Adaptive use of natural ventilation for thermal comfort in Indian apartments

被引:92
作者
Indraganti, Madhavi [1 ]
机构
[1] Jawaharlal Nehru Architecture & Fine Arts Univ, Dept Architecture, Hyderabad, Andhra Pradesh, India
关键词
Occupant behaviour; Thermal comfort field survey; Apartments in Hyderabad; Adaptive comfort model; Window opening; Restrained adaptive opportunity; FIELD; ENVIRONMENT; STANDARDS;
D O I
10.1016/j.buildenv.2009.12.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Thermal comfort research in India is in its nascent stage. Indian codes specify uniform comfort temperatures between 23 and 26 degrees C for all types of buildings. About 73% of energy in Indian residences is consumed for ventilation and lighting controls. Therefore, a thermal comfort field survey was conducted in apartment buildings in Hyderabad, which included information on the use of building controls. The present analysis is based on this database. Due to the poor availability of adaptive opportunities, 60% of the occupants were uncomfortable in summer. The comfort range obtained (26.0-32.5 degrees C was way above the standard. The occupants adapted through clothing, metabolism and the use of various controls like windows, balcony and external doors and curtains. The subjects operated the controls, as the indoor temperature moved away from the comfort band. At comfort temperature, maximum use of openings was found, which correlated robustly with indoor/outdoor temperature and thermal sensation. Use of controls was critically impeded by lack of privacy and safety and non-availability of controls. Several design and non-thermal factors, such as operation and maintenance of controls, mosquitoes, noise, and occupant's attitude, age and tenure impacted the occupant's adaptive behaviour and thermal comfort significantly. The building's 'restrained adaptive opportunity' seriously hampered the occupant's thermal satisfaction and adversely affected the sensation vote. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1490 / 1507
页数:18
相关论文
共 42 条
[1]   Survey of occupant behaviour and control of indoor environment in Danish dwellings [J].
Andersen, Rune Vinther ;
Toftum, Jorn ;
Andersen, Klaus Kaae ;
Olesen, Bjarne W. .
ENERGY AND BUILDINGS, 2009, 41 (01) :11-16
[2]  
[Anonymous], EN CONS BUILD COD 20
[3]  
[Anonymous], 1997, DEV ADAPTIVE MODEL T
[4]  
*ASHRAE INC, 2005, ASHRAE HDB FUND
[5]   Thermal comfort for free-running buildings [J].
Baker, N ;
Standeven, M .
ENERGY AND BUILDINGS, 1996, 23 (03) :175-182
[6]   Occupant comfort in UK offices - How adaptive comfort theories might influence future low energy office refurbishment strategies [J].
Barlow, Stuart ;
Fiala, Dusan .
ENERGY AND BUILDINGS, 2007, 39 (07) :837-846
[7]  
BIN S, 2008, 5 M JUN 23 2008 SEOU
[8]  
BIS, 2005, NAT BUILD COD
[9]  
Brager G.S., 2004, ASHRAE Transactions, V110, P17
[10]   Thermal comfort and behavioural strategies in office buildings located in a hot-arid climate [J].
Cena, K ;
de Dear, R .
JOURNAL OF THERMAL BIOLOGY, 2001, 26 (4-5) :409-414