Process sampling module coupled with purge and trap-GC-FID for in situ auto-monitoring of volatile organic compounds in wastewater

被引:22
作者
Liu, Hsin-Wang [2 ]
Liu, Yung-Tsun [2 ]
Wu, Bei-Zen [2 ]
Nian, Hung-Chi [2 ]
Chen, Hsing-Jung [3 ]
Chiu, Kong-Hwa [1 ]
Lo, Jiunn-Guang [2 ]
机构
[1] Natl DongHwa Univ, Dept Appl Sci, Hualien 970, Taiwan
[2] Natl Tsing Hua Univ, Dept Biomed Engn & Environm Sci, Hsinchu 310, Taiwan
[3] Natl Tsing Hua Univ, Dept Chem, Taichung 402, Taiwan
关键词
Process sampling module; P&T-GC-FID; In situ auto-monitoring; VOCs; Water; SOLID-PHASE MICROEXTRACTION; CHROMATOGRAPHY-MASS SPECTROMETRY; GAS-CHROMATOGRAPHY; SURFACE WATERS; HEADSPACE; TRIHALOMETHANES; EXTRACTION; SYSTEM; LEVEL; AIR;
D O I
10.1016/j.talanta.2009.08.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automatic sampling device, i.e., process sampling module (PSM), connected with a purge and trap-GC-FID system has been developed for real-time monitoring of VOCs in wastewater. The system was designed to simultaneously monitor 17 compounds, including one polar compound, i.e., acetone, and 16 non-polar compounds. The trapping tube is packed with two adsorbents, Carbopack B and Carbosieve III, to trap target compounds. For the purpose of in situ monitoring, the flush valve of the sampling tube is composed of two two-way valves and a time controller to prevent absorption interference of the residue. The optimal conditions for the analytical system include a 12 min purge time at a temperature of 60 degrees C, and 4 min of desorption time with a desorption temperature of 260 degrees C. Good chromatograms have been obtained with the analytical system even if a cryogenic device and de-misting were not used. The relative standards deviation (RSD) of the system is between 2% and 13.4%, and accuracies between 0.3 and 23.5% have been achieved. The detection limits of the method range from 0.32 to 2.39 ppb. In this system, the four parts, i.e., PSM, P&T, GC. and FID, were simple, reliable and rugged. Also, the interface of these four parts was simple and dependable. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:903 / 908
页数:6
相关论文
共 31 条
[21]   A tentative characterization of white dry-cured hams from Teruel (Spain) by SPME-GC [J].
Luna, G ;
Aparicio, R ;
García-González, DL .
FOOD CHEMISTRY, 2006, 97 (04) :621-630
[22]   Automated analysis of 2-methyl-3-furanthiol and 3-mercaptohexyl acetate at ng L-1 level by headspace solid-phase microextracion with on-fibre derivatisation and gas chromatography-negative chemical ionization mass spectrometric determination [J].
Mateo-Vivaracho, Laura ;
Ferreira, Vicente ;
Cacho, Juan .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1121 (01) :1-9
[23]   Headspace membrane introduction mass spectrometry for trace level analysis of VOCs in soil and other solid matrixes [J].
Mendes, MA ;
Sparrapan, R ;
Eberlin, MN .
ANALYTICAL CHEMISTRY, 2000, 72 (09) :2166-2170
[24]  
MILENA P, 2003, J CHROMATOGR A, V985, P117
[25]   Determination of volatile organic compounds in surface waters and treated wastewater in Greece [J].
Nikolaou, AD ;
Golfinopoulos, G ;
Kostopoulou, MN ;
Kolokythas, GA ;
Lekkas, TD .
WATER RESEARCH, 2002, 36 (11) :2883-2890
[26]   Gas chromatography-mass spectrometry with headspace for the analysis of volatile organic compounds in waste water [J].
Safarova, VI ;
Sapelnikova, SV ;
Djazhenko, EV ;
Teplova, GI ;
Shajdulina, GF ;
Kudasheva, FK .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 800 (1-2) :325-330
[27]   Measurement of trihalomethanes in potable and recreational waters using solid phase micro extraction with gas chromatography-mass spectrometry [J].
Stack, MA ;
Fitzgerald, G ;
O'Connell, S ;
James, KJ .
CHEMOSPHERE, 2000, 41 (11) :1821-1826
[28]   QUANTITATIVE-DETERMINATION OF ACRYLONITRILE IN AN INDUSTRIAL EFFLUENT BY AMBIENT-TEMPERATURE PURGE AND TRAP CAPILLARY GC MS AND BY HEATED PURGE AND TRAP GC FID [J].
VASSILAROS, DL ;
BZIK, TJ ;
CARA, CA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1991, 25 (05) :878-883
[29]   Comparison of two field sampling procedures (en core and field methanol extraction) for volatile organic compounds [J].
Vega, AM ;
Lancaster, VA ;
Roulier, MH .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (24) :6790-6794
[30]   Construction and validation of automated purge-and-trap-gas chromatography for the determination of volatile organic compounds [J].
Wang, JL ;
Chen, WL .
JOURNAL OF CHROMATOGRAPHY A, 2001, 927 (1-2) :143-154