Detection of acute ischemia from the EASI-derived 12-lead electrocardiogram and from the 12-lead electrocardiogram acquired in clinical practice

被引:29
作者
Sejersten, Maria
Wagner, Galen S.
Pahlm, Olle
Warren, James W.
Feldman, Charles L.
Horacek, B. Milan [1 ]
机构
[1] Dalhousie Univ, Fac Med, Halifax, NS, Canada
[2] Brigham & Womens Hosp, Div Cardiovasc, Boston, MA 02115 USA
[3] Univ Lund Hosp, Dept Clin Physiol, S-22185 Lund, Sweden
[4] Duke Clin Res Inst, Dept Cardiol, Durham, NC USA
基金
加拿大健康研究院;
关键词
electrocardiogram; FASI leads; Mason-Likar leads; acute ischemia; ACUTE MYOCARDIAL-ISCHEMIA; STANDARD ECG; LEADS; ACCURACY; INFARCTION; DERIVATION; DIAGNOSIS; SYSTEM;
D O I
10.1016/j.jelectrocard.2006.08.099
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ST-segment measurements in the standard 12-lead electrocardiogram (ECG) of patients with acute coronary syndromes are crucial for these patients' management. Our objective was to determine whether the 12-lead ECG derived from the 3-lead EASI system can attain a level of diagnostic performance similar to that of the Mason-Likar (ML) 12-lead ECG acquired in clinical practice (CP) by paramedics and emergency department technicians. Using 120-lead body surface potential maps recorded before and during balloon inflation angioplasty from 88 patients (divided into "responders" and "nonresponders"), and electrode placement data from 60 applications of precordial leads in CP, we generated for the "nonischemic" and "ischemic' states of each patient the following lead sets: the ML 12-lead ECG, the EASI-derived 12-lead ECG, and 60 sets of 12-lead CP ECGs. We extracted ST deviations at J + 60 milliseconds, summed them for all 12 leads of each lead set to obtain Sigma ST, and, by using the bootstrap method, determined the mean sensitivity and specificity for recognizing the "ischemic' state at various thresholds of Sigma ST. Results were displayed as receiver operating characteristics, and the area under these curves (AUC) +/- SE was used as the measure of diagnostic performance. AUC SE for all patients were ML ECG, 0.66 +/- 0.03; EASI ECG, 0.64 +/- 0.03; and CP ECG, 0.67 +/- 0.03. Corresponding results for responders only were 0.81 +/- 0.04 for ML ECG, 0.78 +/- 0.04 for EASI ECG, and 0.81 +/- 0.04 for CP ECG. The differences between the AUCs for the different lead sets were not significant (P >.05). Thus, the EASI-derived 12-lead ECG is as good for detecting acute ischemia as is the 12-lead ECG acquired in CP. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:120 / 126
页数:7
相关论文
共 50 条
[21]   Competency in interpretation of the 12-lead electrocardiogram among Swiss doctors [J].
Goy, Jean-Jacques ;
Schlaepfer, Juerg ;
Stauffer, Jean-Christophe .
SWISS MEDICAL WEEKLY, 2013, 143
[22]   Design of a Wearable 12-Lead Noncontact Electrocardiogram Monitoring System [J].
Hsu, Chien-Chin ;
Lin, Bor-Shing ;
He, Ke-Yi ;
Lin, Bor-Shyh .
SENSORS, 2019, 19 (07)
[23]   CAVIAR - A TOOL TO IMPROVE SERIAL ANALYSIS OF THE 12-LEAD ELECTROCARDIOGRAM [J].
BERG, J ;
FAYN, J ;
EDENBRANDT, L ;
LUNDH, B ;
MALMSTROM, P ;
RUBEL, P .
CLINICAL PHYSIOLOGY, 1995, 15 (05) :435-445
[24]   Coefficients for the Derivation of Posterior and Right Sided Chest Leads From the 12-lead Electrocardiogram [J].
Jennings, Michael R. ;
Rababah, Ali S. ;
Biglarbeigi, Pardis ;
Brisk, Rob ;
Gueldenring, Daniel ;
Bond, Raymond ;
McLaughlin, James ;
Finlay, Dewar D. .
2020 COMPUTING IN CARDIOLOGY, 2020,
[25]   Feasibility of His bundle pacing facilitated by EASI derived 12-lead ECG [J].
Langanke, Alexander ;
Andreas, Klaus .
JOURNAL OF ELECTROCARDIOLOGY, 2023, 81 :272-276
[26]   Derived 12-lead electrocardiogram in the assessment of ST-segment deviation and cardiac rhythm [J].
Chantad, D ;
Krittayaphong, R ;
Komoltri, C .
JOURNAL OF ELECTROCARDIOLOGY, 2006, 39 (01) :7-12
[27]   Remodeling of the 12-lead electrocardiogram in immediate survivors of sudden cardiac arrest [J].
Held, Elizabeth P. ;
Reinier, Kyndaron ;
Uy-Evanado, Audrey ;
Nakamura, Kotoka ;
Chugh, Harpriya S. ;
Jui, Jonathan ;
Chugh, Sumeet S. .
RESUSCITATION, 2020, 153 :169-175
[28]   MULTILABEL 12-LEAD ELECTROCARDIOGRAM CLASSIFICATION USING BEAT TO SEQUENCE AUTOENCODERS [J].
Wong, Alexander William ;
Salimi, Amir ;
Hindle, Abram ;
Kalmady, Sunil Vasu ;
Kaul, Padma .
2021 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP 2021), 2021, :1270-1274
[29]   Prognostic value of 12-lead electrocardiogram during dobutamine stress echocardiography [J].
Dhond, MR ;
Nguyen, T ;
Whitley, TB ;
Donnell, K ;
Bommer, WJ .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2000, 17 (05) :429-432
[30]   A Flexible and Stretchable 12-Lead Electrocardiogram System with Individually Deformable Interconnects [J].
Wan, Chunxue ;
Gao, Shenghan ;
Shang, Xue ;
Wu, Ziyue ;
Li, Tianyu ;
Ling, Wei ;
Zhou, Mingxing ;
Huo, Wenxing ;
Guo, Yu ;
Huang, Xian .
ADVANCED MATERIALS TECHNOLOGIES, 2022, 7 (03)