High-Pitch Electrocardiogram-Triggered Computed Tomography of the Chest Initial Results

被引:65
|
作者
Lell, Michael [1 ]
Hinkmann, Fabian [1 ]
Anders, Katharina [1 ]
Deak, Paul [2 ]
Kalender, Willi A. [2 ]
Uder, Michael [1 ]
Achenbach, Stephan [3 ]
机构
[1] Univ Erlangen Nurnberg, Dept Radiol, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
[3] Univ Erlangen Nurnberg, Dept Cardiol, D-91054 Erlangen, Germany
关键词
computed tomography; pulmonary embolism; aortic dissection; coronary CT angiography; dual source CT; radiation exposure; CORONARY CT ANGIOGRAPHY; TRIPLE RULE-OUT; DUAL-SOURCE CT; IMAGE QUALITY; NONCARDIAC FINDINGS; RADIATION-EXPOSURE; MULTISLICE CT; HEART-RATES; RECONSTRUCTION; PREVALENCE;
D O I
10.1097/RLI.0b013e3181b9df7e
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Chest pain is one of the most frequent symptoms in the emergency department. A variety of different diseases, some of them acutely life threatening, can be the underlying cause. Electrocardiogram (ECG)gated computed tomography angiography of the thorax has been proposed as a cost and time effective imaging technique for these patients. We describe a new high-pitch scan mode, which has been developed specifically for low-dose ECG-triggered computed tomography angiography using dual source computed tomography (CT). Material and Methods: Twenty-four patients were examined with this technique on a second generation dual source CT system. The scan mode uses a pitch of 3.2 to acquire a spiral CT data set of the complete thorax in less than I second with a temporal resolution of 75 ms (scan parameters: 128 X 0.6 mm collimation, 0.28 seconds gantry rotation time, 370 mAs at 100 kV [15 patients] and 320 mAs at 120 kV [9 patients], reconstructed slice thickness 0.6 mm, increment 0.4 mm). Data acquisition was prospectively triggered at 50% to 60% of the RR interval to cover the range over the heart in diastole. A triple phase contrast injection protocol (total volume: 80 mL) was used to optimize enhancement of the pulmonary and systemic arterial vessels. Image quality was evaluated using a 4-point scale (1 = absence of motion artifacts; 2 = slight motion artifacts, fully evaluable; 3 = motion artifacts, but evaluable; 4 = unevaluable) on a per-segment basis. Results: The patients had an average heart rate of 68 +/- 15 bpm (range: 43-111 bpm) during data acquisition. Motion artifact free visualization of the aorta and pulmonary vessels was possible in each case, of 344 coronary artery segments, 242 (70%) had an image quality score of 1, 60 segments (17%) a score of 2, 28 segments (8%) a score of 3, and 14 segments (4%) were rated as "unevaluable." In 17 patients (10 patients with a heart rate <= 60 bpm) all segments were evaluable. The average dose length product was 113 +/- 11 mGy x cm per scan (mean effective dose 1.6 +/- 0.2 mSv) at 100 kV and 229 +/- 31 mGy x cm per scan (mean effective dose 3.2 +/- 0.4 mSv) at 120 kV. Conclusion: Our initial results indicate that this high-pitch scan mode allows motion artifact free and accurate visualization of the thoracic vessels, and diagnostic image quality of the coronary arteries in patients with low and stable heart rates at a very low radiation exposure.
引用
收藏
页码:728 / 733
页数:6
相关论文
共 50 条
  • [21] Computed Tomography of the Lung in the High-Pitch Mode Is Breath Holding Still Required?
    Baumueller, Stephan
    Alkadhi, Hatem
    Stolzmann, Paul
    Frauenfelder, Thomas
    Goetti, Robert
    Schertler, Thomas
    Plass, Andre
    Falk, Volkmar
    Feuchtner, Gudrun
    Scheffel, Hans
    Desbiolles, Lotus
    Leschka, Sebastian
    INVESTIGATIVE RADIOLOGY, 2011, 46 (04) : 240 - 245
  • [22] Evaluation of High-Pitch Ungated Pediatric Cardiovascular Computed Tomography for the Assessment of Cardiac Structures in Neonates
    Sriharan, Mona
    Lazoura, Olga
    Pavitt, Christopher W.
