Improved Performance of a PV Integrated Ventilated Facade at an Existing nZEB

被引:4
作者
Tejero-Gonzalez, Ana [1 ,2 ]
Krawczyk, Dorota Anna [3 ]
Garcia, Jose Ramon Martin-Sanz [4 ]
Javier Rey-Martinez, Francisco [1 ,2 ]
Velasco-Gomez, Eloy [1 ,2 ]
机构
[1] Univ Valladolid, Dept Energy & Fluidmech, Sch Engn, Paseo Cauce 59, E-47011 Valladolid, Spain
[2] Univ Valladolid, Sch Engn, ITAP, E-47011 Valladolid, Spain
[3] Bialystok Tech Univ, Fac Civil Engn & Environm Engn, Dept HVAC Engn, Wiejska 45E, PL-15351 Bialystok, Poland
[4] Veolia Australia & New Zealand, 65 Pirrama Rd, Pyrmont, NSW 2009, Australia
关键词
ventilated facade; photovoltaics; monitoring; model validation; energy conservation measure; DOUBLE-SKIN FACADES; FORCED-CONVECTION; GLAZED FACADES; SIMULATION; ENERGY; MODEL;
D O I
10.3390/en12153033
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Ventilated facades are among the existing measures to reduce the energy demand in buildings. The combination of this passive heating and cooling strategy with photovoltaics (PV) can drive new buildings towards the current European targets near or even to net zero energy Buildings (nZEB). The present work studies the thermal behavior of the PV integrated ventilated facade applied in the nZEB known as LUCIA (acronym in Spanish for University Centre to Launch Applied Research) at the University of Valladolid, Spain. The aim is to evaluate the interest of recirculating indoor air within the facade during winter, as an alternative to the present preferred operating mode during the target season, in which the facade acts as further insulation. First, the radiant properties of the PV facade are measured to use the values in a mathematical model that describes the behavior of the ventilated facade in its current operating mode in winter. Then, the solar radiation available, the air-dry bulb temperatures indoors, outdoors and inside the ventilated facade are monitored to obtain experimental data to validate the model. The results show that air recirculation can entail favorable heat gains during 10% of winter, being this alternative preferable to the present operating mode when outdoor temperatures are over 18.4 degrees C.
引用
收藏
页数:14
相关论文
共 34 条
  • [11] Double skin glazed facades in sunny Mediterranean climates
    Flores Larsen, Silvana
    Rengifo, Luis
    Filippin, Celina
    [J]. ENERGY AND BUILDINGS, 2015, 102 : 18 - 31
  • [12] Modelling the heat dynamics of building integrated and ventilated photovoltaic modules
    Friling, Nynne
    Jose Jimenez, Maria
    Bloem, Hans
    Madsen, Henrik
    [J]. ENERGY AND BUILDINGS, 2009, 41 (10) : 1051 - 1057
  • [13] Data-driven performance evaluation of ventilated photovoltaic double-skin facades in the built environment
    Gaillard, Leon
    Ruedin, Guillaume
    Giroux-Julien, Stephanie
    Plantevit, Marc
    Kaytoue, Mehdi
    Saadon, Syamimi
    Menezo, Christophe
    Boulicaut, Jean-Francois
    [J]. 6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 447 - 452
  • [14] Experimental evaluation of a naturally ventilated PV double-skin building envelope in real operating conditions
    Gaillard, Leon
    Giroux-Julien, Stephanie
    Menezo, Christophe
    Pabiou, Herve
    [J]. SOLAR ENERGY, 2014, 103 : 223 - 241
  • [15] Effect of air gap on the performance of building-integrated photovoltaics
    Gan, Guohui
    [J]. ENERGY, 2009, 34 (07) : 913 - 921
  • [16] CFD assessment of the performance of lateral ventilation in Double Glazed Facades in Mediterranean climates
    Guardo, A.
    Coussirat, M.
    Valero, C.
    Egusquiza, E.
    Alavedra, P.
    [J]. ENERGY AND BUILDINGS, 2011, 43 (09) : 2539 - 2547
  • [17] Hailu G., 2014, COMPUTATIONAL FLUID
  • [18] Experimental and numerical investigation of forced convection in a double skin facade by using nodal network approach for Istanbul
    Inan, Tugba
    Basaran, Tahsin
    [J]. SOLAR ENERGY, 2019, 183 : 441 - 452
  • [19] An approach for energy modeling of a building integrated photovoltaic (BIPV) Trombe wall system
    Koyunbaba, Basak Kundakci
    Yilmaz, Zerrin
    Ulgen, Koray
    [J]. ENERGY AND BUILDINGS, 2013, 67 : 680 - 688
  • [20] Optimization and Evaluation of Naturally Ventilated BIPV Facade Design
    Lau, Siu-Kit
    Zhao, Yong
    Shabunko, Veronika
    Chao, Yuan
    Lau, Stephen Siu-Yu
    Tablada, Abel
    Reindl, Thomas
    [J]. PROCEEDINGS OF THE 12TH INTERNATIONAL PHOTOVOLTAIC POWER GENERATION AND SMART ENERGY CONFERENCE & EXHIBITION (SNEC2018), 2018, 150 : 87 - 93