Evaluation of differences in Intraocular Pressure (IOP) measurement between Tonoref III and Goldmann Applanation Tonometry (GAT)

被引:0
|
作者
Lazari, Katerina C. [1 ]
Karpathaki, Margarita N. [1 ]
Linardakis, Manolis [2 ]
Christodoulakis, Emmanouil V. [1 ]
机构
[1] Rethymno Gen Hosp, Ophthalmol, Rethimnon, Greece
[2] Univ Crete, Fac Med, Dept Social Med, Iraklion, Greece
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
2420
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Inter-optometrist and intra-optometrist agreement for Intraocular Pressure (IOP) measurement by Goldmann Applanation Tonometry (GAT)
    Shah, Rakhee
    Edgar, David
    Campbell, Peter
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [2] Comparison of intraocular pressure measurement by Dynamic Contour Tonometry and Goldmann applanation tonometry
    DeBry, PW
    Krishna, R
    Willoughby, TL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U372 - U372
  • [3] Intraocular pressure measurement - Comparison of dynamic contour tonometry and Goldmann applanation tonometry
    Schneider, E
    Grehn, F
    JOURNAL OF GLAUCOMA, 2006, 15 (01) : 2 - 6
  • [4] Methods for Intraocular Pressure Measurement: Evaluation of Agreement Between Goldmann Applanation Tonometry and Goldmann Correlated Intraocular Pressure With Reichert's Ocular Response Analyzer
    Fraser, C. E.
    Ehrlich, J. R.
    Haseltine, S. J.
    Shimmyo, M.
    Radcliffe, N. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [5] Clinical differences in rebound tonometry and Goldmann applanation tonometry measurements of intraocular pressure in adult patients
    Chiu, Zelia
    Collins, Camille
    van der Straaten, David
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 50 (08): : 923 - 924
  • [6] Evaluating Goldmann Applanation Tonometry Intraocular Pressure Measurement Agreement Between Ophthalmic Technicians and Physicians
    Mihailovic, Aleksandra
    Varadaraj, Varshini
    Ramulu, Pradeep Y.
    Friedman, David S.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 219 : 170 - 176
  • [7] 24-hour intraocular pressure (IOP) monitoring with Goldmann applanation (GAT) tonometry and Tono-Pen AVIA® in keratoconic eyes.
    Merula, Rafael Vidal
    Cronemberger, Sebastiao
    Veloso, Artur C.
    Diniz-Filho, Alberto
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [8] Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients
    Tan, Shaoying
    Yu, Marco
    Baig, Nafees
    Hansapinyo, Linda
    Tham, Clement C.
    SCIENTIFIC REPORTS, 2017, 7
  • [9] Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients
    Shaoying Tan
    Marco Yu
    Nafees Baig
    Linda Hansapinyo
    Clement C. Tham
    Scientific Reports, 7
  • [10] The influence of refractive errors on IOP measurement by rebound tonometry (ICare) and Goldmann applanation tonometry
    Avitabile, Teresio
    Longo, Antonio
    Rocca, Daniela
    Amato, Roberta
    Gagliano, Caterina
    Castaing, Marine
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (04) : 585 - 591