Serial registration of intraoperative MR images of the brain

被引:138
作者
Ferrant, M
Nabavi, A
Macq, B
Black, PM
Jolesz, FA
Kikinis, R
Warfield, SK [1 ]
机构
[1] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Radiol,Surg Planning Lab, Boston, MA 02115 USA
[2] Catholic Univ Louvain, Commun & Remote Sensing Lab, B-1348 Louvain, Belgium
[3] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Neurosurg, Boston, MA 02115 USA
[4] Univ Kiel, Dept Neurosurg, Kiel, Germany
关键词
D O I
10.1016/S1361-8415(02)00060-9
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The increased use of image-guided surgery systems during neurosurgery has brought to prominence the inaccuracies of conventional intraoperative navigation systems caused by shape changes such as those due to brain shift. We propose a method to track the deformation of the brain and update preoperative images using intraoperative MR images acquired at different crucial time points during surgery. We use a deformable, surface matching algorithm to capture the deformation of boundaries of key structures (cortical surface, ventricles and tumor) throughout the neurosurgical procedure, and a linear finite element elastic model to infer a volumetric deformation. The boundary data are extracted from intraoperative MR images using a real-time intraoperative segmentation algorithm. The algorithm has been applied to a sequence of intraoperative MR images of the brain exhibiting brain shift and tumor resection. Our results characterize the brain shift after opening of the dura and at the different stages of tumor resection, and brain swelling afterwards. Analysis of the average deformation capture was assessed by comparing landmarks identified manually and the results indicate an accuracy of 0.7+/-0.6 mm (mean+/-S.D.) for boundary surface landmarks, of 0.9+/-0.6 mm for landmarks inside the boundary surfaces, and 1.6+/-0.9 mm for landmarks in the vicinity of the tumor. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:337 / 359
页数:23
相关论文
共 86 条
[21]   ELASTICALLY DEFORMING 3D ATLAS TO MATCH ANATOMICAL BRAIN IMAGES [J].
GEE, JC ;
REIVICH, M ;
BAJCSY, R .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1993, 17 (02) :225-236
[22]  
Gering DT, 1999, LECT NOTES COMPUT SC, V1679, P809
[23]   An automatic registration method for frameless stereotaxy, image guided surgery, and enhanced reality visualization [J].
Grimson, WEL ;
Ettinger, GJ ;
White, SJ ;
LozanoPerez, T ;
Wells, WM ;
Kikinis, R .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (02) :129-140
[24]   Three-dimensional multimodal brain warping using the demons algorithm and adaptive intensity corrections [J].
Guimond, A ;
Roche, A ;
Ayache, N ;
Meunier, J .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (01) :58-69
[25]  
Haber E, 1998, LECT NOTES COMPUT SC, V1496, P177, DOI 10.1007/BFb0056200
[26]   Biomechanical modeling of the human head for physically based, nonrigid image registration [J].
Hagemann, A ;
Rohr, K ;
Stiehl, HS ;
Spetzger, U ;
Gilsbach, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (10) :875-884
[27]  
Hart P.E., 1973, Pattern recognition and scene analysis
[28]   Registration techniques for the analysis of the brain shift in neurosurgery [J].
Hastreiter, P ;
Rezk-Salama, C ;
Nimsky, C ;
Lürig, C ;
Greiner, G ;
Ertl, T .
COMPUTERS & GRAPHICS-UK, 2000, 24 (03) :385-389
[29]  
Hata N, 1998, LECT NOTES COMPUT SC, V1496, P1067, DOI 10.1007/BFb0056296
[30]   Three-dimensional optical flow method for measurement of volumetric brain deformation from intraoperative MR images [J].
Hata, N ;
Nabavi, A ;
Wells, WM ;
Warfield, SK ;
Kikinis, R ;
Black, PM ;
Jolesz, FA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (04) :531-538