Assessment of left ventricular function in non-dilated and dilated hearts: Comparison of contrast-enhanced 2-dimensional echocardiography with multi-detector row CT angiography

被引:9
作者
Burianova, Lucie [1 ]
Riedlbauchova, Lucie [1 ]
Lefflerova, Katerina [1 ]
Marek, Tomas [1 ]
Lupinek, Petr [1 ]
Kautznerova, Dana [2 ]
Vedlich, Daniel [2 ]
Lanska, Vera [3 ]
Kautzner, Josef [1 ]
机构
[1] Inst Clin & Expt Med, Dept Cardiol, Prague 14021 4, Czech Republic
[2] Inst Clin & Expt Med, Dept Radiodiagnost & Intervent Radiol, Prague 14021 4, Czech Republic
[3] Inst Clin & Expt Med, Dept Stat, Prague 14021 4, Czech Republic
关键词
Echocardiography; CT angiography; left ventricular volume; left ventricular function; COMPUTED-TOMOGRAPHY; MYOCARDIAL-INFARCTION; CORONARY-ANGIOGRAPHY; EJECTION FRACTION; ACCURACY; SOFTWARE; SURVIVAL; VOLUMES; MASS;
D O I
10.2143/AC.64.6.2044744
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective - Multidetector-row CT (MDCT) and contrast-enhanced echocardiography (CEE) are being increasingly used for assessment of left ventricular (LV) function. Excellent spatial and contrast resolution of MDCT allows this evaluation along with coronary angiography. CEE improves the accuracy of 2D echocardiography. Data on side-by-side comparison of both techniques for assessment of LV size and function in subjects with a non-dilated or dilated left ventricle are limited. Methods and results - Our study population included 64 patients. Group I included 31 patients with an implanted pacemaker who had a non-dilated left ventricle with preserved systolic function. Group II comprised 33 patients with dilated cardiomyopathy and severe systolic LV dysfunction. LV end-diastolic and end-systolic volumes (LVEDV, LVESV) and ejection fraction (LVEF) were assessed using both CEE and short-axis MDCT. The results obtained by both techniques were compared by linear regression and Bland-Altman analysis. Additionally, intra- and interobserver reproducibility was assessed. Both CEE and MDCT measurements highly correlated (r = 0.61-0.94). However, CEE significantly underestimated LVEDV and LVESV, and this bias was higher with enlarged LV volumes. LVEF was overestimated by CEE in both groups with a higher bias in the group with preserved systolic function. Both intra- and interobserver reproducibility was significantly better for MDCT the worst reproducibility was observed for CEE in group I. Conclusion - Despite a high correlation between MDCT and CEE measurements, CEE provides consistently lower volumes and higher LVEF. This suggests that both methods are not completely interchangeable. Reproducibility of CEE is inferior to reproducibility of MDCT, especially in non-dilated left ventricles with preserved function.
引用
收藏
页码:787 / 794
页数:8
相关论文
共 27 条
  • [1] Assessment of ventricular function and mass by cardiac magnetic resonance imaging
    Alfakih, K
    Reid, S
    Jones, T
    Sivananthan, M
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (10) : 1813 - 1822
  • [2] Assessment of left ventricular function: comparison of cardiac multidetector-row computed tomography with two-dimension standard echocardiography for assessment of left ventricular function
    Bansal, Darpan
    Singh, Robin M.
    Sarkar, Mrinalini
    Sureddi, Ravi
    Mcbreen, Kelly C.
    Griffis, Timothy
    Sinha, Anjan
    Mehta, Jawahar L.
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2008, 24 (03) : 317 - 325
  • [3] Measuring agreement in method comparison studies
    Bland, JM
    Altman, DG
    [J]. STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) : 135 - 160
  • [4] *EMEA, EUR AG EV MED PROD
  • [5] LONG-TERM SURVIVAL OF MEDICALLY TREATED PATIENTS IN THE CORONARY-ARTERY SURGERY STUDY (CASS) REGISTRY
    EMOND, M
    MOCK, MB
    DAVIS, KB
    FISHER, LD
    HOLMES, DR
    CHAITMAN, BR
    KAISER, GC
    ALDERMAN, E
    KILLIP, T
    [J]. CIRCULATION, 1994, 90 (06) : 2645 - 2657
  • [6] Evaluation of global left ventricular myocardial function with electrocardiogram-gated multidetector computed tomography - Comparison with magnetic resonance imaging
    Grude, M
    Juergens, KU
    Wichter, T
    Paul, M
    Fallenberg, EM
    Muller, JG
    Heindel, W
    Breithardt, G
    Fischbach, R
    [J]. INVESTIGATIVE RADIOLOGY, 2003, 38 (10) : 653 - 661
  • [7] Assessment of global and regional left ventricular function and volumes with 64-slice MSCT: A comparison with 2D echocardiography
    Henneman, Maureen M.
    Schuijf, Joanne D.
    Jukema, J. Wouter
    Holman, Eduard R.
    Lamb, Hildo J.
    de Roos, Albert
    van der Wall, Ernst E.
    Bax, Jeroen J.
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2006, 13 (04) : 480 - 487
  • [8] Assessment of left ventricular myocardial function using 16-slice multidetector-row computed tomography: comparison with magnetic resonance imaging and echocardiography
    Heuschmid, M
    Rothfuss, JK
    Schroeder, S
    Fenchel, M
    Stauder, N
    Burgstahler, C
    Franow, A
    Kuzo, RS
    Kuettner, A
    Miller, S
    Claussen, CD
    Kopp, AF
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (03) : 551 - 559
  • [9] Assessment of systolic left ventricular function: a multi-centre comparison of cineventriculography, cardiac magnetic resonance imaging, unenhanced and contrast-enhanced echocardiography
    Hoffmann, R
    von Bardeleben, S
    ten Cate, F
    Borges, AC
    Kasprzak, J
    Firschke, C
    Lafitte, S
    Al-Saadi, N
    Kuntz-Hehner, S
    Engelhardt, M
    Becher, H
    Vanoverschelde, JL
    [J]. EUROPEAN HEART JOURNAL, 2005, 26 (06) : 607 - 616
  • [10] ECG-gated reconstructed multi-detector row CT coronary angiography:: Effect of varying trigger delay on image quality
    Hong, C
    Becker, CR
    Huber, A
    Schoepf, UJ
    Ohnesorge, B
    Knez, A
    Brüning, R
    Reiser, MF
    [J]. RADIOLOGY, 2001, 220 (03) : 712 - 717