Accuracy of GDx variable corneal compensation polarization measurements in normal human eyes: effect of accommodation, cycloplegia, focus, pupil size, and eye selection on reproducibility

被引:4
作者
Levy, N. S. [1 ]
Schachar, I. H. [1 ]
机构
[1] Florida Ophthalm Inst, Gainesville, FL 32605 USA
关键词
scanning laser polarimetry; pupil size; focus; accommodation; cycloplegia; GDx VCC;
D O I
10.1038/sj.eye.6702187
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To evaluate the reproducibility of variable corneal compensation (VCC) and the effect of accommodation, cycloplegia, eye selection, focus, and pupil size on this measurement of polarization. Methods Using a GDx scanning laser polarimeter, multiple measurements of the VCC were obtained from each eye of 33 healthy, young adults under differing conditions. Pupil size and refraction were independently measured with a pupillometer and an autorefractometer. The effects of eye, instrument focus, pupil diameter, cycloplegia, and accommodation were statistically assessed. Results The reproducibility of a single retardation measurement and its axis, as determined by the standard deviations (SD) of repeated measurements, is +/- 1.58nm and 2.10 degrees, respectively. There is a difference in retardation between right and left eyes, of 5.26 +/- 9 nm, P = 0.002. Increasing pupil size increases retardation. Cycloplegia or defocusing decreases retardation, and pharmacologically induced accommodation has no effect on retardation. Conclusions The retardation and its axis are highly reproducible measurements when the pupil is of physiologic size and the GDx is properly focused. There is a consistent difference in VCC retardation between the paired right and left eyes. This difference may reflect equipment-induced measurement artefact and/or an anatomic asymmetry between the paired eyes of the subjects studied. Clinicians should be cautious when comparing interocular VCC measurements between paired right and left eyes and using data pooled from both eyes for age-adjusted, normalized standards.
引用
收藏
页码:333 / 340
页数:8
相关论文
共 24 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
BLUMENTHAL EZ, INVEST OPHTHALMOL VI
[3]   Effect of individualized compensation for anterior segment birefringence on retinal nerve fiber layer assessments as determined by scanning laser polarimetry [J].
Choplin, NT ;
Zhou, QY ;
Knighton, RW .
OPHTHALMOLOGY, 2003, 110 (04) :719-725
[4]   SPATIALLY RESOLVED BIREFRINGENCE OF THE RETINAL NERVE-FIBER LAYER ASSESSED WITH A RETINAL LASER ELLIPSOMETER [J].
DREHER, AW ;
REITER, K ;
WEINREB, RN .
APPLIED OPTICS, 1992, 31 (19) :3730-3735
[5]  
ENOCH JM, 1972, INVEST OPHTH VISUAL, V11, P1017
[6]   Operator learning effect and interoperator reproducibility of the scanning laser polarimeter with variable corneal compensation [J].
Frenkel, S ;
Slonim, E ;
Horani, A ;
Molcho, M ;
Barzel, I ;
Blumenthal, EZ .
OPHTHALMOLOGY, 2005, 112 (02) :257-261
[7]   Eccentricity and measurement variability and repeatability with the retinal thickness analyser [J].
Gilmore, ED ;
Hudson, C .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (01) :62-65
[8]   Correction for corneal polarization axis improves the discriminating power of scanning laser polarimetry [J].
Greenfield, DS ;
Knighton, RW ;
Feuer, WJ ;
Schiffman, JC ;
Zangwill, L ;
Weinreb, RN .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 134 (01) :27-33
[9]  
Hoh ST, 1999, J GLAUCOMA, V8, P159
[10]  
KIRKWOOD BR, 2003, ESSENTIAL MED STAT, P74