Is cardiac magnetic resonance imaging as accurate as echocardiography in the assessment of aortic valve stenosis?

被引:10
作者
Wong, Sophia [1 ]
Spina, Roberto [2 ]
Toemoe, Sianne [3 ]
Dhital, Kumud [3 ,4 ]
机构
[1] Prince Wales Clin Sch, Sydney, NSW, Australia
[2] St Vincents Hosp, Dept Cardiol, Sydney, NSW 2010, Australia
[3] Univ New S Wales, Fac Med, Sydney, NSW, Australia
[4] St Vincents Hosp, Dept Cardiothorac Surg, Sydney, NSW 2010, Australia
关键词
Aortic stenosis; Aortic valve; Valvular disease; Cardiac magnetic resonance imaging; Transthoracic echocardiography; Transoesophageal echocardiography; DOPPLER-ECHOCARDIOGRAPHY; COMPUTED-TOMOGRAPHY; STROKE VOLUME; LOW-GRADIENT; AREA; IMPLANTATION; PLANIMETRY; ROOT;
D O I
10.1093/icvts/ivv362
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A best evidence topic was written according to a structured protocol. The question addressed was: is cardiac magnetic resonance (CMR) imaging as accurate as echocardiography in the assessment of aortic valve stenosis? Altogether 239 papers were found using the reported search. Only 12 demonstrated the best evidence to answer the clinical question. Nine of these 12 papers found CMR to correlate well with transthoracic echocardiography (TTE) or transoesophageal echocardiography (TOE) in the evaluation of aortic valve stenosis. When aortic valve areas were measured with cardiac tomography (CT) or cardiac catheterization (CC), four papers found CMR to be more accurate than TTE. Eight of 12 papers found CMR to have excellent reliability and reproducibility, as demonstrated by the low inter- and intraobserver variability. Four papers did not estimate intra- or interobserver variability. One paper noted a sensitivity and specificity of 96 and 100%, respectively, when using CMR to detect severe aortic stenosis (AS) that had been diagnosed during CC. A second paper noted a lower sensitivity and specificity of 78 and 89%, respectively, but this was still better than the sensitivities and specificities found when using TOE or TTE to detect severe AS, as noted on CC. We conclude that current evidence finds echocardiography and CMR to be equally reliable in assessing aortic stenosis. CMR has better inter- and intraobserver reliability and demonstrates an advantage over echocardiography in the detection of severe AS with greater specificity and sensitivity. The final choice, however, is as likely to be influenced by the availability of magnetic resonance imaging and expertise in interpreting the results as by accuracy and reliability.
引用
收藏
页码:480 / 486
页数:7
相关论文
共 13 条
[1]   Aortic Valve Area, Stroke Volume, Left Ventricular Hypertrophy, Remodeling, and Fibrosis in Aortic Stenosis Assessed by Cardiac Magnetic Resonance Imaging Comparison Between High and Low Gradient and Normal and Low Flow Aortic Stenosis [J].
Barone-Rochette, Gilles ;
Pierard, Sophie ;
Seldrum, Stephanie ;
de Ravenstein, Christophe de Meester ;
Melchior, Julie ;
Maes, Frederic ;
Pouleur, Anne-Catherine ;
Vancraeynest, David ;
Pasquet, Agnes ;
Vanoverschelde, Jean-Louis ;
Gerber, Bernhard L. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2013, 6 (06) :1009-1017
[2]   Practical value of cardiac magnetic resonance imaging for clinical quantification of aortic valve stenosis comparison with echocardiography [J].
Caruthers, SD ;
Lin, SJ ;
Brown, P ;
Watkins, MP ;
Williams, TA ;
Lehr, KA ;
Wickline, SA .
CIRCULATION, 2003, 108 (18) :2236-2243
[3]   Echocardiography Underestimates Stroke Volume and Aortic Valve Area: Implications for Patients With Small-Area Low-Gradient Aortic Stenosis [J].
Chin, Calvin W. L. ;
Khaw, Hwan J. ;
Luo, Elton ;
Tan, Shuwei ;
White, Audrey C. ;
Newby, David E. ;
Dweck, Marc R. .
CANADIAN JOURNAL OF CARDIOLOGY, 2014, 30 (09) :1064-1072
[4]   Planimetry of aortic valve area in aortic stenosis by magnetic resonance imaging [J].
Debl, K ;
Djavidani, B ;
Seitz, J ;
Nitz, WF ;
Schmid, FX ;
Muders, F ;
Buchner, S ;
Feuerbach, S ;
Riegger, G ;
Luchner, A .
INVESTIGATIVE RADIOLOGY, 2005, 40 (10) :631-636
[5]   Evaluation of Aortic Valve Stenosis Using Cardiovascular Magnetic Resonance Comparison of an Original Semiautomated Analysis of Phase-Contrast Cardiovascular Magnetic Resonance With Doppler Echocardiography [J].
Defrance, Carine ;
Bollache, Emilie ;
Kachenoura, Nadjia ;
Perdrix, Ludivine ;
Hrynchyshyn, Nataliya ;
Bruguiere, Eric ;
Redheuil, Alban ;
Diebold, Benoit ;
Mousseaux, Elie .
CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (05) :604-612
[6]  
DUNNING J, 2003, INTERACTIVE CARDIOVA, P405
[7]   Comparison between cardiovascular magnetic resonance and transthoracic doppler echocardiography for the estimation of effective orifice area in aortic stenosis [J].
Garcia, Julio ;
Kadem, Lyes ;
Larose, Eric ;
Clavel, Marie-Annick ;
Pibarot, Philippe .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2011, 13
[8]   Multimodality Imaging in Transcatheter Aortic Valve Implantation and Post-Procedural Aortic Regurgitation Comparison Among Cardiovascular Magnetic Resonance, Cardiac Computed Tomography, and Echocardiography [J].
Jabbour, Andrew ;
Ismail, Tevfik F. ;
Moat, Neil ;
Gulati, Ankur ;
Roussin, Isabelle ;
Alpendurada, Francisco ;
Park, Bradley ;
Okoroafor, Francois ;
Asgar, Anita ;
Barker, Sarah ;
Davies, Simon ;
Prasad, Sanjay K. ;
Rubens, Michael ;
Mohiaddin, Raad H. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (21) :2165-2173
[9]   Evaluation of aortic stenosis by cardiovascular magnetic resonance imaging: comparison with established routine clinical techniques [J].
Kupfahl, C ;
Honold, M ;
Meinhardt, G ;
Vogelsberg, H ;
Wagner, A ;
Mahrholdt, H ;
Sechtem, U .
HEART, 2004, 90 (08) :893-901
[10]   Comparison of Magnetic Resonance Imaging of Aortic Valve Stenosis and Aortic Root to Multimodality Imaging for Selection of Transcatheter Aortic Valve Implantation Candidates [J].
Paelinck, Bernard P. ;
Van Herck, Paul L. ;
Rodrigus, Inez ;
Claeys, Marc J. ;
Laborde, Jean-Claude ;
Parizel, Paul M. ;
Vrints, Christiaan J. ;
Bosmans, Johan M. .
AMERICAN JOURNAL OF CARDIOLOGY, 2011, 108 (01) :92-98