Performance evaluation of chairlift ropes in two man-riding systems in an incline coal mine using a non-destructive testing instrument

被引:1
作者
Basak, D. [1 ]
机构
[1] CSIR Cent Inst Min & Fuel Res, Elect Lab, Barwa Rd, Dhanbad 826015, Bihar, India
关键词
magnetic flux leakage; magnetic methods; wear;
D O I
10.1784/insi.2016.58.4.206
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Electromagnetic non-destructive testing/evaluation is an important means for assessment of the performance of chairlift ropes in a mining installation. The visual method produces the possibility of inadequate inspection due to its subjectivity. Magnetic flaw detectors, which measure loss of metallic area (LMA) and detect local faults (LF), such as broken wires and other faults of the ropes, are used to determine rope wear. Regular non-destructive evaluation/testing (NDE/NDT) inspections provide a powerful tool for monitoring the rate of degradation of a rope. The effective technology for these devices depends on the magnetic properties of the steel wire rope. An attempt has been made in this paper to evaluate the performance of ropes in two chairlift man-riding systems in an incline coal mine in India.
引用
收藏
页码:206 / 209
页数:4
相关论文
共 5 条
[1]   Performance evaluation of a haulage rope using two non-destructive testing instruments [J].
Basak, D. ;
Das, B. .
INSIGHT, 2013, 55 (01) :21-23
[2]  
BASAK D, 2014, INT J COMPUTATIONAL, V17, P21
[3]  
MIRONENKO AS, 2006, PODEMNYE SOORUZHENIY, P52
[4]  
Sukhorukov V, PERIODIC NONDESTRUCT
[5]  
University of Reading, 2000, 2000064 OTO U READ U