High spatial resolution speckle tracking improves accuracy of 2-dimensional strain measurements: An update on a new method in functional echocardiography

被引:76
作者
Korinek, Josef
Kjaergaard, Jesper
Sengupta, Partho P.
Yoshifuku, Shiro
McMahon, Eileen M.
Cha, Stephen S.
Khandheria, Bijoy K.
Belohlavek, Marek
机构
[1] Mayo Clin & Mayo Fdn, Mayo Clin Coll Med, Dept Internal Med, Div Cardiovasc Dis, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Mayo Clin Coll Med, Dept Hlth Sci Res, Div Biostat, Rochester, MN 55905 USA
关键词
D O I
10.1016/j.echo.2006.08.031
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We previously found that a 2-dimensional (2D) strain echocardiography method had some limitations in the assessment of low magnitudes and rates of deformation. Here, we study whether a recently introduced high spatial resolution speckle tracking (HRT) method improves accuracy of 2D strain measurements. Methods: A gelatin block was cyclically compressed by a hydraulic piston. Regional deformations measured by 2D-HRT were compared with reference strains obtained from an embedded pair of sonomicrometry crystals. Global deformations (along the gelatin block) were compared to strains calculated from tracings of piston motion. We tested a wide range of strains (5.4%-21.5%) and combined each measurement with simulated heart rates (24-196/min). Results: Regional deformations measured by 2D-HRT demonstrated excellent correlation (r = 0.99, P <.0001) and agreement (bias +/- 2SD = -0.3 +/- 1.3%) with sonomicrometry. Close correlation (r 0.99, P <.0001) and agreement (bias +/- 2SD = 0.5 +/- 1.2%) was observed also for global strains measured by 2D-HRT and compared with tracings of piston motion. There was good reproducibility of all tests: interobserver and intraobserver variabilities were 3.2% and 3.4% for regional strains and 3.1% and 3.5% for global strains, respectively. Conclusion: In our in vitro setting, the 2D-HRT method produced precise and accurate measurements of strains for clinically relevant ranges of deformation magnitudes and ranges.
引用
收藏
页码:165 / 170
页数:6
相关论文
共 25 条
[1]   Noninvasive myocardial strain measurement by speckle tracking echocardiography - Validation against sonomicrometry and tagged magnetic resonance imaging [J].
Amundsen, BH ;
Helle-Valle, T ;
Edvardsen, T ;
Torp, H ;
Crosby, J ;
Lyseggen, E ;
Stoylen, A ;
Ihlen, H ;
Lima, JAC ;
Smiseth, OA ;
Slordahl, SA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) :789-793
[2]   Analysis of myocardial deformation based on pixel tracking in two dimensional echocardiographic images enables quantitative assessment of regional left ventricular function [J].
Becker, M. ;
Bilke, E. ;
Kuehl, H. ;
Katoh, M. ;
Kramann, R. ;
Franke, A. ;
Buecker, A. ;
Hanrath, P. ;
Hoffmann, R. .
HEART, 2006, 92 (08) :1102-1108
[3]   Improving motion estimation by accounting for local image distortion [J].
Behar, V ;
Adam, D ;
Lysyansky, P ;
Friedman, Z .
ULTRASONICS, 2004, 43 (01) :57-65
[4]   Real-time strain rate imaging: Validation of peak compression and expansion rates by a tissue-mimicking phantom [J].
Belohlavek, M ;
Bartleson, VB ;
Zobitz, ME .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (07) :565-571
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]  
Castro PL, 2000, BIOMED SCI INSTRUM, V395, P197
[7]   Echocardiographic strain and strain-rate imaging: A new tool to study regional myocardial function [J].
D'hooge, J ;
Bijnens, B ;
Thoen, J ;
Van de Werf, F ;
Sutherland, GR ;
Suetens, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (09) :1022-1030
[8]   Quantitative assessment of intrinsic regional myocardial deformation by Doppler strain rate echocardiography in humans - Validation against three-dimensional tagged magnetic resonance imaging [J].
Edvardsen, T ;
Gerber, BL ;
Garot, J ;
Bluemke, DA ;
Lima, JAC ;
Smiseth, OA .
CIRCULATION, 2002, 106 (01) :50-56
[9]   Quantification of left ventricular systolic function by tissue Doppler echocardiography - Added value of measuring pre- and postejection velocities in ischemic myocardium [J].
Edvardsen, T ;
Urheim, S ;
Skulstad, H ;
Steine, K ;
Ihlen, H ;
Smiseth, OA .
CIRCULATION, 2002, 105 (17) :2071-2077
[10]   Accuracy, reproducibility, and comparability of Doppler tissue imaging by two high-end ultrasound systems [J].
Kjaergaard, J ;
Korinek, J ;
Belohlavek, M ;
Oh, JK ;
Sogaard, P ;
Hassager, C .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2006, 19 (03) :322-328