Application of flow cytometry in detection of red cell bound IgG in Coombs negative AIHA

被引:35
作者
Chaudhary, Rajendra
Das, Sudipta S.
Gupta, Ritu
Khetan, Dheeraj
机构
[1] Sanjay Gandhi Postgrad Inst Med Sci, Dept Transfus Med, Lucknow 226014, Uttar Pradesh, India
[2] Sanjay Gandhi Postgrad Inst Med Sci, Dept Haematol, Lucknow, Uttar Pradesh, India
关键词
hemolysis; autoimmune hemolytic anemia; Coomb's test; flow cytometry; gel technology;
D O I
10.1080/10245330600915958
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Coombs negative autoimmune hemolytic anemia (AIHA) is characterized by laboratory evidence of in vivo hemolysis along with a negative direct antiglobulin test (DAT) performed by conventional tube technique (CTT) in clinically suspected AIHA patients. The sensitive gel test (GT) and flow cytometry (FC) can effectively diagnose such patients where CTT does riot detect low level of red cell autoantibodies. We investigated the use of FC in the serological evaluation of CTT DAT negative AIHA and its comparison with GT DAT. Of the 50 patients with suspected AIHA, CTT DAT was negative in 5 patients (Coombs negative AIHA). GT DAT could detect red cell autoantibodies in 4 of these 5 patients. Monospecific GT DAT showed IgG and/or C3d as the responsible autoantibody. FC was considered as reactive when MFI was > 3.6 (mean of 20 healthy negative volunteers + 2SD). FC was reactive in all five Coombs negative AIHA patients. The mean MFI in five known CTT DAT positive samples taken for comparison was significantly higher compared to 5 DAT negative AIHA (18.3 +/- 7.78 vs. 7.88 +/- 1.35, p < 0.05). There was poor correlation between strength of GT DAT and MFI by FC. We conclude that FC is more sensitive test than the CTT and helps in the serological diagnosis of Coombs negative AIHA. However, in resource poor settings, GT DAT can be a good alternative to FC.
引用
收藏
页码:295 / 300
页数:6
相关论文
共 19 条
  • [11] Kondo H, 1998, INT J HEMATOL, V68, P439
  • [12] A newly developed gel centrifugation test for quantification of RBC-bound IgG antibodies and their subclasses IgG1 and IgG3:: comparison with flow cytometry
    Lynen, R
    Krone, O
    Legler, TJ
    Köhler, M
    Mayr, WR
    [J]. TRANSFUSION, 2002, 42 (05) : 612 - 618
  • [13] Lynen R., 1997, ASPECTS FLOW CYTOMET, P59
  • [14] Comparison between the conventional tube technique and the gel technique in direct antiglobulin tests
    Nathalang, O
    Chuansumrit, A
    Prayoonwiwat, W
    Siripoonya, P
    Sriphaisal, T
    [J]. VOX SANGUINIS, 1997, 72 (03) : 169 - 171
  • [15] An automatable format for accurate immunohematology testing by flow cytometry
    Roback, JD
    Barclay, S
    Hillyer, CD
    [J]. TRANSFUSION, 2003, 43 (07) : 918 - 927
  • [16] Schreiber A, 1993, HEMATOLOGY INFANCY C, P496
  • [17] A preliminary comparison of flow cytometry and tube agglutination assays in detecting red blood cell-associated C3d
    Stroncek, DF
    Njoroge, JM
    Procter, JL
    Childs, RW
    Miller, J
    [J]. TRANSFUSION MEDICINE, 2003, 13 (01) : 35 - 41
  • [18] Detection of red blood cell-bound immunoglobulin G by flow cytometry and its application in the diagnosis of autoimmune hemolytic anemia
    Wang, ZY
    Shi, JW
    Zhou, YL
    Ruan, CG
    [J]. INTERNATIONAL JOURNAL OF HEMATOLOGY, 2001, 73 (02) : 188 - 193
  • [19] PHAGOCYTOSIS OF ERYTHROCYTES SENSITIZED WITH KNOWN AMOUNTS OF IGG1 AND IGG3 ANTI-RH ANTIBODIES
    ZUPANSKA, B
    THOMPSON, E
    BROJER, E
    MERRY, AH
    [J]. VOX SANGUINIS, 1987, 53 (02) : 96 - 101