Effects of boundary restraints on concrete-filled steel tubular columns with reinforcements exposed to fire

被引:13
作者
Guo, Zhen [1 ,2 ]
Wang, Xing [2 ]
Zhang, Xuecheng [2 ]
Song, Jun [2 ]
Li, Chenfeng [3 ]
机构
[1] China Univ Min & Technol, Jiangsu Key Lab Environm Impact & Struct Safety E, Xuzhou, Jiangsu, Peoples R China
[2] China Univ Min & Technol, Sch Mech & Civil Engn, Xuzhou 221116, Jiangsu, Peoples R China
[3] Harbin Engn Univ, Coll Shipbldg Engn, Harbin 150001, Heilongjiang, Peoples R China
关键词
CFST column; Fire behaviour; Eccentricity ratio; Slenderness ratio; Boundary condition; COMPOSITE COLUMNS; RESISTANCE; SLENDER; PERFORMANCE; BEHAVIOR; TEMPERATURE; AMBIENT;
D O I
10.1016/j.tws.2019.04.057
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study examines the fire responses of restrained concrete-filled steel tubular (CFST) columns subjected to axial and eccentric loads using high-temperature experiments. A new type of reaction steel frame was used to simulate the restraint stiffness of the boundary, and a set of adjustable knife-edge articulation systems provided the required end eccentricities and pin supports. Using this type of installation, the fire-resistances of CFST columns with finite restraint stiffnesses and different eccentricities were investigated and discussed. The experimental results indicate that low slenderness ratios can reduce the bending deformation and release the reaction forces induced by thermal actions. Owing to their high thermal capacities, large-scale specimens absorb more heat and are slow to heat up. When the eccentricity ratios exceed 0.33, the elongation increments are reduced. However, low eccentricity ratios cause the thermal reaction forces to quickly decay. The load is gradually redistributed to the surrounding structures through rigid connections between the columns and surrounding structures. Owing to the benefit of rotational restraints, the maximum reaction force ratios of fixed CFST columns accounted for 84%-86% of those of pinned CFST columns.
引用
收藏
页码:52 / 63
页数:12
相关论文
共 36 条
  • [1] Structural performance of rotationally restrained steel columns in fire
    Ali, F
    O'Connor, D
    [J]. FIRE SAFETY JOURNAL, 2001, 36 (07) : 679 - 691
  • [2] Dehydration and rehydration processes of cement paste exposed to high temperature environments
    Alonso, C
    Fernandez, L
    [J]. JOURNAL OF MATERIALS SCIENCE, 2004, 39 (09) : 3015 - 3024
  • [3] [Anonymous], 2012, CECS282012
  • [4] Shape effect on the behaviour of axially loaded concrete filled steel tubular stub columns at elevated temperature
    Dai, X. H.
    Lam, D.
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 73 : 117 - 127
  • [5] Circular and square slender concrete-filled tubular columns under large eccentricities and fire
    Espinos, A.
    Romero, M. L.
    Serra, E.
    Hospitaler, A.
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 110 : 90 - 100
  • [6] Ambient and fire behavior of eccentrically loaded elliptical slender concrete-filled tubular columns
    Espinos, A.
    Romero, M. L.
    Portoles, J. M.
    Hospitaler, A.
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 100 : 97 - 107
  • [7] Simple calculation model for evaluating the fire resistance of unreinforced concrete filled tubular columns
    Espinos, Ana
    Romero, Manuel L.
    Hospitaler, Antonio
    [J]. ENGINEERING STRUCTURES, 2012, 42 : 231 - 244
  • [8] Fire resistance of concrete filled steel tube columns subjected to non-uniform heating
    Guo, Hongcun
    Long, Xu
    Yao, Yao
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 128 : 542 - 554
  • [9] Experimental and computational study of concrete filled steel tubular columns under axial loads
    Gupta, P. K.
    Sarda, S. M.
    Kumar, M. S.
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2007, 63 (02) : 182 - 193
  • [10] An experimental study and calculation on the fire resistance of concrete-filled SHS and RHS columns
    Han, LH
    Yang, YF
    Xu, L