A confirmatory analysis of malachite green residues in rainbow trout with liquid chromatography-electrospray tandem mass spectrometry

被引:63
作者
Halme, Kirsi [1 ]
Lindfors, Erja [1 ]
Peltonen, Kimmo [1 ]
机构
[1] Finnish Food Safety Author Evira, Chem & Toxicol Res Unit, FI-00790 Helsinki, Finland
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2007年 / 845卷 / 01期
关键词
malachite green; leucomalachite green; fish; LC-MS/MS; confirmation;
D O I
10.1016/j.jchromb.2006.07.048
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A quantitative liquid chromatography-tandem mass spectrometric (LC-MS/MS) method has been developed for the determination of malachite green (MG) and its metabolite leucomalachite green (LMG) in fish. Residues were extracted with an acetonitrile-acetate buffer and purified using the automated solid-phase extraction (ASPEC). Residues were analyzed with a reversed-phase LC-MS/MS using a positive-ion electrospray ionisation (ESI). Isotope-labelled leucomalachite green (LMG-D5) was used as an internal standard for the quantification of LMG residues. The related dye, brilliant green (BG) was used as an instrumental standard. Identification and quantification of analytes were based on the ion transitions monitored by multiple reaction monitoring (MRM). The decision limit (CC alpha) for MG and LMG was 0.13 and 0.16 mu g kg(-1). The respective detection capabilities (CC beta) were 0.22 and 0.27 mu g kg(-1). The absolute recovery (repeatability SDr) was in the range of 58-65% (7.8-11.2%) for MG and 59-68% (9.7-16.9%) for LMG. LMG was quantified also based on the internal standard, giving a recovery (repeatability SDr) of 103-110% (4.8-9.3%). The method was further evaluated by analyzing a total of 34 fish residue monitoring samples, of which eight samples were found to be non-compliant containing low residues of LMG. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:74 / 79
页数:6
相关论文
共 23 条
[1]   MALACHITE GREEN - A REVIEW [J].
ALDERMAN, DJ .
JOURNAL OF FISH DISEASES, 1985, 8 (03) :289-298
[2]   POSTCOLUMN REACTION FOR SIMULTANEOUS ANALYSIS OF CHROMATIC AND LEUCO FORMS OF MALACHITE GREEN AND CRYSTAL VIOLET BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PHOTOMETRIC DETECTION [J].
ALLEN, JL ;
MEINERTZ, JR .
JOURNAL OF CHROMATOGRAPHY, 1991, 536 (1-2) :217-222
[3]  
ALLEN JL, 1994, J AOAC INT, V77, P553
[4]  
BAUER K, 1988, ARCH LEBENSMITTELHYG, V39, P97
[5]   Determination of residues of malachite green in aquatic animals [J].
Bergwerff, AA ;
Scherpenisse, P .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 788 (02) :351-359
[6]  
Culp SJ, 1996, J AM COLL TOXICOL, V15, P219, DOI 10.3109/10915819609008715
[7]  
Doerge DR, 1998, RAPID COMMUN MASS SP, V12, P1625, DOI 10.1002/(SICI)1097-0231(19981115)12:21<1625::AID-RCM373>3.0.CO
[8]  
2-I
[9]  
*EUR COMM, SANCO34002005 EUR CO
[10]   SIMULTANEOUS DETERMINATION OF MALACHITE GREEN AND ITS METABOLITE LEUCOMALACHITE GREEN IN EEL PLASMA USING POSTCOLUMN OXIDATION [J].
HAJEE, CAJ ;
HAAGSMA, N .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1995, 669 (02) :219-227