Using direct antiglobulin test results to reduce unnecessary cold agglutinin testing
被引:10
|作者:
Wilen, Craig B.
[1
]
Booth, Garrett S.
[2
]
Grossman, Brenda J.
[1
]
Lane, William J.
[3
,4
]
Szklarski, Penny C.
[2
]
Jackups, Ronald, Jr.
[1
]
机构:
[1] Washington Univ, Sch Med, Dept Pathol & Immunol, St Louis, MO USA
[2] Vanderbilt Univ, Med Ctr, Dept Pathol, Nashville, TN 37232 USA
[3] Brigham & Womens Hosp, Dept Pathol, 75 Francis St, Boston, MA 02115 USA
[4] Harvard Med Sch, Boston, MA USA
来源:
关键词:
AUTOIMMUNE HEMOLYTIC-ANEMIA;
ANTIBODY;
D O I:
10.1111/trf.14059
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
BACKGROUNDCold agglutinin disease (CAD) is a rare autoimmune hemolytic anemia mediated by autoantibodies that preferentially react at 4 degrees C. Laboratory testing for cold-reactive autoantibodies is laborious and may not be ordered judiciously, particularly in patients with a negative direct antiglobulin test (DAT). We sought to determine whether a negative DAT using anti-human complement (anti-C3) rules out elevated cold agglutinin (CA) titers and the diagnosis of CAD. STUDY DESIGN AND METHODSWe performed a retrospective study of patients with a CA test performed at three major academic medical centers: Barnes-Jewish Hospital (2003-2014), Vanderbilt University Medical Center (2007-2009), and Massachusetts General Hospital (2009-2014). RESULTSThis study included 801 patients, of whom 51% (n=410) had a DAT within the 7days before CA testing. A total of 98% of patients with a negative DAT using anti-C3 had a negative CA titer (<64). Only five subjects had a negative DAT using anti-C3 and an elevated CA titer. CONCLUSIONSOverutilization of CA testing could be reduced by establishing laboratory acceptance criteria based on a positive DAT using anti-C3. Such acceptance criteria would have reduced CA testing by 68% for those with an available DAT result.
引用
收藏
页码:1480 / 1484
页数:5
相关论文