Multi-modal signal acquisition using a synchronized wireless body sensor network in geriatric patients

被引:9
作者
Pflugradt, Maik [1 ]
Mann, Steffen [1 ]
Tigges, Timo [1 ]
Goernig, Matthias [2 ]
Orglmeister, Reinhold [1 ]
机构
[1] Tech Univ Berlin, Chair Elect & Med Signal Proc, Berlin, Germany
[2] Geriatr Rehabil Klin, Stadt Krankenhaus Dresden Neustadt, Dresden, Germany
来源
BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK | 2016年 / 61卷 / 01期
关键词
bluetooth synchronization; body sensor network; heart rate; homemonitoring; personal healthcare; pulse rate; BLOOD-PRESSURE; CARDIOVASCULAR-DISEASE; WEARABLE SENSORS; CUFF-LESS; SYSTEM; PHOTOPLETHYSMOGRAPHY;
D O I
10.1515/bmt-2014-0178
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wearable home-monitoring devices acquiring various biosignals such as the electrocardiogram, photo-plethysmogram, electromyogram, respirational activity and movements have become popular in many fields of research, medical diagnostics and commercial applications. Especially ambulatory settings introduce still unsolved challenges to the development of sensor hardware and smart signal processing approaches. This work gives a detailed insight into a novel wireless body sensor network and addresses critical aspects such as signal quality, synchronicity among multiple devices as well as the system's overall capabilities and limitations in cardiovascular monitoring. An early sign of typical cardiovascular diseases is often shown by disturbed autonomic regulations such as orthostatic intolerance. In that context, blood pressure measurements play an important role to observe abnormalities like hypo- or hypertensions. Non-invasive and unobtrusive blood pressure monitoring still poses a significant challenge, promoting alternative approaches including pulse wave velocity considerations. In the scope of this work, the presented hardware is applied to demonstrate the continuous extraction of multi modal parameters like pulse arrival time within a preliminary clinical study. A Schellong test to diagnose orthostatic hypotension which is typically based on blood pressure cuff measurements has been conducted, serving as an application that might significantly benefit from novel multi-modal measurement principles. It is further shown that the system's synchronicity is as precise as 30 mu s and that the integrated analog preprocessing circuits and additional accelerometer data provide significant advantages in ambulatory measurement environments.
引用
收藏
页码:57 / 68
页数:12
相关论文
共 74 条
[1]   Wireless sensor networks for healthcare: A survey [J].
Alemdar, Hande ;
Ersoy, Cem .
COMPUTER NETWORKS, 2010, 54 (15) :2688-2710
[2]   Photoplethysmography and its application in clinical physiological measurement [J].
Allen, John .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :R1-R39
[3]  
[Anonymous], 2013, INT C WEAR IMPL BOD, DOI DOI 10.1109/BSN.2013.6575466
[4]  
Bluetooth Special Interest Group, 2013, BLUET COR SPEC COR V
[5]   Non-invasive pulsatile arterial pressure and stroke volume changes from the human finger [J].
Bogert, LWJ ;
van Lieshout, JJ .
EXPERIMENTAL PHYSIOLOGY, 2005, 90 (04) :437-446
[6]  
Bustamante J., 2013, 2013 PAN AM HLTH CAR
[7]   A novel Body Sensor Network for Parkinson's disease patients rehabilitation assessment [J].
Caldara, M. ;
Comotti, D. ;
Galizzi, M. ;
Locatelli, P. ;
Re, V. ;
Alimonti, D. ;
Poloni, M. ;
Rizzetti, M. C. .
2014 11TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2014, :81-86
[8]  
Casamassima F., 2013, P 2013 INT C BOD SEN, P1
[9]  
Casas R, 2005, PROCEEDINGS OF THE THIRD INTERNATIONAL WORKSHOP ON INTELLIGENT SOLUTIONS IN EMBEDDED SYSTEMS, P79
[10]  
Cattivelli FS, 2009, SIXTH INTERNATIONAL WORKSHOP ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS, PROCEEDINGS, P114, DOI [10.1109/BSN.2009.35, 10.1109/P3644.34]