    Castellano, Isabel
    Owens, Catherine M.
    Rubens, Michael B.
    Padley, Simon P. G.
    Nicol, Edward D.
    JOURNAL OF THORACIC IMAGING, 2016, 31 (03) : 177 - 182
  • [23] Radiation Dose and Image Quality of a High-Pitch Prospective Spiral First Approach in Coronary Computed Tomography Angiography (CCTA)
    Finck, Tom
    Klambauer, Konstantin
    Hendrich, Eva
    Will, Albrecht
    Martinoff, Stefan
    Hadamitzky, Martin
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2021, 8 (10)
  • [24] High-Pitch Photon-Counting Detector Computed Tomography Angiography of the Aorta Intraindividual Comparison to Energy-Integrating Detector Computed Tomography at Equal Radiation Dose
    Euler, Andre
    Higashigaito, Kai
    Mergen, Victor
    Sartoretti, Thomas
    Zanini, Bettina
    Schmidt, Bernhard
    Flohr, Thomas G.
    Ulzheimer, Stefan
    Eberhard, Matthias
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2022, 57 (02) : 115 - 121
  • [25] Detection of Coronary Artery Stenoses by Low-Dose, Prospectively ECG-Triggered, High-Pitch Spiral Coronary CT Angiography
    Achenbach, Stephan
    Goroll, Tobias
    Seltmann, Martin
    Pflederer, Tobias
    Anders, Katharina
    Ropers, Dieter
    Daniel, Werner G.
    Uder, Michael
    Lell, Michael
    Marwan, Mohamed
    JACC-CARDIOVASCULAR IMAGING, 2011, 4 (04) : 328 - 337
  • [26] Image Quality and Feasibility of an Ultralow-dose High-pitch Helical Triple-rule-out Computed Tomography Angiography Acquired in the Caudocranial Direction
    Kligerman, Seth J.
    White, Charles S.
    JOURNAL OF THORACIC IMAGING, 2014, 29 (01) : 50 - 59
  • [27] Navigation of lead extraction-is it possible? Impact of preprocedural electrocardiogram-triggered computed tomography on navigation of lead extraction
    Vogler, Julia
    Pecha, Simon
    Azarrafiy, Ryan
    Castro, Liesa
    Deuschl, Florian
    Spink, Clemens
    Linder, Matthias
    von Hehn, Ulrike
    Willems, Stephan
    Reichenspurner, Hermann
    Gosau, Nils
    Hakmi, Samer
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 54 (04) : 745 - 751
  • [28] Double prospectively ECG-triggered high-pitch spiral acquisition for CT coronary angiography: Initial experience
    Wang, Q.
    Qin, J.
    He, B.
    Zhou, Y.
    Yang, J-J
    Hou, X. -L.
    Yang, X. -B.
    Chen, J. -H.
    Chen, Y. -D.
    CLINICAL RADIOLOGY, 2013, 68 (08) : 792 - 798
  • [29] Optimizing Radiation Dose Levels in Prospectively Electrocardiogram-Triggered Coronary Computed Tomography Angiography Using Iterative Reconstruction Techniques: A Phantom and Patient Study
    Hou, Yang
    Zheng, Jiahe
    Wang, Yuke
    Yu, Mei
    Vembar, Mani
    Guo, Qiyong
    PLOS ONE, 2013, 8 (02):
  • [30] Diagnostic Value of Prospective Electrocardiogram-triggered Dual-source Computed Tomography Angiography for Infants and Children with Interrupted Aortic Arch
    Li, Hai-Ou
    Wang, Xi-Ming
    Nie, Pei
    Ji, Xiao-Peng
    Cheng, Zhao-Ping
    Chen, Jiu-Hong
    Xu, Zhuo-Dong
    CHINESE MEDICAL JOURNAL, 2015, 128 (09) : 1184 - 1189