A 1-Step Bayesian Predictive Approach for Evaluating In Vitro In Vivo Correlation (IVIVC)

被引:3
作者
Gould, A. Lawrence [1 ]
Agrawal, Nancy G. B. [1 ]
Goel, Thanh V. [2 ]
Fitzpatrick, Shaun [1 ]
机构
[1] Merck Res Labs, N Wales, PA 19454 USA
[2] Merial Ltd, Duluth, GA 30096 USA
关键词
prediction; bioavailability; pharmacokinetic; EXPLORATORY DATA-ANALYSIS; MODEL-DEPENDENT APPROACH; DRUG-RELEASE; DISSOLUTION; DECONVOLUTION; CONVOLUTION; FORMULATION; LEVEL; TIME; FIT;
D O I
10.1002/bdd.672
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
IVIVC (in vitro in vivo correlation) methods may support approving a change in formulation of a drug using only in vitro dissolution data without additional bioequivalence trials in human subjects. Most current IVIVC methods express the in vivo plasma concentration of a drug formulation as a function of the cumulative in vivo absorption. The absorption is not directly observable, so is estimated by the cumulative dissolution of the drug formulation in in vitro dissolution trials. The calculations conventionally entail the complex and potentially unstable mathematical operations of convolution and deconvolution, or approximations aimed at omitting their need. This paper describes, and illustrates with data on a controlled-release formulation, a Bayesian approach to evaluating IVIVC that does not require convolution, deconvolution or approximation. This approach incorporates between- and within-subject (or replicate) variability without assuming asymptotic normality. The plasma concentration curve is expressed in terms of the in vitro dissolution percentage instead of time, recognizing that this correspondence may be noisy because of the various sources of error. All conventional functions of the concentration curve Such as AUC, C(max) and T(max) can be expressed in terms of dissolution percentage, with uncertainties arising from variability in measuring absorption and dissolution accounted for explicitly. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:366 / 388
页数:23
相关论文
共 31 条
[1]   Statistical assessment of dissolution and drug release profile similarity using a model-dependent approach [J].
Berry, Mark R. ;
Likar, Michael D. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 45 (02) :194-200
[2]   Direct, differential-equation-based in-vitro-in-vivo correlation (IVIVC) method [J].
Buchwald, P .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 2003, 55 (04) :495-504
[3]   Comparison of dissolution profiles of Ibuprofen pellets [J].
Costa, FO ;
Sousa, JJS ;
Pais, AACC ;
Formosinho, SJ .
JOURNAL OF CONTROLLED RELEASE, 2003, 89 (02) :199-212
[4]  
Dunne A, 1999, STAT MED, V18, P1865, DOI 10.1002/(SICI)1097-0258(19990730)18:14<1865::AID-SIM223>3.0.CO
[5]  
2-P
[6]  
Dunne A, 1997, ADV EXP MED BIOL, V423, P67
[7]   The relationship between in vitro drug dissolution and in vivo absorption [J].
Dunne, A ;
Devane, J ;
O'Hara, T .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1999, 48 :125-133
[8]   Level A in vitro in vitro correlation:: Nonlinear models and statistical methodology [J].
Dunne, A ;
O'Hara, T ;
Devane, J .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1997, 86 (11) :1245-1249
[9]  
*EUR AG EV MED PRO, 1999, NOT GUID QUAL MOD RE
[10]  
*FDA, 1997, GUID IND EXT REL OR