Clinical evaluation of TOF versus non-TOF on PET artifacts in simultaneous PET/MR: a dual centre experience

被引:16
作者
ter Voert, Edwin E. G. W. [1 ,2 ]
Veit-Haibach, Patrick [1 ,2 ,3 ]
Ahn, Sangtae [4 ]
Wiesinger, Florian [5 ]
Khalighi, M. Mehdi [6 ]
Levin, Craig S. [7 ]
Iagaru, Andrei H. [8 ]
Zaharchuk, Greg [9 ]
Huellner, Martin [1 ,2 ,10 ]
Delso, Gaspar [6 ]
机构
[1] Univ Hosp Zurich, Dept Nucl Med, Ramistr 100, CH-8091 Zurich, Switzerland
[2] Univ Zurich, Zurich, Switzerland
[3] Univ Hosp Zurich, Dept Diagnost & Intervent Radiol, Zurich, Switzerland
[4] GE Global Res, Niskayuna, NY USA
[5] GE Global Res, Munich, Germany
[6] GE Healthcare, Waukesha, WI USA
[7] Stanford Univ, Dept Radiol, Mol Imaging Program Stanford, Stanford, CA 94305 USA
[8] Stanford Univ, Dept Radiol, Div Nucl Med & Mol Imaging, Stanford, CA 94305 USA
[9] Stanford Univ, Dept Radiol, Neuroradiol, Stanford, CA 94305 USA
[10] Univ Hosp Zurich, Dept Neuroradiol, Zurich, Switzerland
关键词
Time-of-flight; Artifacts; Positron emission tomography; Magnetic resonance imaging; Clinical research; TIME-OF-FLIGHT; ATTENUATION CORRECTION; WHOLE-BODY; IMAGE-RECONSTRUCTION; EMISSION; INFORMATION; SEGMENTATION; SYSTEM; METAL; TOMOGRAPHY;
D O I
10.1007/s00259-017-3619-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our objective was to determine clinically the value of time-of-flight (TOF) information in reducing PET artifacts and improving PET image quality and accuracy in simultaneous TOF PET/MR scanning. A total 65 patients who underwent a comparative scan in a simultaneous TOF PET/MR scanner were included. TOF and non-TOF PET images were reconstructed, clinically examined, compared and scored. PET imaging artifacts were categorized as large or small implant-related artifacts, as dental implant-related artifacts, and as implant-unrelated artifacts. Differences in image quality, especially those related to (implant) artifacts, were assessed using a scale ranging from 0 (no artifact) to 4 (severe artifact). A total of 87 image artifacts were found and evaluated. Four patients had large and eight patients small implant-related artifacts, 27 patients had dental implants/fillings, and 48 patients had implant-unrelated artifacts. The average score was 1.14 +/- 0.82 for non-TOF PET images and 0.53 +/- 0.66 for TOF images (p < 0.01) indicating that artifacts were less noticeable when TOF information was included. Our study indicates that PET image artifacts are significantly mitigated with integration of TOF information in simultaneous PET/MR. The impact is predominantly seen in patients with significant artifacts due to metal implants.
引用
收藏
页码:1223 / 1233
页数:11
相关论文
共 53 条
[21]   PET/MR imaging of the pelvis in the presence of endoprostheses: reducing image artifacts and increasing accuracy through inpainting [J].
Ladefoged, Claes Nohr ;
Andersen, Flemming Littrup ;
Keller, Sune Hogild ;
Lofgren, Johan ;
Hansen, Adam Espe ;
Holm, Soren ;
Hojgaard, Liselotte ;
Beyer, Thomas .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (04) :594-601
[22]  
Levin C., 2013, Soc. Nucl. Med. Annu. Meet. Abstr, V54, P148
[23]   An Assessment of the Impact of Incorporating Time-of-Flight Information into Clinical PET/CT Imaging [J].
Lois, Cristina ;
Jakoby, Bjoern W. ;
Long, Misty J. ;
Hubner, Karl F. ;
Barker, David W. ;
Casey, Michael E. ;
Conti, Maurizio ;
Panin, Vladimir Y. ;
Kadrmas, Dan J. ;
Townsend, David W. .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (02) :237-245
[24]   Tissue Classification as a Potential Approach for Attenuation Correction in Whole-Body PET/MRI: Evaluation with PET/CT Data [J].
Martinez-Moeller, Axel ;
Souvatzoglou, Michael ;
Delso, Gaspar ;
Bundschuh, Ralph A. ;
Chefd'hotel, Christophe ;
Ziegler, Sibylle I. ;
Navab, Nassir ;
Schwaiger, Markus ;
Nekolla, Stephan G. .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (04) :520-526
[25]   MR constrained simultaneous reconstruction of activity and attenuation maps in brain TOF-PET/MR imaging [J].
Abolfazl Mehranian ;
Habib Zaidi .
EJNMMI Physics, 1 (Suppl 1)
[26]   Emission-based estimation of lung attenuation coefficients for attenuation correction in time-of-flight PET/MR [J].
Mehranian, Abolfazl ;
Zaidi, Habib .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (12) :4813-4833
[27]   Clinical Assessment of Emission- and Segmentation-Based MR-Guided Attenuation Correction in Whole-Body Time-of-Flight PET/MR Imaging [J].
Mehranian, Abolfazl ;
Zaidi, Habib .
JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (06) :877-883
[28]   Improvement of Attenuation Correction in Time-of-Flight PET/MR Imaging with a Positron-Emitting Source [J].
Mollet, Pieter ;
Keereman, Vincent ;
Bini, Jason ;
Izquierdo-Garcia, David ;
Fayad, Zahi A. ;
Vandenberghe, Stefaan .
JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (02) :329-336
[29]   Simultaneous MR-Compatible Emission and Transmission Imaging for PET Using Time-of-Flight Information [J].
Mollet, Pieter ;
Keereman, Vincent ;
Clementel, Enrico ;
Vandenberghe, Stefaan .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (09) :1734-1742
[30]   Recent advances and future advances in time-of-flight PET [J].
Moses, William W. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02) :919-924