Process sampling module coupled with purge and trap-GC-FID for in situ auto-monitoring of volatile organic compounds in wastewater

被引:22
作者
Liu, Hsin-Wang [2 ]
Liu, Yung-Tsun [2 ]
Wu, Bei-Zen [2 ]
Nian, Hung-Chi [2 ]
Chen, Hsing-Jung [3 ]
Chiu, Kong-Hwa [1 ]
Lo, Jiunn-Guang [2 ]
机构
[1] Natl DongHwa Univ, Dept Appl Sci, Hualien 970, Taiwan
[2] Natl Tsing Hua Univ, Dept Biomed Engn & Environm Sci, Hsinchu 310, Taiwan
[3] Natl Tsing Hua Univ, Dept Chem, Taichung 402, Taiwan
关键词
Process sampling module; P&T-GC-FID; In situ auto-monitoring; VOCs; Water; SOLID-PHASE MICROEXTRACTION; CHROMATOGRAPHY-MASS SPECTROMETRY; GAS-CHROMATOGRAPHY; SURFACE WATERS; HEADSPACE; TRIHALOMETHANES; EXTRACTION; SYSTEM; LEVEL; AIR;
D O I
10.1016/j.talanta.2009.08.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automatic sampling device, i.e., process sampling module (PSM), connected with a purge and trap-GC-FID system has been developed for real-time monitoring of VOCs in wastewater. The system was designed to simultaneously monitor 17 compounds, including one polar compound, i.e., acetone, and 16 non-polar compounds. The trapping tube is packed with two adsorbents, Carbopack B and Carbosieve III, to trap target compounds. For the purpose of in situ monitoring, the flush valve of the sampling tube is composed of two two-way valves and a time controller to prevent absorption interference of the residue. The optimal conditions for the analytical system include a 12 min purge time at a temperature of 60 degrees C, and 4 min of desorption time with a desorption temperature of 260 degrees C. Good chromatograms have been obtained with the analytical system even if a cryogenic device and de-misting were not used. The relative standards deviation (RSD) of the system is between 2% and 13.4%, and accuracies between 0.3 and 23.5% have been achieved. The detection limits of the method range from 0.32 to 2.39 ppb. In this system, the four parts, i.e., PSM, P&T, GC. and FID, were simple, reliable and rugged. Also, the interface of these four parts was simple and dependable. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:903 / 908
页数:6
相关论文
共 31 条
  • [1] Determination of trihalomethanes in chlorinated sea water samples using a purge-and-trap system coupled to gas chromatography
    Allonier, AS
    Khalanski, M
    Bermond, A
    Camel, V
    [J]. TALANTA, 2000, 51 (03) : 467 - 477
  • [2] [Anonymous], 2004, World Health Organization Guidelines for Drinking Water Quality Third Edition, V1
  • [3] The health effects of nonindustrial indoor air pollution
    Bernstein, Jonathan A.
    Alexis, Neil
    Bacchus, Hyacinth
    Bernstein, I. Leonard
    Fritz, Pat
    Horner, Elliot
    Li, Ning
    Mason, Stephany
    Nel, Andre
    Oullette, John
    Reijula, Kari
    Reponen, Tina
    Seltzer, James
    Smith, Alisa
    Tarlo, Susan M.
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2008, 121 (03) : 585 - 591
  • [4] The properties of chromatomembrane cells in flow systems coupled to gas chromatography - analysis of volatile organic compounds
    Bloch, C
    Simon, J
    Moskvin, LN
    Rodinkov, OV
    [J]. TALANTA, 2000, 52 (01) : 123 - 128
  • [5] On-line monitoring of trihalomethanes in drinking water using continuous-flow purge and cryofocusing gas chromatography-mass spectrometry
    Chen, TC
    Her, GR
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2001, 927 (1-2) : 229 - 235
  • [6] Quality of indoor residential air and health
    Dales, Robert
    Liu, Ling
    Wheeler, Amanda J.
    Gilbert, Nicolas L.
    [J]. CANADIAN MEDICAL ASSOCIATION JOURNAL, 2008, 179 (02) : 147 - 152
  • [7] Multiple headspace solid-phase microextraction for the quantitative determination of volatile organic compounds in multilayer packagings
    Ezquerro, O
    Pons, B
    Tena, MT
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 999 (1-2) : 155 - 164
  • [8] Investigation into the benzene and toluene content of soft drinks
    Fabietti, F
    Delise, M
    Bocca, AP
    [J]. FOOD CONTROL, 2001, 12 (08) : 505 - 509
  • [9] DETERMINATION OF VOLATILE SULFUR-COMPOUNDS IN WATER SAMPLES, BEER AND COFFEE WITH PURGE-AND-TRAP GAS-CHROMATOGRAPHY MICROWAVE-INDUCED PLASMA-ATOMIC EMISSION-SPECTROMETRY
    GERBERSMANN, C
    LOBINSKI, R
    ADAMS, FC
    [J]. ANALYTICA CHIMICA ACTA, 1995, 316 (01) : 93 - 104
  • [10] The preparation, properties and application of carbon fibers for SPME
    Gierak, A.
    Eredych, M.
    Bartnicki, A.
    [J]. TALANTA, 2006, 69 (05) : 1079 - 1087