Improved Performance of a PV Integrated Ventilated Facade at an Existing nZEB

被引:4
作者
Tejero-Gonzalez, Ana [1 ,2 ]
Krawczyk, Dorota Anna [3 ]
Garcia, Jose Ramon Martin-Sanz [4 ]
Javier Rey-Martinez, Francisco [1 ,2 ]
Velasco-Gomez, Eloy [1 ,2 ]
机构
[1] Univ Valladolid, Dept Energy & Fluidmech, Sch Engn, Paseo Cauce 59, E-47011 Valladolid, Spain
[2] Univ Valladolid, Sch Engn, ITAP, E-47011 Valladolid, Spain
[3] Bialystok Tech Univ, Fac Civil Engn & Environm Engn, Dept HVAC Engn, Wiejska 45E, PL-15351 Bialystok, Poland
[4] Veolia Australia & New Zealand, 65 Pirrama Rd, Pyrmont, NSW 2009, Australia
关键词
ventilated facade; photovoltaics; monitoring; model validation; energy conservation measure; DOUBLE-SKIN FACADES; FORCED-CONVECTION; GLAZED FACADES; SIMULATION; ENERGY; MODEL;
D O I
10.3390/en12153033
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Ventilated facades are among the existing measures to reduce the energy demand in buildings. The combination of this passive heating and cooling strategy with photovoltaics (PV) can drive new buildings towards the current European targets near or even to net zero energy Buildings (nZEB). The present work studies the thermal behavior of the PV integrated ventilated facade applied in the nZEB known as LUCIA (acronym in Spanish for University Centre to Launch Applied Research) at the University of Valladolid, Spain. The aim is to evaluate the interest of recirculating indoor air within the facade during winter, as an alternative to the present preferred operating mode during the target season, in which the facade acts as further insulation. First, the radiant properties of the PV facade are measured to use the values in a mathematical model that describes the behavior of the ventilated facade in its current operating mode in winter. Then, the solar radiation available, the air-dry bulb temperatures indoors, outdoors and inside the ventilated facade are monitored to obtain experimental data to validate the model. The results show that air recirculation can entail favorable heat gains during 10% of winter, being this alternative preferable to the present operating mode when outdoor temperatures are over 18.4 degrees C.
引用
收藏
页数:14
相关论文
共 34 条
  • [1] Part II: Thermal analysis of naturally ventilated BIPV system: Modeling and Simulation
    Agathokleous, Rafaela A.
    Kalogirou, Soteris A.
    [J]. SOLAR ENERGY, 2018, 169 : 682 - 691
  • [2] Experimental validation of a EnergyPlus model: Application of a multi-storey naturally ventilated double skin facade
    Andelkovic, Aleksandar S.
    Mujan, Igor
    Dakic, Stojanka
    [J]. ENERGY AND BUILDINGS, 2016, 118 : 27 - 36
  • [3] Transformation of an Office Building into a Nearly Zero Energy Building (nZEB): Implications for Thermal and Visual Comfort and Energy Performance
    Ballarini, Ilaria
    De Luca, Giovanna
    Paragamyan, Argun
    Pellegrino, Anna
    Corrado, Vincenzo
    [J]. ENERGIES, 2019, 12 (05)
  • [4] Experimental investigation of the pressure loss through a double skin facade by using perforated plates
    Basaran, Tahsin
    Inan, Tugba
    [J]. ENERGY AND BUILDINGS, 2016, 133 : 628 - 639
  • [5] Building-integrated PV modules
    Benemann, J
    Chehab, O
    Schaar-Gabriel, E
    [J]. SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2001, 67 (1-4) : 345 - 354
  • [6] Bergman T. L., 2011, FUNDAMENTALS HEAT MA
  • [7] A key review of building integrated photovoltaic (BIPV) systems
    Biyik, Emrah
    Araz, Mustafa
    Hepbasli, Arif
    Shahrestani, Mehdi
    Yao, Runming
    Shao, Li
    Essah, Emmanuel
    Oliveira, Armando C.
    del Cano, Teodosio
    Rico, Elena
    Luis Lechon, Juan
    Andrade, Luisa
    Mendes, Adelio
    Atli, Yusuf Baver
    [J]. ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2017, 20 (03): : 833 - 858
  • [8] Performance and influence of numerical sub-models on the CFD simulation of free and forced convection in double-glazed ventilated facades
    Coussirat, M.
    Guardo, A.
    Jou, E.
    Egusquiza, E.
    Cuerva, E.
    Alavedra, P.
    [J]. ENERGY AND BUILDINGS, 2008, 40 (10) : 1781 - 1789
  • [9] Naturally ventilated double-skin facade in modeling and experiments
    Dama, Alessandro
    Angeli, Diego
    Larsen, Olena Kalyanova
    [J]. ENERGY AND BUILDINGS, 2017, 144 : 17 - 29
  • [10] A simplified mathematical model for transient simulation of thermal performance and energy assessment for active facades
    Elarga, Hagar
    De Carli, Michele
    Zarrella, Angelo
    [J]. ENERGY AND BUILDINGS, 2015, 104 : 97 - 107