Clustering and nearest neighbour distances in atom-probe tomography

被引:106
作者
Philippe, T. [1 ]
De Geuser, F. [3 ]
Duguay, S. [1 ]
Lefebvre, W. [1 ]
Cojocaru-Miredin, O. [1 ]
Da Costa, G. [1 ]
Blavette, D. [2 ]
机构
[1] Univ Rouen, GPM, CNRS, UMR 6634, F-76801 St Etienne De Rouvray, France
[2] Inst Univ France, Paris, France
[3] Inst Natl Polytech Grenoble, SIMaP, CNRS, UMR 5614, F-38402 St Martin Dheres, France
关键词
Atom-probe tomography; Clustering; Nearest neighbour distances; Statistics; LOCAL MAGNIFICATION; RECONSTRUCTION; ALLOYS;
D O I
10.1016/j.ultramic.2009.06.007
中图分类号
TH742 [显微镜];
学科分类号
摘要
The measurement of chemical composition of tiny clusters is a tricky problem in both atom-probe tomography experiments and atomic simulations. A new approach relying on the distribution of the first nearest neighbour (1NN) distances between solute atoms in the 3D space composed of A and B atoms was developed. This new approach, the 1NN method, is shown to be an elegant way to get the composition of tiny B-enriched clusters embedded in a random AB solid solution. The theoretical statistical distributions of first neighbour distances P(r) for both random solid solution and solute-enriched clusters finely dispersed in a depleted matrix are established. It is shown that the most probable distance of P(r) gives directly the phase composition. Applications of this model to both one-phase SiGe alloy and boron-doped silicon containing small clusters indicate that this new approach is quite reliable. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1304 / 1309
页数:6
相关论文
共 28 条
[1]  
[Anonymous], LECT NOTES MATH
[2]   A GENERAL PROTOCOL FOR THE RECONSTRUCTION OF 3D ATOM-PROBE DATA [J].
BAS, P ;
BOSTEL, A ;
DECONIHOUT, B ;
BLAVETTE, D .
APPLIED SURFACE SCIENCE, 1995, 87-8 (1-4) :298-304
[3]  
CAMUS E, 1994, Z METALLKD, V85, P378
[4]   Performance of an energy-compensated three-dimensional atom probe [J].
Cerezo, A ;
Godfrey, TJ ;
Sijbrandij, SJ ;
Smith, GDW ;
Warren, PJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (01) :49-58
[5]   Three-dimensional atomic-scale imaging of boron clusters in implanted silicon [J].
Cojocaru-Miredin, O. ;
Cadel, E. ;
Vurpillot, F. ;
Mangelinck, D. ;
Blavette, D. .
SCRIPTA MATERIALIA, 2009, 60 (05) :285-288
[6]   ATOM PROBE CHARACTERIZATION OF ISOTROPIC SPINODAL DECOMPOSITIONS - SPATIAL CONVOLUTIONS AND RELATED BIAS [J].
DANOIX, F ;
AUGER, P ;
BOSTEL, A ;
BLAVETTE, D .
SURFACE SCIENCE, 1991, 246 (1-3) :260-265
[7]   3D atom probe study of solute atoms clustering during natural ageing and pre-ageing of an Al-Mg-Si alloy [J].
De Geuser, F ;
Lefebvre, W ;
Blavette, D .
PHILOSOPHICAL MAGAZINE LETTERS, 2006, 86 (04) :227-234
[8]   An improved reconstruction procedure for the correction of local magnification effects in three-dimensional atom-probe [J].
De Geuser, F. ;
Lefebvre, W. ;
Danoix, F. ;
Vurpillot, F. ;
Forbord, B. ;
Blavette, D. .
SURFACE AND INTERFACE ANALYSIS, 2007, 39 (2-3) :268-272
[9]  
DEGEUSER F, 2005, U ROUEN
[10]   Design of a femtosecond laser assisted tomographic atom probe [J].
Gault, B ;
Vurpillot, F ;
Vella, A ;
Gilbert, M ;
Menand, A ;
Blavette, D ;
Deconihout, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (04)