Automated workflow for volumetric assessment of signal intensity ratio on T1-weighted MR images after multiple gadolinium administrations

被引:0
|
作者
Liu, Chia-Ying [1 ]
Ramos, Marc [2 ]
Moreno-Dominguez, David [2 ]
Prckovska, Vesna [2 ]
Rodrigues, Paulo [2 ]
Blank, Markus [1 ]
Moser, Franklin G. [3 ]
Agris, Jacob [1 ]
机构
[1] Bayer HealthCare, US Med Affairs, Whippany, NJ 07981 USA
[2] QMENTA Inc, Boston, MA USA
[3] Cedars Sinai Med Ctr, S Mark Taper Fdn Imaging Ctr, Dept Imaging, Los Angeles, CA 90048 USA
关键词
GBCA; gadolinium retention; dentate nucleus; globus pallidus; DENTATE NUCLEUS; GLOBUS-PALLIDUS; GADODIAMIDE; DEPOSITION;
D O I
10.1117/1.JMI.8.1.014005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Repeated injections of linear gadolinium-based contrast agent (GBCA) have shown correlations with increased signal intensities (SI) on unenhanced T1-weighted (T1w) images. Assessment is usually performed manually on a single slice and the SI as an average of a free-hand region-of-interest is reported. We aim to develop a fully automated software that segments and computes SI ratio of dentate nucleus (DN) to pons (DN/P) and globus pallidus (GP) to thalamus (GP/T) for the assessment of gadolinium presence in the brain after a serial GBCA administrations. Approach: All patients (N = 113) underwent at least eight GBCA enhanced scans. The modal SI in the DN, GP, pons, and thalamus were measured volumetrically on unenhanced T1w images and corrected based on the reference protocol (measurement 1) and compared to the SI-uncorrected-modal-volume (measurement 2), SI-corrected-mean-volume (measurement 3), as well as SI-corrected-modal-single slice (measurement 4) approaches. Results: Automatic processing worked on all 2119 studies (1150 at 1.5 T and 969 at 3 T). DN/P were 1.085 +/- 0.048 (1.5 T) and 0.979 +/- 0.061 (3 T). GP/T were 1.084 +/- 0.039 (1.5 T) and 1.069 +/- 0.042 (3 T). Modal DN/P ratios from volumetric assessment at 1.5 T failed to show a statistical difference with or without SI corrections (p = 0.71). All other t-tests demonstrated significant differences (measurement 2, 3, 4 compared to 1, p < 0.001). Conclusion: The fully automatic method is an effective powerful tool to streamline the analysis of SI ratios in the deep brain tissues. Divergent SI ratios using different approaches reinforces the need to standardize the measurement for the research in this field. (C) 2021 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Signal Hyperintensity on Unenhanced T1-Weighted Brain and Cervical Spinal Cord MR Images after Multiple Doses of Linear Gadolinium-Based Contrast Agent
    Barisano, G.
    Bigjahan, B.
    Metting, S.
    Cen, S.
    Amezcua, L.
    Lerner, A.
    Toga, A. W.
    Law, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (08) : 1274 - 1281
  • [32] Pediatric Brain: No Increased Signal Intensity in the Dentate Nucleus on Unenhanced T1-weighted MR Images after Consecutive Exposure to a Macrocyclic Gadolinium-based Contrast Agent
    Radbruch, Alexander
    Haase, Robert
    Kickingereder, Philipp
    Baeumer, Philipp
    Bickelhaupt, Sebastian
    Paech, Daniel
    Wick, Wolfgang
    Schlemmer, Heinz-Peter
    Seitz, Angelika
    Bendszus, Martin
    RADIOLOGY, 2017, 283 (03) : 827 - 835
  • [33] INCREASED SIGNAL INTENSITY ON T1-WEIGHTED MR IMAGE OF PHYSIOLOGICAL INTRACRANIAL CALCIFICATIONS
    MICHAEL, AS
    PAIGE, ML
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1991, 15 (05) : 351 - 353
  • [34] High signal intensity of intervertebral calcified disks on T1-weighted MR images resulting from fat content
    Jacques Malghem
    Frédéric E. Lecouvet
    Robert François
    Bruno C. Vande Berg
    Thierry Duprez
    Guy Cosnard
    Baudouin E. Maldague
    Skeletal Radiology, 2005, 34 : 80 - 86
  • [35] High signal intensity of intervertebral calcified disks on T1-weighted MR images resulting from fat content
    Malghem, J
    Lecouvet, FE
    François, R
    Vande Berg, BC
    Duprez, T
    Cosnard, G
    Maldague, BE
    SKELETAL RADIOLOGY, 2005, 34 (02) : 80 - 86
  • [36] Radiation-induced brain calcification: Paradoxical high signal intensity in T1-weighted MR images - Comment
    Achten, E
    Backlund, EO
    ACTA NEUROCHIRURGICA, 2000, 142 (07) : 804 - 804
  • [37] No Signal Intensity Increase in the Dentate Nucleus on Unenhanced T1-weighted MR Images after More than 20 Serial Injections of Macrocyclic Gadolinium-based Contrast Agents
    Radbruch, Alexander
    Haase, Robert
    Kieslich, Pascal J.
    Weberling, Lukas D.
    Kickingereder, Philipp
    Wick, Wolfgang
    Schlemmer, Heinz-Peter
    Bendszus, Martin
    RADIOLOGY, 2017, 282 (03) : 699 - 707
  • [38] Posterior lobe of the pituitary gland: Correlation between signal intensity on T1-weighted MR images and vasopressin concentration
    Kurokawa, H
    Fujisawa, I
    Nakano, Y
    Kimura, H
    Akagi, K
    Ikeda, K
    Uokawa, K
    Tanaka, Y
    RADIOLOGY, 1998, 207 (01) : 79 - 83
  • [39] Reply to "T1-Weighted Signal-Intensity Ratio of Renal Hemorrhagic Cysts"
    McKee, Timothy C.
    Dave, Jaydev
    Kania, Leann
    Karajgikar, Jay
    Masarapu, Venkata
    Deshmukh, Sandeep
    Roth, Christopher
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (05) : W54 - W54
  • [40] Ratio of T1-Weighted to T2-Weighted Signal Intensity as a Measure of Tissue Integrity: Comparison with Magnetization Transfer Ratio in Patients with Multiple Sclerosis
    Pareto, D.
    Garcia-Vidal, A.
    Alberich, M.
    Auger, C.
    Montalban, X.
    Tintore, M.
    Sastre-Garriga, J.
    Rovira, A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2020, 41 (03) : 461 - 463