Detection of acute ischemia from the EASI-derived 12-lead electrocardiogram and from the 12-lead electrocardiogram acquired in clinical practice

被引:28
|
作者
Sejersten, Maria
Wagner, Galen S.
Pahlm, Olle
Warren, James W.
Feldman, Charles L.
Horacek, B. Milan [1 ]
机构
[1] Dalhousie Univ, Fac Med, Halifax, NS, Canada
[2] Brigham & Womens Hosp, Div Cardiovasc, Boston, MA 02115 USA
[3] Univ Lund Hosp, Dept Clin Physiol, S-22185 Lund, Sweden
[4] Duke Clin Res Inst, Dept Cardiol, Durham, NC USA
基金
加拿大健康研究院;
关键词
electrocardiogram; FASI leads; Mason-Likar leads; acute ischemia; ACUTE MYOCARDIAL-ISCHEMIA; STANDARD ECG; LEADS; ACCURACY; INFARCTION; DERIVATION; DIAGNOSIS; SYSTEM;
D O I
10.1016/j.jelectrocard.2006.08.099
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ST-segment measurements in the standard 12-lead electrocardiogram (ECG) of patients with acute coronary syndromes are crucial for these patients' management. Our objective was to determine whether the 12-lead ECG derived from the 3-lead EASI system can attain a level of diagnostic performance similar to that of the Mason-Likar (ML) 12-lead ECG acquired in clinical practice (CP) by paramedics and emergency department technicians. Using 120-lead body surface potential maps recorded before and during balloon inflation angioplasty from 88 patients (divided into "responders" and "nonresponders"), and electrode placement data from 60 applications of precordial leads in CP, we generated for the "nonischemic" and "ischemic' states of each patient the following lead sets: the ML 12-lead ECG, the EASI-derived 12-lead ECG, and 60 sets of 12-lead CP ECGs. We extracted ST deviations at J + 60 milliseconds, summed them for all 12 leads of each lead set to obtain Sigma ST, and, by using the bootstrap method, determined the mean sensitivity and specificity for recognizing the "ischemic' state at various thresholds of Sigma ST. Results were displayed as receiver operating characteristics, and the area under these curves (AUC) +/- SE was used as the measure of diagnostic performance. AUC SE for all patients were ML ECG, 0.66 +/- 0.03; EASI ECG, 0.64 +/- 0.03; and CP ECG, 0.67 +/- 0.03. Corresponding results for responders only were 0.81 +/- 0.04 for ML ECG, 0.78 +/- 0.04 for EASI ECG, and 0.81 +/- 0.04 for CP ECG. The differences between the AUCs for the different lead sets were not significant (P >.05). Thus, the EASI-derived 12-lead ECG is as good for detecting acute ischemia as is the 12-lead ECG acquired in CP. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:120 / 126
页数:7
相关论文
共 50 条
  • [1] Diagnostic conclusions from the EASI-derived 12-lead electrocardiogram as compared with the standard 12-lead electrocardiogram in children
    Welinder, A
    Feild, DQ
    Liebman, J
    Maynard, C
    Wagner, GS
    Wettrell, G
    Pahlm, O
    AMERICAN HEART JOURNAL, 2006, 151 (05) : 1059 - 1064
  • [2] Effects of electrode placement errors in the EASI-derived 12-lead electrocardiogram
    Finlay, Dewar D.
    Nugent, Chris D.
    Nelwan, Stefan P.
    Bond, Raymond R.
    Donnelly, Mark P.
    Guldenring, Daniel
    JOURNAL OF ELECTROCARDIOLOGY, 2010, 43 (06) : 606 - 611
  • [3] Is the EASI 12-lead electrocardiogram comparable to the standard 12-lead electrocardiogram for diagnosing cardiac rhythm and myocardial ischemia?
    Drew, BJ
    Pelter, MM
    Adams, MG
    Wung, SF
    Taylor, CA
    Banks, AS
    CIRCULATION, 1999, 100 (18) : 736 - 736
  • [4] DERIVING THE 12-LEAD ELECTROCARDIOGRAM FROM 4 (EASI) ELECTRODES
    DOWER, GE
    YAKUSH, A
    NAZZAL, SB
    JUTZY, RV
    RUIZ, CE
    JOURNAL OF ELECTROCARDIOLOGY, 1988, 21 : S182 - S187
  • [5] Accuracy of the EASI 12-lead electrocardiogram compared to the standard 12-lead electrocardiogram for diagnosing multiple cardiac abnormalities
    Drew, BJ
    Pelter, MM
    Wung, SF
    Adams, MG
    Taylor, C
    Evans, GT
    Foster, E
    JOURNAL OF ELECTROCARDIOLOGY, 1999, 32 : 38 - 47
  • [6] 12-LEAD ELECTROCARDIOGRAM
    REES, P
    BRITISH MEDICAL JOURNAL, 1968, 1 (5594): : 768 - &
  • [7] Detection of Acute Myocardial Ischemia by Vessel-Specific Leads Derived from the 12-Lead Electrocardiogram
    Wang, J. Y.
    Mirmoghisi, M.
    Warren, J. W.
    Wagner, G. S.
    Horacek, B. M.
    COMPUTERS IN CARDIOLOGY 2007, VOL 34, 2007, 34 : 301 - +
  • [8] Vectorcardiogram synthesized from the 12-lead electrocardiogram to image ischemia
    Strauss, David G.
    Olson, Charles W.
    Wu, Katherine C.
    Heiberg, Einar
    Persson, Eva
    Selvester, Ronald H.
    Pahlm, Olle
    Arheden, Hakan
    JOURNAL OF ELECTROCARDIOLOGY, 2009, 42 (02) : 190 - 197
  • [9] Accuracy of QT measurement in the EASI-derived 12-lead ECG
    Martinez, Juan Pablo
    Laguna, Pablo
    Olmos, Salvador
    Pahlm, Olle
    Petersson, Jonas
    Sornmo, Leif
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 4192 - +
  • [10] Reconstruction of the 12-lead electrocardiogram from reduced lead sets
    Nelwan, SP
    Kors, JA
    Meij, SH
    van Bemmel, JH
    Simoons, ML
    JOURNAL OF ELECTROCARDIOLOGY, 2004, 37 (01) : 11 - 18