Development of a 60 Hz power standard using SNS programmable Josephson voltage standards

被引:39
作者
Burroughs, Charles J., Jr. [1 ]
Benz, Samuel P.
Dresselhaus, Paul D.
Waltrip, B. C.
Nelson, T. L.
Chong, Yonuk
Williams, Jonathan M.
Henderson, Dale
Patel, Pravin
Palafox, Luis
Behr, Ralf
机构
[1] Natl Inst Stand & Technol, Boulder, CO 80305 USA
[2] Korea Res Inst Stand & Sci, Taejon 305340, South Korea
[3] Natl Phys Lab, Teddington TW11 0LW, Middx, England
[4] Phys Tech Lab, D-38116 Braunschweig, Germany
关键词
AC measurements; Josephson arrays; Josephson devices; Josephson voltage standard;
D O I
10.1109/TIM.2007.891156
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We are implementing a new standard for 60 Hz power measurements based on precision sinusoidal reference volt,ages from two independent programmable Josephson voltage standards (PJVS): one for voltage and one for current. The National Institute of Standards and Technology PJVS systems use series arrays of Josephson junctions to produce accurate quantum-based dc voltages. Using stepwise-approximation synthesis, the PJVS systems produce sinewaves with precisely calculable rms voltage and spectral content. We present measurements and calculations that elucidate the sources of error in the rms voltage that are intrinsic to the digital-synthesis technique and that are due to the finite rise times and transients that occur when switching between the discrete voltages. Our goal is to reduce all error sources and uncertainty contributions from the PJVS synthesized waveforms to a few parts in 10(7) so that the overall uncertainty in the ac-power standard is a few parts in 10(6).
引用
收藏
页码:289 / 294
页数:6
相关论文
共 14 条
[1]   Synthesis of precision waveforms using a SINIS Josephson junction array [J].
Behr, R ;
Williams, JA ;
Patel, P ;
Janssen, TJBM ;
Funck, T ;
Klonz, M .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2005, 54 (02) :612-615
[2]  
BEHR R, 2005, P 6 INT SEM EL METR, P11
[3]   Application of the Josephson effect to voltage metrology [J].
Benz, SP ;
Hamilton, CA .
PROCEEDINGS OF THE IEEE, 2004, 92 (10) :1617-1629
[4]   Stable 1 volt programmable voltage standard [J].
Benz, SP ;
Hamilton, CA ;
Burroughs, CJ ;
Harvey, TE ;
Christian, LA .
APPLIED PHYSICS LETTERS, 1997, 71 (13) :1866-1868
[5]  
BENZ SP, 2007, IEEE T INSTRUM MEAS
[6]   Flexible cryo-packages for Josephson devices [J].
Burroughs, CJ ;
Benz, SP ;
Dresselhaus, PD ;
Chong, Y ;
Yamamori, H .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (02) :465-468
[7]   Thermoelectric transfer difference of thermal converters measured with a Josephson source [J].
Burroughs, CJ ;
Benz, SP ;
Hamilton, CA ;
Harvey, TE ;
Kinard, JR ;
Lipe, TE ;
Sasaki, H .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (02) :282-284
[8]   Practical high-resolution programmable Josephson voltage standards using double- and triple-stacked MOSi2-barrier junctions [J].
Chong, Y ;
Burroughs, CJ ;
Dresselhaus, PD ;
Hadacek, N ;
Yamamori, H ;
Benz, SP .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (02) :461-464
[9]   Fast reversed DC measurements on thermal converters using a SINIS Josephson junction array [J].
Funck, T ;
Behr, R ;
Klonz, M .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2001, 50 (02) :322-325
[10]   JOSEPHSON D/A CONVERTER WITH FUNDAMENTAL ACCURACY [J].
HAMILTON, CA ;
BURROUGHS, CJ ;
KAUTZ, RL .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1995, 44 (02) :223-225