Prediction of fractional flow reserve with angiographic DILEMMA score

被引:5
作者
Beton, Osman [1 ]
Kaya, Hakki [1 ]
Turgut, Okan Onur [1 ]
Yilmaz, Mehmet Birhan [1 ]
机构
[1] Cumhuriyet Univ, Hlth Serv Training & Res Hosp, Heart Ctr, Dept Cardiol, Sivas, Turkey
关键词
DILEMMA score; fractional flow reserve; pressure wire analyses; resting Pd/Pa;
D O I
10.14744/AnatolJCardiol.2016.7379
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Angiographic assessment of stenosis has limited predictive value for functionally significant lesions compared with fractional flow reserve (FFR). The recently developed angiographic DILEMMA score, which consists of minimal lumen diameter (MLD), lesion length (LL) and Bypass Angioplasty Revascularization Investigation (BARI) Myocardial Jeopardy Index (MJI) was found to have diagnostic value in predicting FFR <= 0.80. The present study was an investigation of prediction of FFR <= 0.80 using DILEMMA score and its relationship to resting distal coronary artery pressure/aortic pressure (Pd/Pa). Methods: Records of consecutive patients who underwent coronary angiography and FFR were retrospectively analyzed. Assessment of MLD and LL was performed using quantitative coronary angiography. BARI MJI was calculated using angiographic calculation index. Results: A total of 185 pressure wire analysis data sets from 150 patients were analyzed retrospectively. There were 82 lesions in FFR >0.80 group and 103 lesions in FFR <= 0.80 group. Negative correlation was found between FFR and DILEMMA score (r=-0.494; p<0.001), FFR and BARI-MJI (r=0.378; p<0.001), and between FFR and LL (r=-0.314; p<0.001). Positive correlation was found between FFR and baseline Pd/Pa (r=0.713; p<0.001), and between FFR and MLD (r=0.415; p<0.001). DILEMMA score had negative correlation with resting Pd/Pa (r=-0.389; p<0.001). In receiver opera-ting characteristic analysis for diagnosing FFR <= 0.80, area under curve values of resting Pd/Pa, DILEMMA score, MLD, BARI-MJI, and LL were 0.862, 0.793, 0.780, 0.728, and 0.686, respectively. Conclusion: DILEMMA score had moderately strong correlation with FFR and good accuracy in diagnosing significant FFR, but it had weak correlation with resting Pd/Pa.
引用
收藏
页码:285 / 292
页数:8
相关论文
共 31 条
[1]  
ALDERMAN EL, 1992, CORONARY ARTERY DIS, V3, P1189
[2]   Native coronary disease progression exceeds failed revascularization as cause of angina after five years in the bypass Angioplasty Revascularization Investigation (BARI) [J].
Alderman, EL ;
Kip, KE ;
Whitlow, PL ;
Bashore, T ;
Fortin, D ;
Bourassa, MG ;
Lesperance, J ;
Schwartz, L ;
Stadius, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (04) :766-774
[3]   EFFECT OF PERFUSION-PRESSURE DISTAL TO A CORONARY STENOSIS ON TRANSMURAL MYOCARDIAL BLOOD-FLOW [J].
BACHE, RJ ;
SCHWARTZ, JS .
CIRCULATION, 1982, 65 (05) :928-935
[4]   Agreed Statistics Measurement Method Comparison [J].
Bland, J. Martin ;
Altman, Douglas G. .
ANESTHESIOLOGY, 2012, 116 (01) :182-185
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Effect of lesion length on fractional flow reserve in intermediate coronary lesions [J].
Brosh, D ;
Higano, ST ;
Lennon, RJ ;
Holmes, DR ;
Lerman, A .
AMERICAN HEART JOURNAL, 2005, 150 (02) :338-343
[7]   Scaling of myocardial mass to flow and morphometry of coronary arteries [J].
Choy, Jenny Susana ;
Kassab, Ghassan S. .
JOURNAL OF APPLIED PHYSIOLOGY, 2008, 104 (05) :1281-1286
[8]   Contemporary Patterns of Fractional Flow Reserve and Intravascular Ultrasound Use Among Patients Undergoing Percutaneous Coronary Intervention in the United States Insights From the National Cardiovascular Data Registry [J].
Dattilo, Philip B. ;
Prasad, Anand ;
Honeycutt, Emily ;
Wang, Tracy Y. ;
Messenger, John C. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (22) :2337-2339
[9]   Invasive Coronary Physiology for Assessing Intermediate Lesions [J].
Fearon, William F. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (02)
[10]   EQUIVALENCE OF WEIGHTED KAPPA AND INTRACLASS CORRELATION COEFFICIENT AS MEASURES OF RELIABILITY [J].
FLEISS, JL ;
COHEN, J .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1973, 33 (03) :613-619