Determination of parabens in cosmetic products using multi-walled carbon nanotubes as solid phase extraction sorbent and corona-charged aerosol detection system

被引:116
作者
Marquez-Sillero, Isabel [1 ]
Aguilera-Herrador, Eva [1 ]
Cardenas, Soledad [1 ]
Valcarcel, Miguel [1 ]
机构
[1] Univ Cordoba, Dept Analyt Chem, E-14071 Cordoba, Spain
关键词
Parabens; Cosmetics; Carbon nanotubes; Solid phase extraction; Charged aerosol detector; PERFORMANCE LIQUID-CHROMATOGRAPHY; TANDEM MASS-SPECTROMETRY; PERSONAL-CARE PRODUCTS; CAPILLARY-ELECTROPHORESIS; WATER SAMPLES; MICROEXTRACTION; HPLC; QUANTIFICATION; PRESERVATIVES; PORK;
D O I
10.1016/j.chroma.2009.11.005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The potential of carbon nanotubes for the solid phase extraction of parabens in cosmetic products and the detection using a corona-charged aerosol detector (C-CAD) is presented in this work. The analytical procedure is based on a conventional solid phase extraction step for which 20 mg of multi-walled carbon nanotubes were packed in a 3-mL commercial SPE cartridge. Methylparaben, ethylparaben, propylparaben and butylparaben were thus isolated and preconcentrated from the pre-treated samples and subsequently separated on RP-C18 column using acetonitrile:water, 50:50 (v/v) as mobile phase. The analytical signals for the individual parabens were obtained using C-CAD. The experimental variables affecting the extraction procedure and the instrumental detection have been deeply studied. Limits of detection were in the range of 0.5-2.1 mgL(-1), while the linear range was extended up to 400 mg L-1. The average precision of the method varied between 3.3-3.8% (repeatability) and 4.3-7.6% (reproducibility). Finally, the optimized procedure was applied to the determination of the target preservatives in a variety of cosmetic products with satisfactory results. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 40 条
[1]   Simultaneous determination of p-hydroxybenzoic acid and parabens by capillary electrophoresis with improved sensitivity in nonaqueous media [J].
Blanco, Eva ;
del Carmen Casais, Maria ;
del Carmen Mejuto, Maria ;
Cela, Rafael .
ELECTROPHORESIS, 2008, 29 (15) :3229-3238
[2]   Pressurized liquid extraction with in-cell clean-up followed by gas chromatography-tandem mass spectrometry for the selective determination of parabens and triclosan in indoor dust [J].
Canosa, P. ;
Perez-Palacios, D. ;
Garrido-Lopez, A. ;
Tena, M. T. ;
Rodriguez, I. ;
Rubi, E. ;
Cela, R. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1161 (1-2) :105-112
[3]   Optimisation of a solid-phase microextraction method for the determination of parabens in water samples at the low ng per litre level [J].
Canosa, P. ;
Rodriguez, I. ;
Rubi, E. ;
Bollain, M. H. ;
Cela, R. .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1124 (1-2) :3-10
[4]   PRE-COLUMN REACTIONS TO ELIMINATE INTERFERENTS IN LIQUID-CHROMATOGRAPHIC ANALYSIS OF PARA-HYDROXYBENZOATES IN COMPLEX PHARMACEUTICALS [J].
CANTWELL, FF .
ANALYTICAL CHEMISTRY, 1976, 48 (13) :1854-1859
[5]   Paraben esters: review of recent studies of endocrine toxicity, absorption, esterase and human exposure, and discussion of potential human health risks [J].
Darbre, Philippa D. ;
Harvey, Philip W. .
JOURNAL OF APPLIED TOXICOLOGY, 2008, 28 (05) :561-578
[6]   Quantification of pegylated phospholipids decorating polymeric microcapsules of perfluorooctyl bromide by reverse phase HPLC with a charged aerosol detector [J].
Diaz-Lopez, R. ;
Libong, D. ;
Tsapis, N. ;
Fattal, E. ;
Chaminade, P. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (03) :702-707
[7]   Multiwalled carbon nanotubes as sorbent for on-line coupling of solid-phase extraction to high-performance liquid chromatography for simultaneous determination of 10 sulfonamides in eggs and pork [J].
Fang, Guo-Zhen ;
He, Jin-Xing ;
Wang, Shuo .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1127 (1-2) :12-17
[8]  
Gamache PH, 2005, LC GC EUR, V18, P345
[9]   A review of the endocrine activity of parabens and implications for potential risks to human health [J].
Golden, R ;
Gandy, J ;
Vollmer, G .
CRITICAL REVIEWS IN TOXICOLOGY, 2005, 35 (05) :435-458
[10]   Universal response in liquid chromatography using charged aerosol detection [J].
Gorecki, Tadeusz ;
Lynen, Frederic ;
Szucs, Roman ;
Sandra, Pat .
ANALYTICAL CHEMISTRY, 2006, 78 (09) :3186-3192