin, Mathias ;
Edouard, Magali ;
Stupar, Vasile ;
Bobyk, Laure ;
Farion, Regine ;
Elleaume, Helene ;
Remy, Chantal ;
Barbier, Emmanuel L. ;
Esteve, Francois ;
Adam, Jean-Francois .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (04) :E693-E700
[5]   Precise radiochromic film dosimetry using a flat-bed document scanner [J].
Devic, S ;
Seuntjens, J ;
Sham, E ;
Podgorsak, EB ;
Schmidtlein, CR ;
Kirov, AS ;
Soares, CG .
MEDICAL PHYSICS, 2005, 32 (07) :2245-2253
[6]   Minibeam Therapy With Protons and Light Ions: Physical Feasibility and Potential to Reduce Radiation Side Effects and to Facilitate Hypofractionation [J].
Dilmanian, F. Avraham ;
Eley, John G. ;
Krishnan, Sunil .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 92 (02) :469-474
[7]   Interlaced x-ray microplanar beams: A radiosurgery approach with clinical potential [J].
Dilmanian, FA ;
Zhong, Z ;
Bacarian, T ;
Benveniste, H ;
Romanelli, P ;
Wang, RL ;
Welwart, J ;
Yuasa, T ;
Rosen, EM ;
Anschel, DJ .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (25) :9709-9714
[8]  
Dilmanian FA, 2002, NEURO-ONCOLOGY, V4, P26, DOI 10.1093/neuonc/4.1.26
[9]  
International Atomic Energy Agency, 2005, IAEA TECHNICAL REPOR, V398
[10]   LET dependence of GafChromic films and an ion chamber in low-energy proton dosimetry [J].
Kirby, Daniel ;
Green, Stuart ;
Palmans, Hugo ;
Hugtenburg, Richard ;
Wojnecki, Cecile ;
Parker, David .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (02) :417-433